Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
938 Ridge Runner Dr - Disclosures/Final Energy - 10/08/2013
i31JnG�OJ C 2015 Runner 938 Ridge Runner Drive Fort Collins, CO 80524 COMMON; CONSULTANTS' INC., 5 Stars Plus Confirmed Uniform Energy Rating System Energy Efficient 1 Star 1 Star Plus 1 2 Stars 1 2 Stars Plus 1 3 Stars 3 Stars Plus 4 Stars 4 Stars Plus 5 Stars 5 Stars Plus 500-401 400-301 300-251 250-201 200-151 150-101 100-91 90-86 85-71 70 or Less HERS Index: Duct Leakage to Outside: Ventilation System: Programmable Thermostat: Ceiling Flat: Sealed Attic: Vaulted Ceiling: Above Grade Walls: Foundation Walls: Efficient Home Comparison: 34% Better 0.00 CFM25. Exhaust Only: 68 cfm, 11.3 watts. Heating: Yes Cooling: Yes R-38 Slab: NA Exposed Floor: R-38 Window Type: R-15, R-19 Infiltration Rate: R-19.0 Method: R-0.0 Edge, R-0.0 Under R-30 Double - Vinyl 3430"' Htg: 1205 Clg: 1205 CFM50 Blower door test Percent Interior Lighting: 10.00 Range/Oven Fuel: Natural gas Percent Garage Lighting: 0.00 Clothes Dryer Fuel: Electric Refrigerator (kWh/yr): 775.00 Clothes Dryer EF: 2.67 Dishwasher Energy Factor: 0.68 Ceiling Fan (cfm/Watt): 0.00 The Home Energy Rating Standard Disclosure for this home is available from the rating provider. REM/Rate - Residential Energy Analysis and Rating Software v14.3 This information does not constitute any warranty of energy cost or savings. m 1985-2013 Architectural Energy Corporation, Boulder, Colorado. Registry ID: Rating Number: Certified Energy Rater: Rating Date: Rating Ordered For: 849914121 Worst Case Scenario YK Robert Hutchinson 10/812013 DR Horton Estimated Annual Energy Cost Confirmed Use MMBtu Cost Percent Heating 51.9 $361 23% Cooling 0 $0 0% Hot Water 22.0 $143 1 9% Lights/Appliances 34.6 $846 54% Photovoltaics -0.0 $-0 -0% Service Charges $204 113% Total 111.2 $1554 1000% This home meets or exceeds the minimum criteria for ail of the following: EPA ENERGY STAR Version 2 Home 2006 International Energy Conservation Code 2009 International Energy Conservation Code �Monr"anoit Burgess ConstructionConsultants 101 West Renner Road, Suite 400 Richardson, Texas 75082 214-888-7260 214-888-726 7479033 / Certified Energy Rater BURGESS _twl . FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT Date: October 09, 2013 Rating No.: Worst Case Scenario YK Building Name: 2015 Rating Org.: Burgess Inc. Owners Name: DR Horton Phone No.: 303-300-4527 Property: 938 Ridge Runner Drive Raters Name: Robert Hutchinson Address: Fort Collins, CO 80524 Raters No.: 7479033 Builders Name: DR Horton Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 938 Ridge Runner Drive.blg Rating Date: 10/8/2013 Annual Energy Cost ($) FC 2012 As Designed Heating: 450 426 Cooling: 141 85 Water Heating: 142 142 SubTotal - Used to Determine Compliance: 734 653 Lights & Appliances: 861 846 Photovoltaics: -0 -0 Service Charge: 204 204 Total: 1799 1703 ' Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.400 0.340 Home Infiltration (Section 402.4.2): Duct Leakage (Section 403.2.2): PASSES PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the rements by 11.0%. Name: Robert Hutchinson Signature: 7479033 Organization: Burgess Inc. Date: October 09, 2013 ' Design energy cost is based on the following systems: Heating: Fuel -fired air distribution, 80.0 kBtuh, 92.0 AFUE. Water Heating: Conventional, Gas, 0.60 EF. Cooling: Air conditioner, 17.4 kBtuh, 13.0 SEER. Window -to -Floor Area Ratio: 0.13 REWRate - Residential Energy Analysis and Rating Software v14.3 This information does not constitute any warranty of energy cost or savings. 01985-2013 Architectural Energy Corporation, Boulder, Colorado. FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT 2015 Page 2 Blower door test: Htg: 1205 Clg: 1205 CFM50 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate - Residential Energy Analysis and Rating Software v14.3 This information does not constitute any warranty of energy cost or savings. ©1985-2013 Architectural Energy Corporation, Boulder, Colorado. Fort Collins Energy Cost Compliance BURGESS - Non Electric Heat B Property Organization HERS DR Horton Burgess Inc. Projected Rating CONSTRUCTION 938 Ridge Runner Drive 303-300-4527 4/12/2013 CONSULTANTS Fort Collins, CO 80524 Robert Hutchinson Rating No:Worst Case INC. Scenario SINCE 1986 Weathefft. Collins, CO Builder Rater ID:7470933 2015 DR Horton 938 Ridge Runner Drive.blg Annual Energy Cost $iyr FC 2012 As Designed Heating 455 446 Cooling ' 110 85 Water Heating 142 142 ((SubTotal - Used to Determine Compliance u 708 "67 Lights E2 Appliances 880 865 Photovoltaics -0 .0 Service Charge 204 204 Total - - -, �.. — '1792 -1742 Mandatory Requirements Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower) 0.400 0.340 Home Infiltration (Section 402.4.2) PASSES Duct Leakage (Section 403.2.2) PASSES This home MEETS the annual energy cost requirements of Section 405 of the amended by the City of Fort Collins. In fact, this home surpasses the require Name Robert Hutchinson Organization Burgess Inc. Mechanical Systems Heating Cooling Water Heating Window -to -Floor Area Ratio: Blower door test Signature Date 4 Fuel -fired air distribution, 80.0 kBtuh, 92.0 AFUE. Air conditioner, 42.0 kBtuh, 13.0 SEER. Conventional, Gas, 0.60 EF. 0.13 Htg: 1205 Clg: 1205 CFM50 Energy Conservation Code, �)OQc�, % col=F In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate - Residential Energy Analysis and Rating Software v14.3 This information does not constitute any warranty of energy cost or savings. 0 1985-2013 Architectural Energy Corporation, Boulder, Colorado.