Loading...
HomeMy WebLinkAbout920 Campfire Dr - Disclosures/Blower Door Test - 01/15/2014BUILDING LEAKAGE TEST Date of Test: 01/15/2014 Technician: Doug Groff Test File: DR Horton Blower door Customer: DR Horton Building Address: 920 Campfire Drive 7600 E Orchard Rd #350-S Fort Collins, Colorado 80524 Greenwood Village, Colorado 80111 Phone Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Minneapolis Leakage Ratio: 4. Building Leakage Curve: 5. Test Settings: 1112CFM (+/-0.3%) 3.45 ACH 0.50 CFM per ft2 floor area 267.5 in2 (+/- 3.3 %) Canadian EgLA @ 10 Pa 230.2 in2 (+/- 5.0 %) LBL ELA @ 4 Pa 0.27 CFM50 per ft2 surface area Flow Coefficient (C) = 683.1 (+/- 7.7 %) Exponent (n) = 0.125 ( +/- 0.019 ) Correlation Coefficient = 0.96549 Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 247.4 CFM 0.77 ACH 2. Estimated Design Infiltration Rate: Winter: 389.0 CFM 1.21 ACH Summer: 221.1 CFM 0.69 ACH 3. Recommended Whole Building Mechanical 0.0 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 Date of Test: 01/15/2014 Test File: DR Horton Blower door Building Conditions Inside Temperature: 68 deg F Heating Fuel: Gas Outside Temperature: 46 deg F Heating Fuel Cost: # of Stories 2.0 Heating Efficiency: Heating Degree Days: 6020 Wind Shield: M Cooling Fuel Cost: # of Occupants Cooling SEER: Cooling Degree Days: 287 # of Bedrooms: 3.0 Volume: 19354 ft3 Ventilation Weather Factor: 0.87 Surface Area: 4140 ft2 Energy Climate Factor: 17.0 Floor Area: 2232 ft2 Design Winter Wind Speed: 9.0 mph Design Winter Temp Diff: 69 deg F Design Summer Wind Speed: 7.0 mph Design Summer Temp Diff: 16 deg F Comments GARAGE WRT HOUSE: 46.5 Pa @ 50 Pa BUILDING LEAKAGE TEST Page 3 Date of Test: 01/15/2014 Test File: DR Horton Blower door Data Points: Data Entered Manually Nominal Temperature Building Fan Pressure Nominal Adjusted Fan Baseline Pressure (Pa) (Pa) Flow Flow % Error Configuration Std Dev (Pa) -1.1 n/a -65.0 41.9 1175 1150 0.3 Ring A -60.0 40.8 1160 1136 0.0 Ring A -55.0 39.7 1145 1121 -0.2 Ring A -50.0 38.3 1125 1101 -0.7 Ring A -45.0 38.3 1125 1101 0.6 Ring A +/- 0.00