Loading...
HomeMy WebLinkAbout2532 Sunbury Ln - Special Inspections/Engineering - 10/30/2013Weyerhaeuser October 30, 2013 Dean Pace Journey Homes 7251 West 20th Street Bldg. L Suite 200 Greeley, CO 80634 2s 3� J81303C,61 l Subject: 7251 WEST 20TH ST., BUILDING L, SUITE 200 s0 o 4�1t)l I -Pt At your request, I have reviewed the TJI® joist used in the referenced construction. You have provided the following information for the above referenced project: The 11 7/8" TJI® 110 Joist at 16" on center has an out to out span of 13'3'/z" and supports floor loading of 40PSF live load and 10PSF dead load. This joist has a 4" long by 6" deep section removed from the top centered at 97' along it's length. With consideration of the damage, the TJI®joist'is STRUCTURALLY INADEQUATE as is. To remedy the situation, the joist should be headered on both sides of the cut to the adjacent single joists by using a TJI header as shown on the enclosed detail 1-12A. The spacing between headers should not exceed 121, O.C. Please note that I have not reviewed the project plans to determine if the product application, design loads, or dimensions are correct. It is important the responsible individual(s) confirm this information. If you have any further questions, please contact me at the number below. Sincerely, Georgia Harmon Structural Frame E.I.T. cc: Brad Keefe INGINEER[ WOOD PRODUCTS Technical Support 9115 E. 90`" Avenue+ Henderson, CO 80640 - Phone 303.770.6262 - Fax 303.770.6324 Face Mount Hangers — (see chart below for sizes) 4" max lio in header BACKER BLOCK (both sides) • Install tight to bottom flange. • Attach with ten 10d (3") box nails, clinched when possible. • If necessary, increase filler and bdcker block height for face mount hangers and maintain 1/8" gap at top of joist • Filler and backer block dimensions should accommodate required nailing without splitting. Header Damaged part of joist to be removed n Backer block both sides of web with single TJI® joists pi HANGER BACKER BLOCK SIZES TJIO 110 joists; 1/8" or 3/4" , minimum length 12" ® TJI® 210 joists; 114" or '/8", minimum length 12" TJI® 230 joists: I" net, minimum length 12" TJI® 360 joists: I" net, minimum length 12" TJI® 560 joists: 2x_, minimum length 12" Weyerhaeuser. USP Structural ConnectorsT1 Simpson Strong -Tie n" Depth I TJI6 ( Hanger Depth I TJI® I Hanger 91/2 { 110. I THF17925 91/2 I 110 I IUS1.81/9.5 I 210 I THF20925 I 210 I IUS2.06/9.5 110 I THF17112 I 110 11US1.81/11.88 I 210 I THF20112 I 210 { IUS2.06/11.88 117/8" I 230 I THF23118 117/8" I 230 11US2.37/11.88 I 360 1 THF23118 I 360 11US2.37/11.88 I 560 I. THE 17112-2 I 560 I I U S 3.56/ 11.88 I 110 I THF17140 I 110 1 IUS1.81/14 I 210 I THF20140 I 210 I IUS2.06/14 14" 1 230 I THF23140 14" ( 230 I IUS2.37/14 I 360 I THF23140 I 360 ( IUS2.37/14 I 560 I THF17140-2 ► 560 I IUS3.56/14 f 210 I THF20157 { 210 I IUS2.06/16 { 230 I THF23160 I 230 I IUS2.37/16 16" 360 I THF23160 161. I 360 I IUS2.37/16 I 560 17HF17157--2 I 560 ( IUS3.56/16 BOLD ITALIC hangers require web stiffeners.