HomeMy WebLinkAbout425 W Prospect Dr - Correspondence/Sprinkler - 04/05/2000APR-05-00 WED 08:38 AM Poudre Fire Authority FAX:970 221 6635 PAGE 4 Fire Prevention Bureau 102 Remington Street Fort Collins, CO 80524 To: Kevin Wilson From: Joe Jaramillo Re: University Park Holiday Inn Sprinkler System Phone:970-221-6570 Fax:970-221-6635 Internet•. wwwpoudre-fire.org R1 , A ear The University Park Holiday Inn was constructed in 1984. The 1993 edition of n1p.a. was used in the design of the sprinkler system. This edition of the handbook required that all canopies and covered docks needed sprinkler protection. Note: 4-4.10.2 Sprinklers shall be installed under exterior combustible roofs or canopies exceeding 4 ft in width. Fxcention: Sprinklers may be omitted where construction is noncombustible and areas under the canopies are not used for storage or handling. Exterior canopies exceeding 4 ft in width are to be sprinklered if combustible construction weather goods are stored or handled under it. If construction is non combustible and the area under is essentially restricted to pedestrian use, sprinklers may be omitted. The Holiday Inn entryway, is used for vehicle traffic therefore it is required to be sprinklered. In the 1987 edition of 13 section 4-4.10.2 the wording is the same except that automobiles stopping brie to pick up or droll o passengers would not be considered storage has been added. If the building was built using the sprinkler standards after the 1983 edition the canopy would not required sprinklers, APR-05-00 WED 08:38 AM Poudre Fire Authority FAX:970 221 6635 . 0 DVM Fort Collins University Park University Park Holiday Imt Go Mike Del Duca 425 W. Prospect 4sQ.- Ft. Collins, CO 80526 March 27, 2000 Poudre Fire Authority Attn: Joe Jaramillo 102 Remington Ft. Collins, Co PAGE 3 Dear Joe, I would like to requen that PFA would allow us to remove the existing sprinkler system from our front entrance awning. in January of 1999 the pressure valve tripped and released water into the lines. There was no warning that the valve tripped and when the litres thawed, it flooded the front enhance of the hotel. We replaced the valve and repaired the r water line that was broken. After starting the system back up, it was discovered that the I" Imes running through the awning were also bmken. To do the repairs we will have to pull the sheet rock down from the bottom of the awning. Besides the cost of the repairs, I am more concerned of the inconvenience to our guests for that 7 to 10 days of construction in our main entrance. Thanks for your consideration in this matter and I will await your decision. ii Duce Assistant General Manager University Park holiday Inn Phone (970) 462-2626 a 425 Went Prospect • Fort Collins, Colorado 60526 • Fax (970) 493-6265 Li,a,e,,, c,�iM"" ro Is