HomeMy WebLinkAbout3013 Bowie Ave - Special Inspections/Engineering - 08/30/2013DL Engineering Inc. 7`=.3 Structural /'Civil Engineering 2996 S. Lamar Street Denver, CO 80227 720+413.8982 dlemier@dlengineer.com w"Alangineer.com 8/30/2013 . Complete Basement.Systems 3256 Quentin Street, #104 Aurora, CO 80011 RE: Job Number 2013-100 Site Observation Visit (Armstrong) 3013 Bowie Ave. Fort Collins, CO 80526 DL Engineering Inc. reviewed the progress of construction for the subject project on August 27st, 2013. The following is a summary of the observations made:. New Observations: • Reviewed the push piers and log. The push piers appeared to be installed in conformance with the. structural mitigation plan. • Site grading around the perimeter of the house did not appear to be modified. Vegetation around the perimeter of the house did not appear to be modified. Volatile Soils: The moisture around the foundation elements must be controlled for the useful life of the building. Time has shown that Colorado soils can be unstable and structures can, experience damaging movements due to expanding and shrinking soils, primarily when moisture changes occur. Maintaining consistent soil moisture contents around all foundation elements is crucial to minimizing foundation movements. Even with properly engineered/constructed foundation systems these volatile soils can still exert excessive pressures causing damage in the residence. If the Owner would like further insight about the on-site.soil conditions and preventative measures, a Geotechnical Engineer should be consulted. Geotechnical Consideration: it is possible that the wall anchors may consolidate the soil behind the foundation wall. Because of this, periodic surveys of the supported structures should be conducted to assure project success. The Owner should be responsible for annual surveys certifying project success. It is recommended that a baseline survey be conducted immediately. The Owner should report all findings and reports to the Structural Engineer. If horizontal movement of the foundation walls or wall anchors is discovered, the anchors should be re -tensioned. A Geotechnical Engineer should be present for the re-torqueing of the wall anchors. Disclaimer: in as much as the site review of an existing structure.for the purpose of observing the structure conditions requires that certain assumptions be made regarding existing conditions and because some of these assumptions may not be verifiable without expending additional sums of money or destroying otherwise adequate orserviceabie portions of the building, the Client agrees that, except for negligence � � '�'�i�' DL Engineering inc: 'iatiYi' . . . , �`'�`_s Strucfurat/Civil Engineering on the part of the Engineer,the.Client wili hold harmless,indemnify and tlefend Engineer from and against any and all claims arising out.of the professional services we have provided. If you should have any further questions,please feel free to contact me at(720)A13-8982 or dlemier@ dle ngineer.co m. �,,r� ,., PO� R���s , . , 04 �w..1F,pf � U�,..��4, .�9.�Po '�._ :Q 35393 .•� : . �•• ••f���J ' .. / ' , ••�IJ,Y!'���lv '•: ���.7 '�:.7��"" '� Sincerely, Daniel LeMier,,PE P�incipal J Q ' 2 _ , ._... . --. ' ^ , �3��3$� � Co�l�+� ��s�m+��� . � : Q�� ���r�� ` ` °ih��y Boseman!Pe. Date—�`� To Whom It May Concern, ' Enclosed,you will fmd informati�nyou will need t close out Permit number �j ) �[7 U 3@� at..3�l a� .�. " �P � 1--e. ��' Ca����s.,Colorado. For . Please let me lmow if you have any questions. ' Thank You, • Enola Koerselman Gomplete.Basement Systems 3250 Quentin St Suite 104 Aurora, Colo 80011 303-805-8751 c , ... .. . .. . , . ... "+., , ,'�� .-�� ;`:—<��•`•,, .. '' f � f �` '+ ��..• � � � � �, �'�� ���;� t � F � . \ ' k��� sy�µ.':yf�� ' , . . ��n ./t: j . ��.. � i A ' 1 • � • . � CIf 1 : 1 : 1 : � 1 : � e - ^ � .