Loading...
HomeMy WebLinkAbout5451 Golden Willow Dr - Disclosures/Final Energy - 11/18/1998City of Fort Collins ENERGY SCORE Home Energy Rating Program - Version 2.0.4 .1.7 ******************************************************************************* FINAL "' R ENERGY RATING RESULT SITE P �*" "c D S17 ******************************************************************************* Owner: KEM HOMES Address: 5451 Golden Willow Zip: 80525 Phone: 223-4900 Builder: KEM HOMES Model: 2580 Devel: Willow Springs Reference # Data File Run Date Year Built Rating Firm: Site Rater: Rating Date: 241057 A:545GOL.DAT 11-18-1998 1998 RICHMOND ASSOCIATES DONALD RICHMOND 11-19-98 ******************************************************************************* 1210RI[eye U10[*la: a (Least Efficient) *********** * G - 84 *********** G ---- I ---- I ---- I ---- I ---- I ---- I ---- I ---- I G-0 10 20 30 40 50 60 70 80 - 84 v v ---- I ---- 1 90 100 (Most Efficient) ******************************************************************************* This program is offered by the City of Fort Collins as an aid in comparing the energy efficiency of homes. The information provided does not constitute any warranty, express or implied, as to the presence or lack of energy features in this house, the heating fuel used in the house and its costs, or the actual energy consumption or performance of the house. City of Fort Collins ENERGY SCORE Home Energy Rating Program - Version 2.0.4 DETAILED ENERGY REPORT FOR RATED BUILDING Owner: KEM HOMES Address: 5451 Golden Willow Zip: 80525 Phone: 223-4900 Builder: KEM HOMES Model: 2580 Devel: Willow Springs BUILDING CHARACTERISTICS Conditioned Space Area: 3957 sq ft Total Glazing Area: 445 sq ft Air Infiltration Rate: 0.40 AC/h Eff. Thermal Capacity: 8550 Btu/F Util. of Direct Solar: 0.62 BUILDING ENERGY SUMMARY Reference #: 241057 Data File: A:545GOL.DAT Run Date: 11-18-1998 Year Built: 1998 Rating Firm: RICHMOND ASSOCIATES Site Rater: DONALD RICHMOND Rating Date: 11-19-98 ENERGY SCORE *********** * G - 84 *********** Load Efficiency Energy Consumed Fuel Cost Energy Cost ----------------- KBtu/sf % --------------- KBtu/sf MMBtu --------- $/MMBtu ----------- $/sf Gas Space Heat 18.2 80.0 22.8 90.1 4.24 0.10 Gas Water Heat 6.1 54.0 11.3 44.7 4.24 0.05 Building TOTAL 24.3 34.1 134.8 0.14 COMPONENT SUMMARY: SPACE HEATING Heat Loss Coeff Gross Heat Loss Useful Gains Net Heat Load --------------- Btu/hr-F --------------- % KBtu/sf ------------ °s KBtu/sf % ------------- KBtu/sf MMBtu Ceilings/Roofs 32.0 4 1.3 4 0.3 2 1.0 4.0 Frame Walls 138.0 19 5.4 16 0.5 5 5.0 19.6 Masonry Walls 6.6 1 0.3 1 0.0 0 0.2 0.9 Rim/Band Joists 17.3 2 0.7 2 0.0 0 0.7 2.7 Windows/Skylights 240.2 33 9.5 29 6.8 65 2.7 10.5 Sunspace - - - - - - - - Doors 13.9 2 0.6 2 0.0 0 0.6 2.2 Foundation Walls 53.4 7 2.1 6 0.0 0 2.1 8.3 Frame Floors 1.0 0 0.1 0 0.0 0 0.1 0.2 Slab Floors 34.0 5 1.3 4 0.0 0 1.3 5.3 Crawl Sp/Unht Bsmt - - - - - - - - Infiltration 191.2 26 7.5 23 0.0 0 7.5 29.8 Envelope TOTAL 727.6 100 28.7 86 7.6 72 21.1 83.5 Active Solar Spc Ht Internal Gains 0.0 0 2.9 28 -2.9 -11.4 Duct/Pipe Losses - - - - - - Furnace Losses 4.6 14 0.0 0 4.6 18.1 Space Heating TOTAL 33.2 100 10.5 100 22.8 90.1 COMPONENT SUMMARY: WATER HEATING Gas 11.3 KBtu/sf = 44.7 MMBtu Solar - - Water Heating TOTAL 11.3 KBtu/sf = 44.7 MMBtu ENERGY SCORE Data Listing Date: 11-18-1998 Input Worksheet: A:545GOL.WS Reference Number: 241057 1. GENERAL INFORMATION Property Owner's Name Property Address Zip Code Telephone Number(s) Home Builder's Name Model Name or Number Development Name Energy Rating Company Building Plan Rating: Energy Rater's Name Energy Rating Date Site Visit Rating: Energy Rater's Name Energy Rating Date `a 1 KEM HOMES 2 5451 Golden Willow 3 80525 4 223-4900 5 KEM HOMES 6 2580 7 Willow Springs 8 RICHMOND ASSOCIATES 9 DONALD RICHMOND 10 6-18-97 11 DONALD RICHMOND 12 11-19-98 BUILDING STRUCTURE Year Constructed 13 1998 Area of Conditioned Space (sq ft) 14 3957 Housing Type (1-5) 15 1 Apartment Only: Level Type (1-3) 16 0 Floors On or Above Grade (1-2) 17 2 Foundation Type(s) (1-7) 18 4 3. CEILINGS/ROOFS Ceiling/Roof Roof Entry Gross Area Insulation Ceiling Type Line # (sq ft) (R-Value) (1-2) [191 19a 1388 19b 40 19c 1 [201 20a 0 20b 0 20c 0 [211 21a 0 21b 0 21c 0 4. RIM AND BAND JOISTS Area Joist Location Joist Insulation (sq ft) (1-4) (R-Value) 22a 261 22b 1 22c 16 23a 53 23b 2 23c 13 S. FRAME OR BRICK VENEER WALLS Wall Entry Gross Area Wall Location Wall Insulation Line # (sq ft) (1-4) (R-Value) [241 24a 2222 24b 1 24c 16 [251 25a 340 25b 2 25c 13 [261 26a 0 26b 0 26c 0 [271 27a 0 27b 1 27c 0 ENERGY SCORE Data Listing Input Worksheet: A:545GOL.WS Date: 11-18-1998 Reference Number: 241057 6. MASONRY WALLS ABOVE GRADE Wall Entry Gross Area Const. Type Wall Location Wall Insulat Line # (sq ft) (1-4) (1-4) (R-Value) [281 28a 68 28b 1 28c 1 28d 13 [291 29a 11 29b 1 29c 2 29d 19 [301 30a 80 30b 1 30c 1 30d 13 7. WINDOWS (INCLUDING DOOR GLAZING) Area Orientation Glazing Type Wall Entry (sq ft) (1-6) (1-21) Line #(24-30) 31a 144.7 31b 3 31c 4 31d 24 32a 80.6 32b 1 32c 4 32d 24 33a 145.6 33b 3 33c 4 33d 24 34a 14.7 34b 3 34c 9 34d 30 35a 44.2 35b 1 35c 9 35d 30 36a 0 36b 0 36c 0 36d 0 37a 0 37b 0 37c 0 37d 24 38a 0 38b 0 38c 0 38d 24 Area Orientation (sq ft) (1-6) 39a 7.4 39b 5 40a 7.4 40b 1 41a 0 41b 0 42a 0 42b 0 8. SKYLIGHTS Pitch (?/12) 39c 8 40c 8 41c 0 42c 0 Glazing Type (1-21) 39d 4 40d 4 41d 0 42d 0 9. DOORS (OPAQUE DOOR AREAS ONLY) Roof Entry Line #(19-21 39e 19 40e 19 41e 19 42e 19 Area Door Insulation Storm Door Wall Entry (sq ft) (R-Value) (l.yes, 2.no) Line #(24-30) 43a 20 43b 4.4 43c 2 43d 24 44a 8.8 44b 1.7 44c 2 44d 24 45a 17.8 45b 1.7 45c 2 45d 25 ENERGY SCORE Data Listing Input Worksheet: A:545GOL.WS Date: 11-18-1998 Reference Number: 241057 10. FOUNDATION WALLS BELOW GRADE Construction Depth Type Length Below Grade Wall Location Wall Insulat (1-4) (ft) (ft) (1-2) (R-Value) 46a 1 46b 158 46c 7 46d 1 46e 13 47a 0 47b 0 47c 0 47d 0 47e 0 48a 0 48b 0 48c 0 48d 1 48e 0 11. FRAME FLOOR Floor Area Insulation Floor Location (sq ft) (R-Value) (1-3) 49a 31 49b 31.5 49c 3 50a 0 50b 0 50c 0 51a 0 51b 0 51c 0 12. SLAB FLOORS (ON OR BELOW GRADE) Exposed Floor Area Perimeter Perimeter Insulation (sq ft) (ft) (R-Value) 52a 1316 52b 158 52c 0 53a 0 53b 0 53c 0 Under Slab Depth Width of Insulation Insulation Below Grade Under Slab (R-Value) (ft) (ft) 52d 0 52e 7 52f 0 53d 0 53e 0 53f 0 13. INTERIOR FINISH Drywall Thickness (0.5 to 1 in.) 54 .5 Uncarpeted Floor Slab (l.yes, 2.no) 55 2 Uncarpeted Floor Slab Area (sq ft) 56 0 Uncarpeted Floor Slab Thickness (in.) 57 4 14. ADDITIONAL MASS Mass Type Mass Area Mass Thickness (1-3) (sq ft) (in.) 58a 0 58b 0 58c 0 59a 0 59b 0 59c 0 ENERGY SCORE Data Listing Date: 11-18-1998 Volume of Cond. Space (cubic ft) 60 32314 15. INFILTRATION Type of Infiltration Measurement (1-3) 61 1 6 Input Worksheet: A:545GOL.WS Reference Number: 241057 Infiltration Value (ACH or sq.in) .4 16. HEATING EQUIPMENT Heating Heating Electric System Type System AFUE Furnace Input Demand Control (1-7) (%) (1000's Btu/h) (l.yes, 2.no) 63 1 64 80 65 125 66 2 17. DUCTS AND PIPES Duct or Pipe Area in Attic above Insulation (sq ft) 67 0 Attic Duct Insulation (l.yes, 2.no) 68 2 Duct or Pipe Area in Crawl Space or Unheated Basement (sq ft) 69 0 Crawl Space or Unheated Basement Duct Insulation (l.yes, 2.no) 70 2 18. DOMESTIC HOT WATER Water Heater Type (1-4) 71 1 Water Heater Efficiency (%) 72 54