Loading...
HomeMy WebLinkAbout2244 Thoreau Dr - Disclosures/Blower Door Test - 11/16/2013BUILDING LEAKAGE TEST Thermal Concepts 6617 S. College ave Fort Collins, CO 80525 Date of Test: 11-16-13 Test File: Journey Homes 2244 Thoreau Dr -BD Customer: Journey Homes Technician: Paul Higman Project Number: Greeley, CO 80634 Building Address: 2244 Thoreau Dr Fort Collins, CO 80524 Test Results 1. Airflow at 50 Pascals: 1118 CFM50 (+/- 0.9 %) (50 Pa = 0.2 w.c.) 2.33 ACH50 0.3630 CFM50/ft2 floor area 2. Leakage Areas: 121.6 in2 ( +/- 4.0 %) Canadian EgLA @ 10 Pa 66.7 in2 (+/- 6.4 %) LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 99.8 ( +/- 10.1 %) Exponent (n) = 0.618 ( +/- 0.027 ) Correlation Coefficient = 0.99342 4. Test Settings: Test Standard: CGSB Test Mode: Depressurization Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 53.7 CFM 0.11 ACH 2. Estimated Design Infiltration Rate: Winter: 84.4 CFM Summer: 49.8 CFM 0.18 ACH 0.10 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 11-16-13 Test File: Journey Homes 2244 Thoreau Dr-BD Building information Location Climate Information Volume 28769 Ventilation Weather Factor 0.87 Surface Area Energy Climate Factor 17.00 FloorArea 3080 Heating Degree Days 6020 Height 8 Cooling Degree Days 287 #of Bedrooms 2 Design Winter Wind Speed 9.0 mph #of Occupants Design Summer Wind Speed 7.0 mph Year of Construction 2013 Design Winter Temp Diff 69 deg F Wind Shield M Design Summer Temp Diff 16 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency% Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 ' Date of Test: 11-16-13 Test File: Journey Homes 2244 Thoreau Dr-BD Depressurization Test: � Environmental Data Indoor Temperature (A°F) Outdoor Temperature(A°F) 67.0 46.0 Data Points -Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -1.1 n/a n/a -61.5 -60.2 � 48.1 1257 1232 -1.8 Ring A -55.7 -54.4 42.4 1182 1158 -1.7 Ring A -49.8 -48.5 40.0 1149 1126 2.6 Ring A -45.6 -44.3 332.0 1077 1055 1.7 Ring B � -40.1 -38.8 284.7 998 978 2.3 Ring B -35.1 -33.8 234.2 906 888 1.1 Ring B -31.5 -30.2 181.8 799 783 -4.4 Ring B -24.7 -23.4 148.1 722 707 1.1 Ring B -20.1 -18.8 104.4 607 595 -2.7 Ring B -1.5 n/a n/a Deviations from Standard CGSB-Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 11-16-13 Test File: Journey Homes 2244 Thoreau Dr-BD Comments House wrt Garage = -46.2 pa