Loading...
HomeMy WebLinkAbout5727 Big Canyon Dr - Disclosures/Blower Door Test - 10/22/2013BUILDING LEAKAGE TEST Date of Test: 10/22/13 Test File: 5727 Big Canyon Dr-Tectite 4 Customer: Ryland Homes Technician: Justin Heldenbrand Project Number: 29344 5��'ogyf Building Address: 5727 Big Canyon Dr Fort Collins, CO 80522 Test Results 1. Airflow at 50 Pascals: 1736 CFM50 (+/- 0.3 %) (50 Pa = 0.2 w.c.) 2.58 ACH50 2. Leakage Area: 95.5 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 127.4 (+/- 7.5 %) Exponent (n) = 0.668 ( +/- 0.019 ) Correlation Coefficient = 0.99961 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 101.3 CFM 0.15ACH 20.3 CFM per person Winter: 190.4 CFM Summer: 119.5 CFM 0.28 ACH 0.18 ACH Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: 73.4 CFM Base Rate: 80.8 CFM Infiltration Credit: <7.4 CFM> BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 10/22/13 Test File: 5727 Big Canyon Dr-Tectite 4 Building Information Location Climate Information Volume 40456 Surface Area 8591 Floor Area 4326 Height 20 # of Bedrooms 4 # of Occupants 5 Year of Construction 2013 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) IDefault Micromanometer Energy Conservatory DG700 1 275-6 03/20/08 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 10/22/13 Test File: 5727 Big Canyon Dr-Tectite 4 Depressurization Test: Environmental Data Indoor Temperature (OF) Outdoor Temperature (OF) Altitude (ft) 67.0 48.0 5003.0 Data Points Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -0.9 n/a n/a -67.8 -67.3 141.5 2127 2117 -0.0 Ring A -64.7 -64.2 133.4 2066 2056 0.3 Ring A -62.2 -61.6 124.9 2001 1991 -0.3 Ring A -58.3 -57.8 114.1 1915 1906 -0.3 Ring A -55.0 -54.5 106.9 1855 1846 0.4 Ring A -50.5 -49.9 94.5 1747 1739 0.2 Ring A -47.4 -46.8 85.7 1665 1657 -0.3 Ring A -44.1 -43.6 78.2 1592 1585 0.1 Ring A -0.1 n/a n/a Time Averaging Period: 0 Deviations from Standard RESNET Multi -Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 10/22/13 Test File: 5727 Big Canyon Dr-Tectite 4 Comments Connection to: Mechanicals -50pa Garage -47.1 pa