Loading...
HomeMy WebLinkAbout3063 Denver Dr - Disclosures/Final Energy - 03/28/20142012 IECC ANNUAL ENERGY COST COMPLIANCE Date: March 26, 2014 Rating No.: 05271106 DE Building Name: 3063 Rating Org.: BCCI-Burgess Inc. Owner's Name: Savant Homes Phone No.: 303-300-4527 Property: 3063 Denver Drive Rater's Name: Robert Hutchinson Address: Fort Collins, CO 80525 Rater's No.: 7479033 Builder's Name: Savant Homes Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 3063 Denver Dr.blg Rating Date: 3/25/2014 REM/Rate - Residential Energy Analysis and Rating Software v14.4 This information does not constitute any warranty of energy cost or savings. © 1985-2013 Architectural Energy Corporation, Boulder, Colorado. Annual Energy Cost ($) 2012 IECC As Designed Heating: 296 300 Cooling: 141 76 Water Heating: 390 390 SubTotal - Used to Determine Compliance: 827 767 Lights & Appliances: 732 720 Photovoltaics: -0 -0 Service Charge: 240 240 Total: 1800 1727 * Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.480 0.340 Home Infiltration (Section 402.4.1.2): PASSES Duct Leakage (Section 403.2.2): PASSES Mechanical Ventilation (Section 403.5): PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2012 International Energy Conservation Code based on a climate zone of 5B. In fact, this home surpasses the requirements by 7.3%. Name: Robert Hutchinson Signature: Organization: BCCI-Burgess Inc. Date: March 26, 2014 * Design energy cost is based on the following systems: Heating: Fuel-fired air distribution, 45.0 kBtuh, 95.0 AFUE. Water Heating: Conventional, Elec, 0.91 EF. Cooling: Air conditioner, 11.8 kBtuh, 13.0 SEER. B1305004 2012 IECC ANNUAL ENERGY COST COMPLIANCE 3063 Page 2 REM/Rate - Residential Energy Analysis and Rating Software v14.4 This information does not constitute any warranty of energy cost or savings. © 1985-2013 Architectural Energy Corporation, Boulder, Colorado. Window-to-Floor Area Ratio: 0.11 Blower door test: Htg: 980 Clg: 980 CFM50 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2012 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. B1305004 2012 IECC Certificate 3063 Denver Drive, Fort Collins, CO 80525 Building Envelope Insulation Ceiling Flat: R-38.0 Vaulted Ceiling: NA Above Grade Walls: R-19.0 Foundation Walls: R-11.0 Exposed Floor: NA Slab: R-0.0 Edge, R-0.0 Under Infiltration: Htg: 980 Clg: 980 CFM50 Duct: NA Total Duct Leakage: 128.00 CFM @ 25 Pascals Window Data U-Factor SHGC Window: 0.340 0.310 Mechanical Equipment HEAT: Fuel-fired air distribution, Natural gas, 95.0 AFUE. COOL: N/A DHW: Conventional, Electric, 0.91 EF, 50.0 Gal. Builder or Design Professional Signature __________________________________________ REM/Rate - Residential Energy Analysis and Rating Software v14.4 B1305004 3063 3063 Denver Drive Fort Collins, CO 80525 5 Stars Plus Confirmed Registry ID: 633261792 Rating Number: 05271106 DE Certified Energy Rater: Robert Hutchinson Rating Date: 3/25/2014 Rating Ordered For: Savant Homes Estimated Annual Energy Cost Confirmed Use MMBtu Cost Percent Heating 39.5 $255 16% Cooling 0 $0 0% Hot Water 13.3 $391 24% Lights/Appliances 29.8 $720 45% Photovoltaics -0.0 $-0 -0% Service Charges $240 15% Total 84.6 $1606 100% This home meets or exceeds the minimum criteria for all of the following: EPA ENERGY STAR Version 2 Home 2006 International Energy Conservation Code 2009 International Energy Conservation Code 2012 International Energy Conservation Code Burgess Consultants 101 W Renner Rd Suite 400 Richardson, TX 75082 214-888-7300 214-888-7266 Uniform Energy Rating System 1 Star 1 Star Plus 2 Stars 2 Stars Plus 3 Stars 3 Stars Plus 4 Stars 4 Stars Plus 5 Stars 5 Stars Plus 500-401 400-301 300-251 250-201 200-151 150-101 100-91 90-86 85-71 70 or Less Energy Efficient HERS Index: 67 Efficient Home Comparison: 33% Better General Information Conditioned Area: 2636 sq. ft. HouseType: Single-family detached Conditioned Volume: 27496 cubic ft. Foundation: More than one type Bedrooms: 3 Mechanical Systems Features Heating: Fuel-fired air distribution, Natural gas, 95.0 AFUE. Water Heating: Conventional, Electric, 0.91 EF, 50.0 Gal. Duct Leakage to Outside: 0.00 CFM25. Ventilation System: Exhaust Only: 56 cfm, 11.3 watts. Programmable Thermostat: Heating: Yes Cooling: Yes Building Shell Features Ceiling Flat: R-38.0 Slab: R-0.0 Edge, R-0.0 Under Sealed Attic: NA Exposed Floor: NA Vaulted Ceiling: NA Window Type: U-Value: 0.340, SHGC: 0.310 Above Grade Walls: R-19.0 Infiltration Rate: Htg: 980 Clg: 980 CFM50 Foundation Walls: R-11.0 Method: Blower door test Lights and Appliance Features Percent Interior Lighting: 10.00 Range/Oven Fuel: Natural gas Percent Garage Lighting: 0.00 Clothes Dryer Fuel: Natural gas Refrigerator (kWh/yr): 475.00 Clothes Dryer EF: 2.67 Dishwasher Energy Factor: 0.68 Ceiling Fan (cfm/Watt): 0.00 The Home Energy Rating Standard Disclosure for this home is available from the rating provider. REM/Rate - Residential Energy Analysis and Rating Software v14.4 This information does not constitute any warranty of energy cost or savings. © 1985-2013 Architectural Energy Corporation, Boulder, Colorado. B1305004