Loading...
HomeMy WebLinkAbout2215 Sweetwater Creek Dr - Miscellaneous - 01/01/2000Fort Collins residential energy code 7/96 Mechanical systems disclosure form FES 12 RECD Job address: General contractor: Mechanical contractor: Space heating system Location Fuel Tvoe Manufacturer Model # Input capacity kBtuh or kW AFUE or HSPF ERASE= GAS F A37 D7 Space cooling system Location Fuel T e Manufacturer Model # Input capacity kBtuh or kW SEER GAS F/A ^ Water heating system. r d Location Fuel Tvae ( Manufacturer I Model # Inputcapacity I kBtuh or kW f Energy I Factor Storage I volume Certification INVe certify that the above -listed equipment was installed in the building at the above locations in conformance with the current requirements of the City of Fort Collins Residential Energy Code and Mechanical Code, and that it was installed in accordance with manufacturer's instructions. INVe certify that any ductwork has been installed in conformance with the current requirements of the City of Fort Collins Residential Energy Code and Mechanical Code. Certified by: ROBERT R MILLER Phone: (970) 223-8873 Business firrnNORTHE , COLORADO AIR, INC.Date: dt Address:1823 E HARMONY RD Signature: Instructions This disclosure form is to be signed by the mechanical contractor or representative of the general contractor. Please type or print, except for the signature. If there are multiple systems serving any function, make multiple entries to describe them. One copy of this form shall be provided to the Building and Zoning Department at final inspection. One copy of this form shall be provided to the homebuyer menmscWISS-3 — Ga4r6 Fort Collins Residential Energy Code the building & zoning dept. of AIR SEALING DISCLOSURE FORM Community Planning and Environmental Service 4d,d$c2m-7nOft 281 N. College Ave., P.O. Box 580, Fort Collins, CO 80522 (Not applicable to E-STAR or ENERGY SCORE rated homes) Voice: 970 221 6760 FAX: 970 224 6134 Job address: aaj j Lw e General contractor: 1-EA riijizn Air sealing contractor: 'T41P-V- vu Instructions; Complete either Part A or Part B . Part A is to be signed by the air sealing contractor or representative of the general contractor. Part B is to be signed by the blower door testing contractor or representative of the general contractor The "Blower Door Test Report" or equivalent documentation must be attached. Please type or print, except for the signature. If components vary, make multiple entries to describe them. One copy of this form must be provided to the Building and Zoning Department prior to C. O. One copy of this form must be provided to the original home buyer. .................................. A. Prescriptive path (Air Sealing; Checklist) Me certify that the air sealing requirements specified in the current City of Fort Collins Residential Energy Code have been completed in this building, in accordance with the "Air Sealing Checklist" published by the City of Fort Collins. Person Certifying Job: Si Date: Me certify that this building has met the air leakage performance threshold specified in the current Fort Collins Residential Energy Code, in accordance with the "Blower Door Test Procedures" published by the City of Fort Collins. Testing contractor: Date of test: CFM50: Volume: ACH50: Person Certifying Job: Air flow through the blower door at 50 Pascals pressure difference (cfm) Volume of home (cu. it) Air change rate per hour at 50 Pascals pressure difference ACH50 = (CFM50 x 60) / Volume The performance threshold for code compliance is ACH50 not exceeding 5.0 ac/h Signature: Date: Business Firm: Address: PhnnP-