Loading...
HomeMy WebLinkAbout920 Campfire Dr - Disclosures/Final Energy - 01/15/2014BURGESS Q 5aelff GL [t2G� 6(c'*A�. DR Horton 1220 � V 920 Campfire Drive Fort Collins, CO 80524 NiINC.\ 'IS w COwww� C UCIA'I'S IBC 5 Stars Plus Confirmed Uniform Energy Rating System Energy Efficient 1 Star 1 1 Star Plus 2 Stars 2 Stars Plus 3 Stars 3 Stars Plus 4 Stars 4 Slars Plus 5 Stars 5 Stars Plus 500 401 400-301 300-251 250-201 200-151 150-101 1100-91 90-86 I 85-71 1 70 or Less HERS Index: 66 Efficient Home Comparison: 34% Better Conditioned Area: 2232 sq. ft. HouseType: Single-family detached Conditioned Volume: 19354 cubic ft. Foundation: Conditioned basement Bedrooms: 3 Heating: Fuel -fired air distribution, Natural gas, 92.0 AFUE. Water Heating: Conventional, Natural gas, 0.65 EF, 40.0 Gal. Duct Leakage to Outside: 0.00 CFM25. Ventilation System: Exhaust Only: 52 cfm, 11.3 watts. Programmable Thermostat: Heating: Yes Cooling: Yes Building ShellFeatures -, Ceiling Flat: R-38 Slab: R-0.0 Edge, R-0.0 Under Sealed Attic: NA Exposed Floor: R-30 Vaulted Ceiling: NA Window Type: D/LoE - Vinyl 3430******* Above Grade Walls: R-15 Infiltration Rate: Htg: 1125 Clg: 1125 CFM50 Foundation Walls: R-19.0 Method: Blower door test i Lghts and Appliance Features] Percent Interior Lighting: 80.00 Range/Oven Fuel: Natural gas Percent Garage Lighting: 0.00 Clothes Dryer Fuel: Electric Refrigerator (kWh/yr): 775.00 Clothes Dryer EF: 2.67 Dishwasher Energy Factor: 0.46 Ceiling Fan (cfm/Watt): 0.00 The Home Energy Rating Standard Disclosure for this home is available from the rating provider. REM/Rate - Residential Energy Analysis and Rating Software v14.3 This information does not constitute any warranty of energy cost or savings. © 1985-2013 Architectural Energy Corporation, Boulder, Colorado. Registry ID: Rating Number: Certified Energy Rater: Rating Date: Rating Ordered For: 361572173 Worst Case Scenario Robert Hutchinson 1/15/14 DR Horton 9 �G Estimated Annual Energy Cost Confirmed Use MMBtu Cost Percent Heating 43.3 $300 24% Cooling 0 $0 0% Hot Water 18.9 $123 10% Lights/Appliances 25.0 $599 49% Photovoltaics -0.0 $-0 -0% Service Charges $204 17% Total 89.1 $1226 100% This home meets or exceeds the minimum criteria for all of the following: EPA ENERGY STAR Version 2 Home 2006 International Energy Conservation Code 2009 International Energy Conservation Code 3 �,,oatc�ce Burgess ConstructionConsultants Ao+' 101 West Renner Road, Suite 400 Richardson, Texas 75082 214-888-7260 = rNo 1998.144i1e'. 214-888-7261 _ 7479033 Certified Energy Rater 4o,sm�cT�a. FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT Date: January 16, 2014 Rating No.: Worst Case Scenario Building Name: DR Horton 1220 Rating Org.: Burgess, Inc Owner's Name: DR Horton Phone No.: 214-291-3141 Property: 920 Campfire Drive Rater's Name: Robert Hutchinson Address: Fort Collins, CO 80524 Rater's No.: 7479033 Builders Name: DR Horton Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 920 Campfire Dr.blg Rating Date: 1/15/14 Annual Energy Cost ($) FC 2012 As Designed Heating: 358 352 Cooling: 100 62 Water Heating: 122 122 SubTotal - Used to Determine Compliance: 580 536 Lights & Appliances: 609 599 Photovoltaics: -0 -0 Service Charge: 204 204 Total: 1393 1339 ' Mandatory Requirements: Duct Insulation R-Value Check (per Section 405.2) Minimum Duct Insulation (Design must be equal or higher): 6.0 8.0 Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.400 0.340 Home Infiltration (Section 402.4.2): PASSES Duct Leakage (Section 403.2.2): PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the P uireuire;�ments by 7.6%. Name: Robert Hutchinson Signature: ; . 7479033 Organization: Burgess, Inc Date: 'January 2014 REM/Rate - Residential Energy Analysis and Rating Software v14.3 This information does not constitute any warranty of energy cost or savings. 0 1985-2013 Architectural Energy Corporation, Boulder, Colorado. FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT DR Horton 1220 Page 2 ` Design energy cost is based on the following systems: Heating: Fuel -fired air distribution, 60.0 kBtuh, 92.0 AFUE. Water Heating: Conventional, Gas, 0.65 EF. Cooling: Air conditioner, 12.0 kBtuh, 13.0 SEER. Window -to -Floor Area Ratio: 0.12 Blower door test: Htg: 1125 Clg: 1125 CFM50 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate - Residential Energy Analysis and Rating Software v14.3 This information does not constitute any warranty of energy cost or savings. ©1985-2013 Architectural Energy Corporation, Boulder, Colorado.