HomeMy WebLinkAbout3726 Manhattan Ave - Special Inspections/Engineering - 09/10/2001North Howes
Fort Collins, Colorado 80521
For
Herracon
Phone: (970) 484-0359
Fax: (970) 484-0454
SUMMARY QF REINFORCING STEEL
OBSER�/ATION
Client Name and Bellisimo Construction, Inc.
Project No.:
20011160
Address: Attn: Gino Campana
7307 Streamside Drive
Date:
9/10/01
Fort Collins, CO 80525
Report No.:
3
Project Name Park South Commercial Plaza
and Location: Horsetooth & Manhattan
Technician:
Richard Hoskinson
Fort Collins, Colorado
Reviewed By:
Mike L. Walker
Structure/Location Observed:
Footing Slab Building #9
Specifications - Steel Grade: ❑ 40 ® 60 Reinforcing Cleanliness: ® Acceptable ❑ Unacceptable
Splicing - Specifications: 36 bar diameters Clearance and Cover: 3" earth
In -place Comoliance ® Plans Used ❑ Full-time Observation
1. Met project requirements when initially examined. ® Yes ❑ No ❑ Shop Drawings Used ® Part-time Observation
2. Met project requirements when re-examined. ❑ Yes ❑ No ® Contractor Advised
Reinforcing:
(4) #4 continuous
II Comments:
u Provide clearance from sand to steel
Remove large dirt clods where needed i
EXCEPTIONS NOTED BELOW