Loading...
HomeMy WebLinkAbout1648 N College Ave - Special Inspections/Engineering - 11/02/1991M J Engineers, Inc. 2383 WEST 23RD CIRCLE GOLDEN, COLORADO 80401 (303) 233-2268 November 2, 1991 Norb Lukas 6970 Indian Peaks Trail Boulder, CD 80301 Re: wind load increase Burger King Restaurant Country Club Corners P.U.D. Fort Collins, CCU To Whom It May Concern, NOV 14 1991 8V LOBAR, WC I have reviewed the above noted structure for a wind load pressure created by a 100 mile per hour wind velocity. See the following calculations. P Ce Cq I qs C = 1.2 e C = 1.3 q I = 1.0 qs = 26 P = 1.20 .3)(1.0)(26) = 40.56#/sf The structure had originally been designed for 32#/sf by a California engineer/ architect and I increased the nailing of the plywood sheathing and also the size of nails from 8d to 10d. Although the wind pressure has increased appreciably it is my engineering opinion that the structure can take this increase in wind load. SincceeJrely' yours, Mel. John/son PE