Loading...
HomeMy WebLinkAbout815 Snowy Plain Rd - Special Inspections/Engineering - 11/05/2009Irerracon November 5, 2009 Shadow Creek Homes 2861 W. 120"Avenue, Suite 240 Westminster. Colorado 80234 Attn: Mr. Toby Terhune Re: Foundation Footing Sizes, Wall Steel and CEE Observations Provincetowne Residential Development 815 Snowy Plain Road — Lot 3 Block 4 Fort Collins, Colorado Terracon Project No. 20075058 Dear Mr. Terhune: A representative from Terracon observed the interior and exterior foundation footing sizes and wall steel reinforcement, including the "concrete -encased electrode" (CEE), for the above referenced lot on October 21 and 23, 2009 as requested. Based upon our limited on -site observations, the foundations were constructed and the observed steel appeared to have been placed in general accordance with the provided plans and specifications. It should be noted that our observation services were performed on an as -requested basis, and only when requested by the above -listed client or their designated representative. Terracon's services do not include surveying of the locations or elevations of foundations elements. We offer no opinion regarding material and/or construction not observed by Terracon representatives. This letter is provided solely for the benefit for the above -listed client and does not impact in any way the rights and obligations of third parties, including contractors and subcontractors who may have provided the materials and/or construction services observed. Sincerely, Terracon Consultants, Inc. Craig L. Nelson Field Technician Copies to: Addressee (2) Joels C. Malama, P.E. "s Department Manager/Geotechnical Terracon Consultants, Inc. 301 North Howes Street - P [9701 484 0359 F [9701 484 0454 Fort Collins, Colorado 80521 terrecon.com 4218 . 11l5l09 Irerracon November 5, 2009 Shadow Creek Homes 2861 W. 120o' Avenue, Suite 240 Westminster, Colorado 80234 Attn: Mr. Toby Terhune Re: Foundation Damp -Proofing Observation Provincetowne Residential Development 815 Snowy Plain Road — Lot 3 Block 4 Fort Collins, Colorado Terracon Project No. 20075058 A representative of Terracon Consultants, Inc. (Terracon) performed a foundation damp -proofing observation at the subject site on October 28, 2009. The purpose of these services was to observe that damp -proofing was in locations of below grade basement foundation walls enclosing habitable space areas in general accordance with Foundation Damp -proofing, 2003 International Residential Code (IRC), Section R406. The observation did not include measurement of the coating thickness or determining the type of coating used. Based on our limited observation, the foundation damp -proofing appeared to have been applied in general accordance with the above mentioned standards. It should be noted that our observation services were performed on an as -requested basis, and only when requested by the above -listed client or their designated representative. We offer no opinion regarding materials and/or construction not observed by Terracon representatives. This letter is provided solely for the benefit for the above -listed client and does not impact in any way the rights and obligations of third parties, including contractors and subcontractors who may have provided the materials and/or construction services observed. Sincerely, Terracon Consultants, Inc. Craig L. Nelson Field Technician Copies to: Addressee (3) �. ... .. 42184 " •. 11J5P2009 < Joels C. Malama, P.E. Department Manager/Geotechnical Services Terracon Consultants, Inc. 301 North Howes Street Fort Collins, Colorado 80521 P [9701 484 0359 F [9701 484 0454 terracon.com Irerracon November 5, 2009 Shadow Creek Homes 2861 W. 120`n Avenue, Suite 240 Westminster. Colorado 80234 Attn: Mr. Toby Terhune Re: Exterior Perimeter Drain Observation Provincetowne Residential Development 815 Snowy Plain Road — Lot 3 Block 4 Fort Collins, Colorado Terracon Project No. 20075058 A representative of Terracon Consultants, Inc. (Terracon) observed the installed perimeter drain at the subject site on October 28, 2009. The purpose of these services was to: • Observe that properly sized pipe and gravel had been placed as recommended • Observe that the perimeter drain system had been placed at the locations recommended in the Geotechnical Engineering Report, Terracon Consultants, Inc. Project No. 20075058, dated November 5, 2007 Confirm that the perimeter drain system had been sloped to a sump pit for discharge Based upon our limited on -site observations, the observed drain appeared to have been constructed in general accordance with the provided plans and the referenced geotechnical engineering report. It should be noted that our observation services were performed on an as - requested basis, and only when requested by the above -listed client or their designated representative. We offer no opinion regarding materials and/or construction not observed by Terracon representatives. This letter is provided solely for the benefit for the above -listed client and does not impact in any way the rights and obligations of third parties, including contractors and subcontractors who may have provided the materials and/or construction services tested or observed. _<5ssyr. . Sincerely, Terracon Consultants, Inc. Craig L. Nelson Field Technician Copies to: Addressee (3) 42184 " 70 =•• nisrzoas r�< �F .... •. �.� Joels C. Malama, P.E. 11 Department Manager/ Geotechnical Terracon Consultants, Inc. 301 North Hawes Street P (9701 484 0359 F [9701 484 0454 Fort Collins, Colorado 80521 terrecon.com