HomeMy WebLinkAbout950 Ridge Runner Dr - Disclosures/Mechanical - 10/31/2013N30431111tt City'bf Fort Collins Residential Mechanical Systems Performance Report This torn is a record of testing targets and results. with Pass/Fail outcomes. For information on measurement tools and testing techniques, see the "Residential New Construction Mechanical Systems Testing Guide." The guideaidthis term may be periodically updated; check the Building Services web site for the current version. This form must be completed and signed by an "Approved Agency," and submitted to Building Services as a requirement for receiving a C.O. Color key 19 '£ Ir, 7�1 D, ;; Measured value to .... ' T Tergettx/hmdu„ compatowthtarget or Pass Fella Caullon OOterdafa limit - , � 2 t:ocal Vent ',Exhaust (Spot) �.k c..w^�. a.: -*....»,. •.�:ea.r,:x,ac-.�.4 :..v ` '.. ....,r': ''d.`=, Bath exhaust )(Flow box Flow collar Es.. Airflow, measurement method _ Passive flow hood A Pilot tube traverse ft f Temperature of air through /� F Indicated low to Vol umetric flow multiple 11 nnA measurement tool (y (4? 5000', air temperature f " t/ MeasuredExhaust Airflow Oprratlon Minimum Design Indicated Exhaust Pickup Location intermittent or Airflow Airflow FlowCFM Volumetric Flow Pass Fail Continuous Requirement (CFM (CFM) (CFM 5,000') (CFM 5000') 5000') 4 <ntermil _ Conlin n14 'Intermit Conlin r.s, `" " r' r `J ❑ cr _ J! T , 1� t� .„ ; XIntermit Contin �Conlin 7 * a�`❑F ';' Xlntcrmit L✓','ti::,., :Y G,�. ✓�Q � ❑ �r _Intermit _Conlin El _Intermit Conlin ,�'7 ❑ soi�1.,' _ IRlantlil _ Conlin '�° y�.r; ❑ i x ❑ rq.,c _Inturmit Conlin ❑ ,[],;; Kitchen exhaust Oven fuel —Gas Electric Exhaust airflow ,fit NIA- Kitchen hood does not Vent outside A DpOration _ Intertniltenl _ Continuous Minimum exhaust airflow requirement ­r `1 CFM 500ty x; Measured airflow ` Airflow measurement method _ Flow box v Flow Collar -;.iir flow hood Rai tube traverse Y( _Passive Temperature of air through Indicated flow to Voiumetnc flow multiplier measurement tool F @ 5000'. air tomperatura� Indicated Dow CFM Volumetric low ICFM 5009 0 Pass rnl'I Er, Testing notes (fan speed, masking, flow out ofrange....) MmhaNcal Syslems Penomance Tearing Suemiital Form V20120606 + of 6 Systems other than sub -structural floor exhaust =' Minimum exhaust airflow requi!ement "" +' ; CFM 5000, Indicated to Measured Alifiow - Volumatrlc Volumetric It Dasign Alrflow Measurement Measurement Location Flow Indicated Flow (CFM 5000') Method Air Temperature (F) Multiplier (CFM) ) Flow Pass/Fall (CFM 5000') Flow box pDwt(Gv i Total exhaust airflow _ Flow Passive flow tieerl Flow I cWS f q / ^^� 6 M collar _ Pilot tuba traverse • v / f Flo wcollar . Total supply airflow Pilot tube traverse •,- _Flow box Passive flow hood systems in which supply airflow is circulated by the air handler fan, fan speed for measurement Heat Cooling Continuous fan L Balanced airflow In balanced systems. Average of measured suppi Targetflow range z y � lrrr ��. ` and exhauslflows CFM 5000' , , tom CFM.5000' (average -1- 151e) `. Puss w�, j' .;.a fail 'Sub -structural floor exhaust NIA •- no sub -structural floor exhaust syatam .,,.t Design airflow �_,- CFM 5000' Measured airflow 1 Flow box _ Flow collar Airflow measurement nrelhod _ Passive flaw hood Pilot tube traverse x.� )x ,1 i. Temperature of air through F Indicated flow to Volumetric flow multiplier S .A, A„Xr measurement tool Q 5000', air temperature Indicated nowCFM Volumetric flow CFM 5000' Pass ®_!fail 4rK1 Indicated flow to Volumetric flow multiplier House conditioned floor area �sf 5000', air temperature Maximum Allowed Duct Leakage I Measured Duet Leakage Test Parameter and Conditions Normalized Leakage Absolute Indicated Flow Volumetric (CFM251100 of) Leakage (CFM25) (CFM25) Flow (CFM25 6000') Measurement Timing Air Handler PasslFail Total leakage Rough -in Excluded 4 ;•;n: r Total leakage Rough -in Included 6 Total leakage Complete Included 12 Or{ Leakage to outdoors Complete Included 8 Mochan!ml Syffomn Pcnomranne To.aba Subrnr[W Form V2012008 2 are Filter type i Brand Type l s a Thickness . Ivnbvl Yp P�G.rri- inches MERV (op5onel) Static pressures (OPTIONAL) Cooling coil installed _ v _ N Mode: Hoofing Cooling Continuous Fan Fan speed tap Humidifier bypass _ Open _Closed All registers open 1...,_ Anw..n... n, — P=- AP filter = P-- p=+ Pei AP AC coil AP Total ESP =. Cooling: Measured air flow through Indoor coil using flow grid N)A -- no AC system installed Design cooling airflow NQ CFM 5000' Target airflow limits (design +1- 15%)' ' ��•")(, f to '�, (,, CFM 5000' i`;;(;Measured airflow •. Yjh Cooling fan speed tap Flow grid plate size -r Temperature of air through F Indicated flow to Volumetric now multiplier measurement tool Q 5000', air temporaturerr�tt. NSOPC Pa TFSOP Pa Flow Resistance Correction Facto Measured uhno�w, no adjustments or correction �CFM Adjusted (indicated) airtlaw �CFM Volumetdeilowl 5000' ❑ Pass IOr V..., Fail JCFM Heating: Gas manifold pressure OEM mandold pressure IWC Target manifold Omits +l-5%) `;,Zto.?�. . 31 specification, 5000' pressure (spec - WC Measured manifold pressure IWC Pass r •., LL:.tFotl Heating: Temperature rise :i OEM temperature rise Omits `, `l '� ? i F / _r'toa I i_) .' Measured temperature rise r: Return air G � F Supply air (3 3 F j i•� Ternp rise '/( F ` y0] `7 ......, Pass `[]°) Fall( Caution:Ternp rise within 10 F top :. of of range MwheN®I SwWris Pail mmw Tosteg SubMWAI FN V2o12e6o3 3 or 0 (This section under development, not yet being enforced) 'Reqlster air flows All rogislets ore cut through finish materials and moving air (Remainder of section under development, not yet being enforced) Pressure balance Pressor a difference limit, room -to -core Pa 4v Pass ,Q', Fait I W—V Room Maaeured pressure pass Fail drop (Pa) El ............. 01 0 114, Me&.,"j SYOEMS Pa'or Ce letang S'b"41'd V"' V20120608 4 of 8 �binbustlan;Safety: wa� xr - .e.xnmu....aa:t 2. �INIA no natural draft combustion appliances Outdoor temperature F Worst -case depressukutiontesting House setup appliances _ # of bath fans on. These doors are dosed: —Vented range hood on —Clothes d"i'06 Air handler oh. Other fans on - Appliance Typf Loeatioi saute iepressurizatlon ilmit Po wrt outside surad not CAZ depressurization Pa wn outside less negative) I Caution (more negative) �" L;. BPI maximum limit seconds , Measured spillage duration seconds :pr Pass = duration not exceeding limit Draft pressure a ;R BPI limit Pa wrt CAZ Measured Po wrt CAZ F t Pass a pressure more negative than limit -'.CO concenl�stion in undiluted flue gas BPI maximum limit ppm Measured CO ppm aY x. '! I"ass - CO level not exceeding limit Caution=CO level 25 to 1pg ppm Draft -hood �Inducaddrah Draft -hood - `Induceddrall Draft -hood Induced -draft ( hhr El OK '❑ Caution ❑ OK ❑. Caution t ❑, OK❑J Caution 60 68 60 y ❑ Pass f� Fail ❑ 'Pass E] Fall ; ❑'. Pass i❑i Fail ❑ Pass ,�l Fail ❑ Pass ;'t"l� Foil ❑ : Pass j Fail ❑ Pass 'n Fail ❑ Pass T5 Fail ❑ Pass "{'�• fall _❑-'Caution •. ❑; I Caution ❑ Caution Mechanical Systoma Porformanm T avMg Submew Fmm V20120600 5 of s System controls operating per design intent stem Pass Pail Locaieaieust ,.. Whcle-house ventilation Sub•strLcturai floor exhaust Healing in -9 Coaling slefl0�tif@S B ll ! } qiq q z 1'Sp t i Ap . S E yt '. § }'^ JL Approved Agency (technician performing inspection and testing documented on this form) `'',, Name (Pont) Title Company Signature and Data • r 0 (%/ .SPA SOn - (••!✓.�y 'f-(n ,c- FiVAC contractor (Fort Collins license holder) Company ';.Signatureand Date Madwmml 8ysuaens For'zmanW To%Wg Sw TdW Form V2912G311.6 auto