Loading...
HomeMy WebLinkAbout2155 Orchard Pl - Disclosures/Air Sealing - 02/20/2009Fort Collins Residential Energy Code AIR SEALING DISCLOSURE FORM air&=2xs — 711 ores (Not applicable to E-STAR or ENERGY SCORE rated homes) Job address: RCAA the building & zoning dept. of Community Planning and Environmental Service 281 N. College Ave., P.O. Box 580, Fort Collins, CO 80522 Voice: 970 221 6760 FAX: 970 224 6134 General contractor:-726KI-WE ;E i0i lders v Air sealing contractor: INSTRUCTIONS Complete either Part A or Part B Part A is to be signed by the air sealing contractor or representative of the general contractor. Part B is to be signed by the blower door testing contractor or representative of the general contractor. The "Blower Door Test Report" or equivalent documentation must be attached. Please type or print, except for the signature. If components vary, make multiple entries to describe them. One copy of this form must be provided to the Building and Zoning Department prior to C. O. One copy of this form must be provided to the original home buyer. ► 'e-escr�t've tar' Saal�rafieckst UWe certify that the air sealing requirements speed in the current City of Fort Collins Residential Energy Code have been completed in'this.building, in accordance with the "Air Sealing Checklist' published by the City of Fort Collins Person Certifying Job: Signature: Date: Business Firm: Address: Phone: P+erero:eH. Xv I/We certify that this building has met the air leakage performance threshold specified in the current Fort Collins Residential Energy Code, in accordance with the "Blower Door Test Procedures" published by the City of Fort Collins. Testing contractor: Date of test: d2ap-pq CFM50: / %Q2�/ Air flow through the blower door at 50 Pascals pressure difference (cfm) Volume: /3334 Volume of home (cu. ft.) ACH50: 4/, 9� Air change rate per hour at 50 Pascals pressure difference ACH50 = (CFM50 x 60) / Volume The performance threshold for code compliance is ACH50 not exceeding 5.0 acth Person Certifying Job: gal 14igrn4n NJ Signature: Date: �U- Business Firm: r Address: P6. Phone: y77�2 aa:�_ �o�o BUILDING LEAKAGE TEST Thermal Concepts P.O. Box 270066 Ft. Collins, CO 80527 Phone: 970-223-7090 Fax: 970-223-7098 Date of Test: 2-20-09 Technician: Paul Higman Test File: Treeline 2155 Orchard PI Bid L Customer. Treeline Builders Building Address: 2155 Orchard PI 2519 S. Shields #127 Bldg IL Ft. Collins, CO 80526 Ff. Collins, CO 80521 Phone 970-221-1567 Fax 970-221-1561 Test Results 1. Airflow at 50 Pascals: 1102 CFM (+/- 0.8 %) (50 Pa = 0.2 w.c.) 4.96 ACH 0.76 CFM per ft2 floor area 2. Leakage Areas: 74.2 in2 (+/- 7.8 %) Canadian EgLA @ 10 Pa 30.9in2 (+/-12.6%o)LBLELA@4Pa 3. Minneapolis Leakage Ratio: 4. Building Leakage Curve: Flow Coefficient (C) = 30.6 (+/-19.8 %) Exponent (n) = 0.916 (+/- 0.052. ) Correlation Coefficient = 0.99839 5. Test_ Settings: Test Standard: = CGSB Test Mode: = Depressurization Equipment =. Model 3 Minneapolis, Blower Door Infiltration Estimates 1: Estimated Average Annual Infiltration Rate:. 39.6 CFM _ 0.18 ACH 2: Estimated Design Infiltration Rate: Winter. 62.3 CFM 0.28 ACH Summer. 34.5 CFM 0.16 ACH 3. Recommended Minimum Ventilation Guideline: 77.8 CFM (based on ASHRAE 62-89 and 136-93) .60.7 in2 LBL ELA _ Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 Date of Test: 2-20-09 Test File: Treeline 2155 Orchard PI Bld L Building Conditions Inside Temperature: 68 deg F Heating Fuel: Gas \ Outside Temperature: 45 deg F Heating Fuel Cost: # of Stories 3.0 Heating Efficiency: Heating.Degree Days: 6020 Wind Shield: M Cooling Fuel Cost: # of'Occupants Cooling SEER: Cooling Degree Days: 287 # of Bedrooms: 4.0 Volume: 13336 ft3 Ventilation Weather Factor: 0.87 Surface Area: Energy Climate Factor:. 17.0 Floor Area: 1456 ft2 Design Winter Wind Speed: M mph Design Winter Temp Diff: 69 deg F - Design Summer Wind Speed: 7.0 mph Design Summer Temp Diff: 16 deg F Comments BUILDING LEAKAGE TEST Page 3 Date of Test: 2-20-09 Test File: Treeline 2155 Orchard PI Bld L Data Points: Data Entered Manually Nominal Temperature Building Fan Pressure Nominal Adjusted Fan Baseline Pressure (Pa) (Pa) Flow Flow % Error Configuration Std Dev (Pa) -0.8 n/a +/- 0.00 40.1 26.0 906 886 0.5 Ring A . -44.9 31.4 995 973 -0.7 Ring A -50.9 40.6 1130 1105 0.3 Ring A -1.0 n/a +/- 0.00 :