Loading...
HomeMy WebLinkAbout2127 Ford Ln - Disclosures/Final Energy - 10/20/2001Oct 21 01 08:16p SRRR (9701 266 - 1009 p.2 Sara's Energy Scoring 1225 w. Prospect P-14 DATE FT. COLLINS, CO 80526 10/20/01 (970)495-9922 CUSTOMER-;- Peke Sherman 2127 Ford Ln Ft.- Collins- CO- BUILDING CONDITIONS: Interior Temp = 68 F Exterior Temp = 54 F Volume = 23200 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 59 125 1944 0.9 Ring A 52 96 1706 -2.8 Ring A 42 77 1530 2.2 Ring A 33 51 1247 -0.3 Ring A 28 41 1120 1.1 Ring A 21 25 877 -2.0 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9970 C = 93.02 n = 0.743 Results: Air Flow @ 50 Pascals : = 1703 CFM50 +/- 1.0% 4.41 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 73.89 Square Inches +/- 7.0% Equivalent Leakage Area (CANADA) = 151.25 Square Inches +/- 4.4% Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) = 126 CFM = 62.8 CFM/OCCUPANT s 0.32 AIR CHANGES PER HOUR 1