HomeMy WebLinkAbout124 W Magnolia St - Permits/Addition or Alteration - 08/29/197841
City of Fort Collins BUILDING INSPECTION DIVISION
APPLICATION FOR BUILDING PERMIT AND CERTIFICATE OF OCCUPANCY
TO BUILD, ALTER, REPAIR, ADD TO OR WRECK A BUILDING OR STRUCTURE >Q�O
(APPLICANT FILL IN THIS SECTION ONLY)
IR.< .5�i-re-et —CLASS OF WORK —
Building Address W. M s 6 NOG -IA-- `
New I II Demolish
�i
ia
Dote of Applcation eaL2 1971 Alteration I I Repair
Name ///%r �.FL�.
Addition I i I
Move
e
3
Mail Address a919baoi/A -
Use of Building remall4ve
SwIr4VIA4
O
11 � a
Ciry T. COZZZNf Cd LO Tel. No.4tJ2-Q Sr
Yf �T. s301
Size of Building Q/p�I• ���stt qr
S s Height S�rAr¢
NomryE�PgLD 7%P�iePS /N/[� W��%rQutaNER
No. Floccrrsss__A-a
No. Families /V A.
to
Address 3o k/ / a 71 AaA.
,A4M
Floor Typcilh -nAtAAD
Size of Basement I2.w lh
6
^/S
City LG /YVE� COLS
No. of Fireplaces A10AW
Size of Garage Ng9A/6'
0
City License No_UC (e f Tel. No?71-
S 317
No. Baths
Type of Heat /h % 17 Q
Fa7 /So •R r� t% ,t , JRNA
L�B/�ar�etaalersgiett��a
—SPECIFICATIONS—
— — FOUNDATION — —
Block //'�.
a
Subdivision
I Exterior (Interior or Piers
a
—
Material I eoac. I Coat .
0Width
6 Thickness oFooting � / 9'X / 5 %
a
Name of Planned Unit Dev:
BX I sr• Width of Foundation Wall I 16 XIS �•
Depth below fin, grade 1APPI(. J8 I
j
— — FRAMING — —
Maximum
Size
I Spacing I Span
(Circle Correct classification)
Girders T/N6rI
CON .
$ lT StAb
1. Type of Construction 1, 11, ill, IV, V
Ist
2. Fire Resistivity 1-Hr 2-Hr. 3-Hr. 4-Hr.
Joist, Fl.
foist, end FI.
3. Occupancy Group A, E, H, 1, M, R
Joist, Ceiling
AB
W Mengs
Division 1, 2, 3, 4, 5
Exterior Studs
15 TO
4. Use Zone R-E, R-L, RLP, RLM, R-M, R-H, R-P,
RMP, B-P, B-L, H-B, B-G C, I-L, I-G, I-P
Interior Studs
I n 6
a 5AA
S. Fire Zone 2 2, 3 . s B
Roof Rafters
.I�
TOTAL VALUE
Includes all subcontrocisi excludes land value.
C O R I N G --
Exterior Wall Roo .�.eJVL/(OA�
Valuation subject to approval of Building Inspector.
DESCRIPTION OF WORK
Interior Woll`) w eroo
gee/ GrABLE SdAPT FPaKf �fNff Te 8 'Ft. I hereby acknowledge that I have read this application
and state that the above is correct and agree to comply with
AGDA/EW 3"SFtoet Ay /NtTN4um)4 oil city ordinances and state laws regulating building con-
struction.
�G &L ,WAV-7ea E IF ;A Sfgnat�uJ��r��ej��aryy��o��wgner.rA.
_ ieC�voBcoct alus � /y/y,/(g fG0G.
j
Plan
T0 Check■■ No. Date Issued A//LIsG� 2 9
j��{
Y.Y 2 Z V 3 Bldg. Fee s IWNU0
VALUATION orrser en Fl
and Inspections V
Total 11063100
PLANNING AND ZONING INFORMATION
Type of Occupancy
Total Floor Area
// 333
No. of Stories -? Total Height - r..i
Plat File No."A ni'I'v 4rea of Lot yy nUh
Frontage Lan
New Construction Alter
Change of Occupancy from
To
r
4?6�!_ 1--3R�-
Oft -Street Parking ___ S_QL____.._____
(No. Cars)
Interior Lot ❑ ,
Corner Lot
Reversed Corner Lot
L]
i
a-
rc
�V
(0•)
ILL `
rn us
c
"J
Street�.Q�_17_Q11 Cn_.___J11LC1-�SiCt-r....
Approved Variance Reference
ZBA Case No. Date
BBA Case No. Date _
Approve : For the Chief Building Inspector
l
i