HomeMy WebLinkAbout926 Ridge Runner Dr - Disclosures/Mechanical - 10/02/2013City of Fort Collins Residential Mechanical Systems Performance Report This form is a record of testing targets and results, Yitn Pass/Fail outcomes, For information on measurement tools end testing techniques, we the "Residential New Construction Mechanical Systems Testing Guide." The guide and this form may, be periodically updated: check the Building Services web Site for the current version. This form must be completed and signed by an "Approved Agency." and submitted to Building Services as a requirement for recervIng a C.O. Color key Measured value to,i comp" with target or pass IN '14"Fe: Other data Both exhaust ,I]Flow box Flow co l8f measurement method Passive flow hood Pilot tube inverse Nrflow v Pilot l2oh0811-a—lelac Temperature of air through indicated flow to Vulunictr c flow MU measurement toot F TD SOUCY, a:?lempPr t 'X Measured Exhaust Anflow Operation Minimum Design Indicated Exhaust Pickup Location Intermittent or Airflow Requirement Airflow (CFM Flow Volumetric Flow (CFM 5,00') Pass Fail Continuous (CFNI 5000') 5000') (CFMI YIntemrs! Contin -&Intermit Con In M ks�- ee _&ntenrif _Can in 51, Q%k, 01 4e, intermitcritin I ,v 'A tt Intermit Contra "A' Intermit Conlin intermit Conlin Intermit —Conlin Kitchen exhaust Oven futtl Exhaust airflow Operation irtemittent Continuous, M� NIA - Kitchen hood does not vont outside Minimum Oxnaust Airflow rbnUrreW6raF-7---7---' -'7CFM50oV Measured willow Airflow measurement methodi —Flow box Flow mliar Passive flow hoad Not Woo traverse indicated liow to Volumesic filovi mullipile Temperature of air through F measurement tool 500U, sit to Indicated flow CFM Volumetric flow SCFM 5000' pa" Testing notes (fan speed. masking, flow out of range, Wixsar,loot Syssinrs Perfo.miame Ttstmij SublinriUl Fa-rs V20=Aaa 1 rle 11 Systems other than sub -structural floor exhaust Minimum exhaust airflow requirement '-� rr r J_ CFM SOOTY r3 �}. Indicated to Measured Airflow ' {{ Volumetric Design Airflow i Measuramentt Measurement Location * Flow Indicated Flow Volumetric .(CFM 5000') Method } Air Tam aratura F P O Multiplier (CFM) ) Flow r Pass/Fail (CFM 50001 YY� xr-low hex t , U tN/Gt �- t' .. ... ���. ? - Total exhaust airflow � , — Pa951vB flow hood collar '^7 • � : an _.Flow Pilot tube tmvorse r _Flow collar. ._ (, -7 s Total suppiy airflow �� _ Pilot tube traverse ❑` Flow box ( —_ Passive flaw hood For systems in which suppiy airflow is circulated by the air handier fan, fan speed for measurement —Heat Cooling Continuous tan A; Balanced airflow in balanced systems .a Average of measured supp''y Target flow range "ems and exhaust flowsCF11A5000' (average I15°5):r_', r. to `; CFM 5000' PASS Sub -structural floor exhaust ( NIA- no sub -structural nocr exhaust system A Design airflow, cr-M song• I ;r Measured airflow —Flow. box —_Flow collar ` - Airticw measurement method l--P—assive flow ho-odd-� Not tuba traverse 7emperemeature u air measurement thrtoo! F Indicated flrnv to Volumetric flow rnuitip!iar� measurement tcc. @ 5000% air tempamture Indicated flow CFM Volumetricnow r CFM �000' (�- Pas 't.J Fail NIP. -- no duchvork or no ductwork outsideoamdltioned space House conditioned floor areaat Temperature of air through r meaailroment tool Indicated now to Volumetricrow multiplier. @ 5000',air temperature Maximum Allowed Duct Leakage Measured Duct Leakage i f-_ Test Parameter and Conditions Normalized Leakage g Abeolute Leakage Indicated Fiow - Volumetric Flow ' n Measure mant Timing Air Handler (CFM25 i 100 all (CFM25) (CFM25) (CFM25 5000) Pass/Fail ;". To Rough-in �Exdudeo q I-� � _ k . Total'eakage Rough -in included Total leakage Complete 1!!ciuded 12 '? { J.-^_, -'� Leakage to outdoors Complete Included & �.'� ❑ Gv. Wi h,tnir) systems Parlomanw lent»a suhmktal Fcnn 1410120e 8 2 tl, 6 Filter type i Grand (� ` V Type Ystylo P) .(.. Thickness�t linches MERV(optional)i Static pressures (OPTIONAL) ms Cooling coil installed _ Y _ N ,i � a Mode: _Heating _Cooling Continuous Fan Fan speed tap i Humidifier bypass Open _Closed _ All registers open yd i P= AP filter = .,k il?rz Z-. P = Y �� P=+ P=i �l dP AC coil = Cooling: Measured air flow through Indoor coil using flow grid ( N)A- no AC system installer Design cooling airflow CFPA 5000' Target airflow limits (design +i 15°h) to CFM 5000' Measured airflow 4 s Cooling ton speed top—�—, Flow grid plate size Temperature o`: air through 1F InniCated flow to Vvl t multiplier� mea - measurement tool _. JI 1)00' r to �q SWO', air temperature NSOP= Pa TFSOP[ Pa Flmv Resistance Correction Factor--•-1 Measured airflow, no adjustments or correct �CFM Adjusted (indicated) airflau CFM } Volumetric flow 5000' ❑ Pass i;�t Fail J, Heating: Gas manifold pressure OEM manifold pressure 'S - ;', specification, 5000' 3 IWC Target manifold pressure Lmfts (spec tl• 5%) �� Zm .IWC - Measured manifold pressure IWC Pass t�.❑ «,,,et�,Fail ,�t Heating: Temperature rise OEM :emperture rise limits +(� fo .:��`>`F `Measured temperature rise >``'• Return air f.=qf F Supply air (,r jF . t Tamrise/ F Caution: Temp rise within { 10 F of tap at range Vn nlcml Systems Penermanca Tnw,p suemet9l =am V2012e608 a m a (This section under development, not yet being enforced) Register air flows All registers are cut throughfinish materials and air (Remainder of section under development, not yet being enforced) Pressure balance `' Pressure difference limit. room-to-cofe to +3- ""° Pa n� Pass ', t:7 a Fail Room Measured pressure Pass Fail drop (Pa) rn�s+w n t y B i t.(� 9 ' ;tee ❑ f n C'LIT Mx t r ❑ rs.z; h Cljj4 �' Y !T Metl�arua! iyS10411 neaformanw Tew.ne subwho Form V2012000e 4 orS ,N NIA - natural draft comoustion app rams Worst -case depressurization testing Housa setup i ( 1 1: p1r ) Outdoor temperature F _ # of both fans on These 8adrs are closed: —Vented range hood on —Clothes dryer on - Air handler on - - Other fans. on I fiA Tested appliances Appliance ( i .1. Type Location CAZ pressure BPI depressurization limit Pa wn outside Measured net CAZ depressurization Pa wrt outside ;i OK (less negative) I Caution imore negative) I , o.Spillage {.Att P? BPI maximum limit seconds Measured spillage duration seconds i - Piss = duration not exceeding limit Draf: pressure'i BPI limit Pa wn CAZ Measured Pa wn CAZ Pass - pressure more negative than limit -' CO concentration in undiluted Sue gas BPI maximum limit pom '-' Measured CO pom Pass - CO level not exceeding limit Caution = CO level 25 to 100 ppm _ Drak-hood Induced-drok Draft-t»cd Induced -draft _ Drak-hood Induoed-draft epee ;w •r= _., " "Tip=, Q OK 1 Q' Caution Q OK I Qy Caufan .Q. 10K [n]Caution ❑- Pas 3Q} Foil Fab Q Pas., yQ} Pail ❑ -FP;SS sQ! Foil Q Pass 3Qf Foil Q PasB ;Q Fair Q Pass `QI Fail Pass -EJ Fail Q Pass iQr Fail Q ' Caution Q. Caution Q:. Caution W hanrcN Stotems Podarmenee Testing S�bm&le: Fern V2020 $0a 6 ore System ou-91rols operating per design intent 5ystom Pass —yet,— Local exhaust TZF% --I. Ifibota-house venNiaticr, IBM Sub -structural Hour exhaust Healing VV- Cooling Approved Agency (technician Performing inspection and testing documented on this form) Name (print) I 13Gr tic, r-,, A qr-c! Title 'Te ch S 14c Girmature and Daw HVAC contractor (F Name (poet) Company Slqnaturo and Dale v2r.r2wh act C,