Loading...
HomeMy WebLinkAbout520 Bannock St - Disclosures/Blower Door Test - 04/15/2014t „. G.S �Slerv-pes BUILDING LEAKAGE TEST GS Services 2000 South College Ave #308 Fort Collins, CO 80525 Date of Test: 4-15-14 Test File: Encore Homes 520 Bannock BD Customer: Encore Homes Technician: Paul Higman Project Number: Windsor, CO 80550 Building Address: 520 Bannock Trail Fort Collins, CO 80524 Test Results 1. Airflow at 50 Pascals: 1117 CFM50 (+/- 0.4 %) (50 Pa = 0.2 w.c.) 3.68 ACH50 0.7050 CFM50/ft2 floor area 2. Leakage Areas: 204.6 in2 (+/- 1.2 %) Canadian EgLA @ 10 Pa 151.0in2(+/-2.0%)LBLELA@4Pa 3. Building Leakage Curve: Flow Coefficient (C) = 353.9 ( +/- 3.1 %) Exponent (n) = 0.294 ( +/- 0.008 ) Correlation Coefficient = 0.99711 4. Test Settings: Test Standard: CGSB Test Mode: Depressurization Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 149.6 CFM 0.49 ACH 2. Estimated Design Infiltration Rate: Winter: 254.9 CFM Summer: 143.0 CFM 0.84 ACH 0.47 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 9 Digitally signe( Paul by:,Paul Higm; QN:.CN = Pau Higman,Higiman C= Date. 2014.04, 07:43:59 -06'( d' wyf '"A GSYServices BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 4-15-14 Test File: Encore Homes 520 Bannock BD Building Information Volume 18207 Surface Area Floor Area 1585 Height 16 # of Bedrooms 3 # of Occupants Year of Construction 2014 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6020 Cooling Degree Days 287 Design Winter Wind Speed 9.0 mph Design Summer Wind Speed 7.0 mph Design Winter Temp Diff 69 deg F Design Summer Temp Diff 16 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 GS Services BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 4-15-14 Test File: Encore Homes 520 Bannock BD Depressurization Test: Environmental Data Indoor Temperature (A°F) Outdoor Temperature (A°F) 67.0 61.0 Data Points - Data Entered Manually . Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -1.2 n/a n/a -60.1 -59.0 42.9 1189 1182 0.8 Ring A -55.6 -54.5 40.9 1161 1154 0.7 Ring A -50.3 -49.2 37.5 1113 1107 -0.5 Ring A -45.2 -44.1 34.5 1068 1062 -1.4 Ring A -40.1 -39.0 32.4 1036 1030 -0.8 Ring A -35.0 -33.9 30.2 1001 995 -0.2 Ring A -30.1 -29.0 28.0 966 960 0.9 Ring A -25.5 -24.4 237.4 912 907 0.2 Ring B -20.1 -19.0 205.0 848 843 0.3 Ring B -1.0 n/a n/a Deviations from Standard CGSB - Test Parameters - n value (0.294) outside of acceptable limits. GS Services --= BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 4-15-14 Test File: Encore Homes 520 Bannock BD Comments House WRT Garage =-45.4pa City of Fort Collins ,N�_ . Planning, Development & Transportation Services Community Development & Neighborhood Services Simulated Performance Alternative (SPA) Cover Sheet Submittal and Rating Type Stock Plan Permit — Projected Worst -Case Rating Lot -specific Permit - Projected Rating ❑� Completed Home — Confirmed Rating Data Required for All SPA Ratings Builder: Encore Homes Energy rater: Paul Higman Builder Model Address Address: 520 Bannock Street Rating Firm: GS Services Date: 4-15-14 Duct Location Inputs Location Su ply Return % Area I R-Value % Area R-Value All within conditioned space 100 0 100 0 Utility Rates Energy Source Service charge Rate Electricity 5 $/month 0.10 $/kWh Natural gas 15 $/month 0.60 $/therm Spaces considered outside the thermal boundary: Additional Information for Stock Plan Permit — Projected Worst -Case Rating 'Worst -case" configuration: Foundation type(s) Options included Orientation of front elevation HAttach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report Attach REM/Rate Energy Code Inspection Checklist Additional Information for Lot -Specific Permit — Projected Rating ttach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report ttach REM/Rate Energy Code Inspection Checklist Additional Information for Completed Home — Confirmed Rating ❑� Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report (Utility rates reflected in this report must be City -approved rates on lot -specific permit application date.) Attach Home Energy Rating Certificate Updated 11/09/2012