Loading...
HomeMy WebLinkAbout5302 Golden Willow Ct - Disclosures/Final Energy - 02/20/1999 (2)City of Fort Collins IIENERGY SCORE Home Energy Rating Program - Version 2.0.4 ******************************************************************************* ENERGY RATING RESULT ******************************************************************************* Owner: KEM HOMES Reference #: 241171 Address: 5302 GOLDEN WILLOW Data File: A:5302 GOL.DAT Zip: 80525 Run Date: 02-20-1999 Phone: 223-4900 Year Built: 1999 Builder: KEM HOMES Rating Firm: RICHMOND ASSOCIATES Model: 2580 Site Rater: DONALD RICHMOND Devel: Willow Springs Rating Date: 2-20-99 ******************************************************************************* ENERGY SCORE: *********** * G - 84 *********** G - 84 v v (Least ------------------------------------ I ---- I Efficient) G-0 10 20 30 40 50 60 70 80 90 100 (Most Efficient) ******************************************************************************* This program is offered by the City of Fort Collins as an aid in comparing the energy efficiency of homes. The information provided does not constitute any warranty, express or implied, as to the presence or lack of energy features in this house, the heating fuel used in the house and its costs, or the actual energy consumption or performance of the house. City of Fort Collins ENERGY SCORE Home Energy Rating Program - Version 2.0.4 DETAILED ENERGY REPORT FOR RATED BUILDING Owner: KEM HOMES Reference #: 241171 Address: 5302 GOLDEN WILLOW Data File: A:5302 GOL.DAT Zip: 80525 Run Date: 02-20-1999 Phone: 223-4900 Year Built: 1999 Builder: KEM HOMES Model: 2580 Devel: Willow Springs BUILDING CHARACTERISTICS Conditioned Space Area: 3957 sq ft Total Glazing Area: 446 sq ft Air Infiltration Rate: 0.40 AC/h Eff. Thermal Capacity: 8550 Btu/F Util. of Direct Solar: 0.62 BUILDING ENERGY SUMMARY Rating Firm: RICHMOND ASSOCIATES Site Rater: DONALD RICHMOND Rating Date: 2-20-99 ENERGY SCORE *********** * G - 84 *********** Load Efficiency Energy Consumed Fuel Cost Energy Cost ------- ---------- KBtu/sf % --------------- KBtu/sf MMBtu --------- $/MMBtu ----------- $/sf Gas Space Heat 18.2 80.0 22.8 90.1 4.24 0.10 Gas Water Heat 6.1 54.0 11.3 44.7 4.24 0.05 Building TOTAL 24.3 34.1 134.8 0.14 COMPONENT SUMMARY: SPACE HEATING Heat Loss Coeff Gross Heat Loss Useful Gains Net Heat Load --------------- Btu/hr-F --------------- a KBtu/sf ------------ o KBtu/sf °s ------------- KBtu/sf MMBtu Ceilings/Roofs 32.0 4 1.3 4 0.3 2 1.0 4.0 Frame Walls 138.0 19 5.4 16 0.5 5 5.0 19.6 Masonry Walls 6.6 1 0.3 1 0.0 0 0.2 0.9 Rim/Band Joists 17.3 2 0.7 2 0.0 0 0.7 2.7 Windows/Skylights 240.7 33 9.5 28 6.8 65 2.7 10.5 Sunspace - - - - - - - - Doors 13.9 2 0.6 2 0.0 0 0.6 2.2 Foundation Walls 53.4 7 2.1 6 0.0 0 2.1 8.3 Frame Floors 1.0 0 0.1 0 0.0 0 0.1 0.2 Slab Floors 34.0 5 1.3 4 0.0 0 1.3 5.3 Crawl Sp/Unht Bsmt - - - - - - - - Infiltration 191.2 26 7.5 23 0.0 0 7.5 29.8 Envelope TOTAL 728.0 100 28.7 86 7.6 72 21.1 83.5 Active Solar Spc Ht - - - - - - Internal Gains 0.0 0 2.9 27 -2.9 -11.4 Duct/Pipe Losses - - - - - - Furnace Losses 4.5 14 0.0 0 4.5 18.0 Space Heating TOTAL 33.3 100 10.5 100 22.8 90.1 COMPONENT SUMMARY: WATER HEATING Gas 11.3 KBtu/sf = 44.7 MMBtu Solar - - Water Heating TOTAL 11.3 KBtu/sf = 44.7 MMBtu ENERGY SCORE Data Listing Date: 02-20;-1999 Input Worksheet: A:5302 GOL.WS Reference Number: 241171 1. GENERAL INFORMATION Property Owner's Name Property Address Zip Code Telephone Number(s) Home Builder's Name Model Name or Number Development Name Energy Rating Company Building Plan Rating: Energy Rater's Name Energy Rating Date Site Visit Rating: Energy Rater's Name Energy Rating Date 1 KEM HOMES 2 5302 GOLDEN WILLOW 3 80525 4 223-4900 5 KEM HOMES 6 2580 7 Willow Springs 8 RICHMOND ASSOCIATES 9 DONALD RICHMOND 10 6-18-97 11 DONALD RICHMOND 12 2-20-99 2. BUILDING STRUCTURE Year Constructed Area of Conditioned Space (sq ft) Housing Type (1-5) Apartment Only: Level Type (1-3) Floors On or Above Grade (1-2) Foundation Type(s) (1-7) Roof Entry Line # [191 [201 [211 3. CEILINGS/ROOFS Gross Area (sq ft) 19a 1388 20a 0 21a 0 13 14 15 16 17 18 Ceiling/Roof Insulation (R-Value) 19b 40 20b 0 21b 0 1999 3957 1 0 2 4 Ceiling Type (1-2) 19c 1 20c 0 21c 0 4. RIM AND BAND JOISTS Area Joist Location Joist Insulation (sq ft) (1-4) (R-Value) 22a 261 22b 1 22c 16 23a 53 23b 2 23c 13 5. FRAME OR BRICK VENEER WALLS Wall Entry Gross Area Wall Location Wall Insulation Line # (sq ft) (1-4) (R-Value) [24) 24a 2222 24b 1 24c 16 [251 25a 340 25b 2 25c 13 [261 26a 0 26b 0 26c 0 [271 i 27a 0 27b 1 27c 0 ENERGY SCORE Data Listing Input Worksheet: A:5302 GOL.WS Date: 02-20-1999 Reference Number: 241171 6. MASONRY WALLS ABOVE GRADE Wall Entry Gross Area Const. Type Wall Location Wall Insulat Line # (sq ft) (1-4) (1-4) (R-Value) [281 28a 68 28b 1 28c 1 28d 13 [291 29a 11 29b 1 29c 2 29d 19 [301 30a 80 30b 1 30c 1 30d 13 7. WINDOWS (INCLUDING DOOR GLAZING) Area Orientation Glazing Type Wall Entry (sq ft) (1-6) (1-21) Line #(24-30) 31a 142.6 31b 3 31c 4 31d 24 32a 81.2 32b 1 32c 4 32d 24 33a 148.1 33b 3 33c 4 33d 24 34a 14.7 34b 3 34c 9 34d 30 35a 44.2 35b 1 35c 9 35d 30 36a 0 36b 0 36c 0 36d 0 37a 0 37b 0 37c 0 37d 24 38a 0 38b 0 38c 0 38d 24 Area (sq ft) 39a 7.4 40a 7.4 41a 0 42a 0 Orientation (1-6) 39b 5 40b 1 41b 0 42b 0 8. SKYLIGHTS Pitch (?/12) 39c 8 40c 8 41c 0 42c 0 Glazing Type (1-21) 39d 4 39e 40d 4 40e 41d 0 41e 42d 0 42e 9. DOORS (OPAQUE DOOR AREAS ONLY) Area Door Insulation Storm Door (sq ft) (R-Value) (1.yes, 2.no) 43a 20 43b 4.4 43c 2 43d 44a 8.8 44b 1.7 44c 2 44d 45a 17.8 45b 1.7 45c 2 45d Roof Entry Line #(19-21 19 19 19 19 Wall Entry Line #(24-30) 24 24 25 ENERGY SCORE Data Listing Input Worksheet: A:5302 GOL.WS Date: 02-20',1999 Reference Number: 241171 10. FOUNDATION WALLS BELOW GRADE Construction Depth Type Length Below Grade Wall Location Wall Insulat (1-4) (ft) (ft) (1-2) (R-Value) 46a 1 46b 158 46c 7 46d 1 46e 13 47a 0 47b 0 47c 0 47d 0 47e 0 48a 0 48b 0 48c 0 48d 1 48e 0 11. FRAME FLOOR Floor Area Insulation Floor Location (sq ft) (R-Value) (1-3) 49a 31 49b 31.5 49c 3 50a 0 50b 0 50c 0 51a 0 51b 0 51c 0 12. SLAB FLOORS (ON OR BELOW GRADE) Exposed Floor Area Perimeter Perimeter Insulation (sq ft) (ft) (R-Value) 52a 1316 52b 158 52c 0 53a 0 53b 0 53c 0 Under Slab Depth Width of Insulation Insulation Below Grade Under Slab (R-Value) (ft) (ft) 52d 0 52e 7 52f 0 53d 0 53e 0 53f 0 13. INTERIOR FINISH Drywall Thickness (0.5 to 1 in.) 54 .5 Uncarpeted Floor Slab (i.yes, 2.no) 55 2 Uncarpeted Floor Slab Area (sq ft) 56 0 Uncarpeted Floor Slab Thickness (in.) 57 4 14. ADDITIONAL MASS Mass Type Mass Area Mass Thickness (1-3) (sq ft) (in.) 58a 0 58b 0 58c 0 59a 0 59b 0 59c 0 ENERGY SCORE Data Listing Date: 02-20L1999 I Volume of Cond. Space (cubic ft) 60 32314 15. INFILTRATION Type of Infiltration Measurement (1-3) 61 1 62 Input Worksheet: A:5302 GOL.WS Reference Number: 241171 Infiltration Value (ACH or sq.in) 16. HEATING EQUIPMENT 0 Heating Heating Electric System Type System AFUE Furnace Input Demand Control (1-7) (%) (1000's Btu/h) (l.yes, 2.no) 63 1 64 80 65 100 66 2 17. DUCTS AND PIPES Duct or Pipe Area in Attic above Insulation (sq ft) 67 0 Attic Duct Insulation (l.yes, 2.no) 68 2 Duct or Pipe Area in Crawl Space or Unheated Basement (sq ft) 69 0 Crawl Space or Unheated Basement Duct Insulation (l.yes, 2.no) 70 2 18. DOMESTIC HOT WATER Water Heater Type (1-4) 71 1 Water Heater Efficiency (o) 72 54 I Fort Collins residentW energy Cade 7196 - ( �Anr7��rr:��7 r pc+F r e i.,w Job, ade----st Macnanical CJntMc!=i- Scacs heating system a. S.:zcs cacfing system lla==*atinc syszam Input ceac:ty I AFJc or kBtuh cr kW HE;:; Incut....caci`I I = ergy A•...^.e.^.. mas .nsmiled in the c �.� _.e at:-- lens in c_.. franc: mtC :Ze ---_..;e:•�_.n:en5 c.' :`.e C::y ci Fcr: =rr:s Resicercal =^.erry C� e :n : tAr-ari�i Gee, arc :tar:'. waz irsa�tec in wi^ anuiac•_rets irtS:LCc:s me cer—W / mat any •='r,crx has been insrdlec in nr harts W= _ .-et:._cuxerne. cf : e Cy d =_.. cc"r'ls nesieencai V •e'67 Cc_e anC Meananial Ca,._ Car'fied by: RCbe-- `?_" ;:6cre: 9 i 0-__3-88 i 3 Business trrn: yor_ie- Ca'crace_=, _cc::am: Address: 18213 = ca _c=7 3c- Signa=re: Ins; ucticns ...is •:.,ccswM fcr is to be signed byte mew apical d--n==r cr recrese^mve cf the generzi c nCaCt. ?:ease ype cr pr:Tt cccept 'Cr he sgnac:re. :':hen- are nuC` a sysams serving any fort--n, make rnt4ple en es W das�---e Ctem. Cre cpy cf pis ,`cn shad be prcviced tc te °udtrng and Zcning Oe_^a:.':ers az',ral inspeccn. Cne c.y cf ; is fen shad be provided L^ the hemetuyer.