HomeMy WebLinkAbout3658 Galileo Dr - Disclosures/Blower Door Test - 12/12/2013BUILDING LEAKAGE TEST Date of Test: 12/12/13 Test File: 3658 Galileo Dr -Village-Multi Point Tectite Customer: Village Homes Technician: Justin Heldenbrand Project Number: EnergyLogic (30063) Building Address: 3658 Galileo Dr Fort Collins, CO 80528 Test Results 1. Airflow at 50 Pascals: 1047 CFM50 (+/- 1.1 %) (50 Pa = 0.2 w.c.) 1.91 ACH50 2. Leakage Area: 57.6 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 54.9 (+/- 8.4 %) Exponent (n) = 0.754 ( +/- 0.023 ) Correlation Coefficient = 0.99953 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 61.0 CFM 0.11 ACH 8.7 CFM per person Winter: 114.8 CFM Summer: 72.0 CFM 0.21 ACH 0.13ACH Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: 88.0 CFM Base Rate: 88.0 CFM Infiltration Credit: <0.0 CFM> BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 12/12/13 Test File: 3658 Galileo Dr -Village-Multi Point Tectite Building Information Location Climate Information Volume 32852 Surface Area 7054 Floor Area 3549 Height 20 # of Bedrooms 6 # of Occupants 7 Year of Construction Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory I Model 3 (110V) I Default BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 12/12/13 Test File: 3658 Galileo Dr -Village-Multi Point Tectite Depressurization Test: Environmental Data Indoor Temperature (OF) Outdoor Temperature (OF) Altitude (ft) 70.0 42.0 5000.0 Data Points Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -4.8 n/a n/a -63.7 -60.1 44.9 -58.0 -54.4 38.8 -52.6 -48.9 34.1 -47.5 -43.8 27.0 -40.1 -36.5 200.0 -34.6 -30.9 153.3 -28.9 -25.3 114.6 -23.4 -19.7 78.6 -2.5 n/a n/a Time Averaging Period: 0 None 1214 1197 -0.4 Ring A 1131 1115 0.0 Ring A 1063 1048 1.8 Ring A 948 935 -1.3 Ring A 838 826 0.1 Ring B 734 724 -0.6 Ring B 636 627 0.2 Ring B 527 520 0.2 Ring B Deviations from Standard RESNET Multi -Point Test - Test Parameters BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 12/12/13 Test File: 3658 Galileo Dr -Village-Multi Point Tectite Comments Connections to: Garage -48.2 Pa Mechanical -50 Pa.