HomeMy WebLinkAbout1414 Snipe Ln - Miscellaneous - 04/17/2001SARA'S ENERGY SCORING 1225 W Prospect P-14 DATE FT. COLLINS CO 80526 04/17/01 (970)495-9922 CUSTOMER: Rocky Mountain Cons. 1414 Snipe 44 . FORT COLLINS BUILDING CONDITIONS: Interior Temp = 66 F Volume = 31300 Cu. Ft. Number of Stories = 2 Wind Shield Factor = 1 Exterior Temp = 55 F Above Grade Surface Area = 0 Sq. Ft. Number of Occupants = 2 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 57 161 2210 0.5 Ring A 50 134 2018 -0.7 Ring A 39 100 1746 -0.3 Ring A 30 74 1504 0.5 Ring A 20 45 1176 0.2 Ring A 16 34 1024 -0.3 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9998 C = 194.85 n = 0.599 Results: Air Flow @ 50 Pascals : 213 CFMSQ- +/- 0-.3V 3.90 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 126.79 Square Inches +/- 1.5% Equivalent Leakage Area (CANADA) = 227.45 Square Inches +/- 0.9% Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) = 150 CFM = 74.9 CFM/OCCUPANT = 0.29 AIR CHANGES PER HOUR