Loading...
HomeMy WebLinkAbout3664 Galileo Dr - Disclosures/Blower Door Test - 11/26/2013BUILDING LEAKAGE TEST Date of Test: 11/26/2013 Customer: Village Homes Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: Test File: Untitled Technician: Project Number: Building Address: 3664 Galileo Dr 1033 CFM50 (+/- 0.6 %) 1.70 ACH50 56.8 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 363.8 ( +/- 14.7 %) Exponent (n) = 0.267 ( +/- 0.036 ) Correlation Coefficient = 0.98854 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 47.4 CFM 0.08 ACH 9.5 CFM per person Winter: 69.2 CFM Summer: 50.8 CFM 0.11 ACH 0.08 ACH BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 11/26/2013 Test File: Untitled Building Information Location Climate Information Volume 36491 Surface Area 8681 Floor Area 3556 Height 9 # of Bedrooms 4 # of Occupants 5 Year of Construction Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 11/26/2013 Test File: Untitled Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 70.0 48.0 1 5280.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -1.5 n/a n/a -66.0 -64.8 40.3 -64.0 -62.8 40.0 -62.0 -60.8 38.7 -60.0 -58.8 39.0 -58.0 -56.8 38.0 -56.0 -54.8 36.7 -54.0 -52.8 36.1 -52.0 -50.8 35.3 -50.0 -48.8 34.8 -0.9 ' n/a n/a Time Averaging Period: 10 1153 1105 -0.2 Ring A 1148 1100 0.2 Ring A 1130 1083 -0.5 Ring A 1134 1087 0.7 Ring A 1120 1073 0.4 Ring A 1101 1055 -0.4 Ring A 1092 1046 -0.2 Ring A 1081 1036 -0.2 Ring A 1073 1028 0.2 Ring A Deviations from Standard RESNET Multi -Point Test - Test Parameters None. - * n value outside of normally accepted limits. - * correlation coefficient outside of normally accepted limits. * n value and/or correlation coefficient limits are not officially part of the RESNET Multi -Point Test Standard.. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 11/26/2013 Test File: Untitled Comments None Tested garage connection to home at 49 pascals at . Passes Ft Collins requirement of 45 or higher The connection to the CAZ was NA because all appliances are sealed combustion.