HomeMy WebLinkAbout5814 Big Canyon Dr - Disclosures/Blower Door Test - 12/03/2013BUILDING LEAKAGE TEST t3130c9P4(P3 Date of Test: 12/3/2013 Test File: Ryland McClelland Creek 5203 Customer: Ryland Technician: Paul Gelatt Project Number: 29943 Energy Logic Building Address: 5814 Big Canyon Dr Ft Collins, CO 80522 Test Results 1. Airflow at 50 Pascals: 1536 CFM50 (+/- 0.8 %) (50 Pa = 0.2 w.c.) 2.14 ACH50 2. Leakage Area: 84.5 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 103.9 (+/- 21.0 %) Exponent (n) = 0.688 ( +/- 0.053 ) Correlation Coefficient = 0.99708 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 88.2 CFM 0.12ACH 14.7 CFM per person Winter: 139.9 CFM Summer: 92.8 CFM 0.19 ACH 0.13 ACH Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: 91.3 CFM Base Rate: 91.3 CFM Infiltration Credit: <0.0 CFM> BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 12/3/2013 Test File: Ryland McClelland Creek 5203 Building Information Location Climate Information Volume 43132 Surface Area 8681 Floor Area 4630 Height 19 # of Bedrooms 5 # of Occupants 6 Year of Construction 2013 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 12/3/2013 Test File: Ryland McClelland Creek 5203 Depressurization Test: Environmental Data Indoor Temperature (OF) Outdoor Temperature (OF) Altitude (ft) 66.0 35.0 5500.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Building Pressure Building Pressure Pressure (Pa) (Pa) (Pa) Nominal Adjusted Flow Flow Fan (cfm) (cfm) % Error Configuration 0.0 n/a n/a 44.0 -44.0 63.6 1440 1406 -0.0 Ring A 47.0 -47.0 71.1 1520 1484 0.8 Ring A -50.0 -50.0 74.0 1550 1513 -1.5 Ring A -53.0 -53.0 84.1 1650 1611 0.8 Ring A -56.0 -56.0 89.4 1700 1660 -0.0 Ring A -59.0 -59.0 96.0 1760 1718 -0.2 Ring A -62.0 -62.0 102.8 1820 1777 -0.2 Ring A -65.0 -65.0 111.1 1890 1845 0.3 Ring A 0.0 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi -Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 12/3/2013 Test File: Ryland McClelland Creek 5203 Comments connection to garage; 47 pa, pass. Mech. systems isolated,sealed combustion.