HomeMy WebLinkAbout2856 Exmoor Ln - Special Inspections/Engineering - 11/05/2013RMG ENGINEERS 11-�_ Job No. 140626 November 5, 2013 Journey Homes, Northern CO 7251 W. 20th St., L-200 Greeley, CO 80634 Re: Footing and Foundation Observation 2856 Exmoor Ln Lot 152, Rigden Farms, Filing No. 6, Final Plat Fort Collins, Colorado Dear Larry: lWrk farox RrcAKwr.> &: wrsea As requested, personnel of RMG Engineers Group (RMG) observed the footing and foundation formwork and reinforcing steel for the above referenced single family residential property and found them to be in substantial compliance with the design drawings prepared by High Plains Engineering & Design, LLC for this structure. The "Ufer" electrical ground system was placed in the footing and meet the requirements of Article 250.52(A)(3) of the 2008 National Electrical Code (NEC). The footings were observed on November 4, 2013 and the foundation walls were observed on November 5, 2013. Should you have questions, please feel free to contact our office. Cordially, REG, 11/6/13 2499J 5 Thomas M. Cope S/014AL E Professional Engineer Structural ; Geotechnical RMG www.ringengineers.com Job No. 140626 November 7, 2013 Journey Homes, Northern CO 7251 W. 20th St., L-200 Greeley, CO 80634 Re: Foundation Damp Proofing 2856 Exmoor Ln Lot 152, Rigden Farms, Filing No. 6, Final Plat Fort Collins, Colorado Dear Larry: Rpbuit to hle�i Rs fe1T •Fecnr.y.9 mra� As requested, personnel of RMG Engineers Group (RMG) observed the foundation damp proofing and found it to be complete and in substantial compliance with the design drawings prepared by High Plains Engineering & Design, LLC for this structure at the date of the inspection. The damp proof was observed on November 7, 2013. Should you have questions, please feel free to contact our office. Cordially, �p REG7sT 40-- ' 11/18/13;Cbt 24995 ............ Thomas M. Cope ss�ONAI ti�7 Professional Engineer Southern Office: Central Office: Northern Office: Colorado Springs, CO Englewood, CO 80112 Evans, CO 80620 719.548.0600 303.688.9475 970.330.1071 Monument: 719.488.2145 Pueblo: 719.544.7750 Woodland Park: 719.687.6077 ructurel • Geotechnical U i$.flt}r !NQ MG'INEERS Job No. 140626 November 7, 20,13 Journey Homes, Northern CO 7251 W. 20th St., L-200 Greeley, CO 80634 Re: Foundation Subsurface Drain Observation 2856 Exmoor Ln Lot 152, Rigden Farms, Filing No. 6, Final Plat Fort Collins, Colorado Dear Larry: As requested, personnel of RMG Engineers Group (RMG) observed the foundation subsurface drainage pipe and sump pit perimeter drain system on November 7, 2013. RMG found it to be complete and in substantial compliance with the design drawings prepared by High Plains Engineering & Design, LLC for this structure at the date of this observation. Should you have questions, please feel free to contact our office. Cordially, 1 1/1 8/13 24995 Thomas M. Cope S�ONAI E Professional Engineer Southern Office: Central Office: Northern Office: Colorado Springs, CO Englewood, CO 80112 Evans, CO 80620 719.548.0600 303.688.9475 970.330.1071 Monument: 719.488.2145 Pueblo: 719.544.7750 Woodland Park: 719.687.6077 RMG ENGINEERS Job No. 140626 November 1, 2013 Journey Homes, Northern CO 7251 W. 20th St., L-200 Greeley, CO 80634 Re: Open Excavation Observation 2856 Exmoor Ln Lot 152, Rigden Farms, Filing No. 6, Final Plat Fort Collins, Colorado Dear Larry: t'orrurucnaty b�u[kloinY fur Fz.:wrirMa;wrncs� RMG Engineers Group (RMG) conducted a foundation excavation review for a single-family residence under construction at the above -referenced site located in Fort Collins, Colorado on November 1, 2013. The footings were excavated to the cobbley clayey sand, which is similar to those soils described in the Subsurface Soil Investigation, Rigden Farms — Sixth Filing — Final Geotech, Fort Collins, Colorado, prepared by RMG Engineers Group, RMG Job No. 139917 and dated October 2, 2013. RMG did not encounter groundwater within three feet of the proposed footing elevation. The soils supporting the footings will be a low expansive material. Based on the soil conditions encountered within three feet of the footing level, a continuous spread footing may be designed and constructed in accordance to the above mentioned Subsurface Soil Investigation. Should you have questions, please feel free to contact our office. Cordially, .24995 Thomas M. Cope Professional Engineer IM