Loading...
HomeMy WebLinkAbout1719 Mathews St - Correspondence - 12/06/1999FOUNDATION 11 Consulting ENGINEERING 11 Engineers, Ltd. July 23, 1992 Commission No. 1204-11-01-01 Mr. Chris Ray C/o Desyn Homes 3555 Stamford Road, Ste 102 Fort Collins, CO 80525 RE: 1719 Mathews, Fort Collins, Colorado Dear Mr. Ray: we have visually inspected the residence at the above referenced location. The home consists of a porch on a crawlspace. Currently a covered porch separates the garage from the main structure. The roof system of the porch bears on the slab. No foundation wall has been provided for either the porch or garage. It is our understanding that the porch is to be enclosed and heated which by code requires a thirty (30) inch frost wall. The wall should be eight (8) inches thick x thirty (30) inches deep with one (1) f5 top and bottom. The foundation wall should extend at least. two (2) inches under the slab providing additional support for the slab edge as shown on the sketch below. The roof should be supported on the new wall. If y•?u h«ve any questione, pl Kevin W. Patterson, ..E. FOUNDATION SNGINEE:RiNG, ?C111) : s b 3 ee to call. p1lE P�j�f,!.r� i 9 23841 1 ENGIf LTD. ANAL 51�10* �• Ek1(�, FioFlit" �}t,lSlS" Sl�11E+ ziWj1* 100East3rdStred- Lovd*ud;Colorado8853r «: (300):"4-0138 a .J