Loading...
HomeMy WebLinkAbout5751 Big Canyon Dr - Disclosures/Blower Door Test - 11/11/2013BUILDING LEAKAGE TEST Energy Logic Date of Test: 11/11/2013 Test File: Untitled Customer: Ryland Homes Technician: Aaron Scott Project Number: 29436 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve Building Address: 5751 Big Canyon Dr Fort Collins, CO 80522 1580 CFM50 2.28 ACH50 86.9 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 124.2 Exponent (n) = 0.650 (Assumed) 4. Test Settings: Test Standard: RESNET One -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate 2. Estimated Design Infiltration Rate Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 107.1 CFM 0.15ACH 17.8 CFM per person Winter: 173.3 CFM Summer: 108.7 CFM 0.25 ACH 0.16 ACH BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 11/11/2013 Test File: Untitled Building Information Location Climate Information Volume 41612 Surface Area 9966 Floor Area 4326 Height 33 # of Bedrooms 5 # of Occupants 6 Year of Construction 2013 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 36005-7 11/15/2012 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 11/11/2013 Test File: Untitled Depressurization Test: Environmental Data Indoor Temperature (OF) Outdoor Temperature (°F) Altitude (ft) 71.0 45.0 5280.0 Baseline Pressure Data Baseline 1 (Pa) -10.0 Baseline 2 -8.8 Baseline 3 -10.0 Baseline 4 -9.4 Baseline 5 -9.2 Average Baseline (Pa) -9.5 Baseline Range (Pa) 1.2 Data Points Nominal Baseline Adjusted Fan Building Pressure Building Pressure Pressure (Pa) (Pa) (Pa) Nominal Adjusted Flow Flow Fan (cfm) (cfm) Configuration -58.9 49.4 77.9 1589 1568 Ring A Time Averaging Period: 10 Deviations from Standard RESNET One -Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 11/11/2013 Test File: Untitled Comments House to garage connection: 49pa. Connection to mechanicals: -50pa