Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
944 Ridge Runner Dr - Disclosures/Final Energy - 11/15/2013
BURGESS DR Horton 1685 944 Ridge Runner Drive Fort Collins, CO 80524 (.'0N UL'IUN'rs INC 5 Stars Plus Confirmed Uniform Energy Rating System Energy Efficient 1 Star 1 Star Plus 2 Stars 2 Stars Plus 3 Stars 3 Stars Plus 4 Stars 4 Stars Plus 5 Stars 5 Stars Plus 500-401 400-301 300-251 250-201 200-151 150-101 100-91 90-86 85-71 70 or Less HERS Index: 66 Conditioned Area: 2627 sq. ft. Conditioned Volume: 23012 cubic ft. Bedrooms: 3 Efficient Home Comparison: 34% Better HouseType: Single-family detached Foundation: Conditioned basement Heating: Fuel -fired air distribution, Natural gas, 92.0 AFUE. Cooling: Air conditioner, Electric, 13.0 SEER. Water Heating: Conventional, Natural gas, 0.62 EF, 40.0 Gal. Duct Leakage to Outside: 0.00 CFM25. Ventilation System: Exhaust Only: 56 cfm, 11.3 watts. Programmable Thermostat: Heating: Yes ICooling: Yes Ceiling Flat: R-38 Slab: R-0.0 Edge, R-0.0 Under Sealed Attic: NA Exposed Floor: R-30 Vaulted Ceiling: NA Window Type: Double - Vinyl 3430' Above Grade Walls: R-15, R-19 Infiltration Rate: Htg: 949 Clg: 949 CFM50 Foundation Walls: R-19.0 Method: Blower door test Percent Interior Lighting: 10.00 Range/Oven Fuel: Natural gas Percent Garage Lighting: 0.00 Clothes Dryer Fuel: Natural gas Refrigerator (kWh/yr): 775.00 Clothes Dryer EF: 2.67 Dishwasher Energy Factor: 0.68 Ceiling Fan (cfm/Watt): 0.00 The Home Energy Rating Standard Disclosure for this home is available from the rating provider. REM/Rate - Residential Energy Analysis and Rating Software v14.3 . This information does not constitute any warranty of energy cost or savings. © 1985-2013 Architectural Energy Corporation, Boulder, Colorado. Registry ID: 746848974 Rating Number: 1207201001 YK Certified Energy Rater: Robert Hutchinson Rating Date: 11/15/2013 Rating Ordered For: DR Horton Estimated Annual Energy Cost Confirmed Use MMBtu Cost Percent Heating 72.5 $499 36% Cooling 2.4 $62 5% Hot Water 19.2 $125 9% Lights/Appliances 30.8 $681 50% Photovoltaics -0.0 $-0 -0% Service Charges $0 0% Total 124.9 $1367 100% i a i 3 ''� .E S: l", 1 csse t ,� i � ., ui si -v.. _ „a s e s. » ,.. ,.. ...„...fdl BURGESS FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT Date: November 15, 2013 Rating No.: 1207201001 YK Building Name: DR Horton 1685 Rating Org.: BCCI-Burgess Inc. Owner's Name: DR Horton Phone No.: 303-300-4527 Property: 944 Ridge Runner Drive Rater's Name: Robert Hutchinson Address: Fort Collins, CO 80524 Rater's No.: 7479033 Builder's Name: DR Horton Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 944 Ridge Runner Drive.blg Rating Date: 11/15/2013 Annual Energy Cost ($) FC 2012 As Designed Heating: 573 581 Cooling: 98 82 Water Heating: 124 124 SubTotal - Used to Determine Compliance: 795 787 Lights & Appliances: 692 681 Photovoltaics: -0 -0 Service Charge: 0 0 Total: 1487 1468 Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.400 0.340 Home Infiltration (Section 402.4.2): Duct Leakage (Section 403.2.2): PASSES PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses th uirements by 0.9%. Name: Robert Hutchinson Signature: 7479033 Organization: BCCI-Burgess Inc. Date: November 15, 2013 " Design energy cost is based on the following systems: Heating: Fuel -fired air distribution, 60.0 kBtuh, 92.0 AFUE. Cooling: Air conditioner, 36.0 kBtuh, 13.0 SEER. Water Heating: Conventional, Gas, 0.62 EF. Window -to -Floor Area Ratio: 0.13 REM/Rate - Residential Energy Analysis and Rating Software 04.3 This information does not constitute any warranty of energy cost or savings. © 1985-2013 Architectural Energy Corporation, Boulder, Colorado. FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT DR Horton 1685 Page 2 Blower door test: Htg: 949 Clg: 949 CFM50 . In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate - Residential Energy Analysis and Rating Software 04.3 This information does not constitute any warranty of energy cost or savings. ©1985-2013 Architectural Energy Corporation, Boulder, Colorado.