HomeMy WebLinkAbout5115 Cinquefoil Ln - Disclosures/Blower Door Test - 11/04/2013 (2)BUILDING LEAKAGE TEST Date of Test: 11 /04/13 Customer: Village Homes Test Results 1. Airflow at 50 Pascals (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: Test File: 5115 Cinquefoil Ln-Tectite 4 Technician: Justin Heldenbrand Project Number: 29626 Building Address: 5115 Cinquefoil Ln Fort Collins, CO 80528 1151 CFM50 (+/- 0.7 %) 1.89 ACH50 63.3 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 76.2 (+/- 15.0 %) Exponent (n) = 0.694 ( +/- 0.037 ) Correlation Coefficient = 0.99857 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 67.1 CFM 0.11 ACH 13.4 CFM per person Winter: 126.2 CFM Summer: 79.2 CFM 0.21 ACH 0.13 ACH Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: 73.1 CFM Base Rate: 73.1 CFM Infiltration Credit: <0.0 CFM> BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 11/04/13 Test File: 5115 Cinquefoil Ln-Tectite 4 Building Information Location Climate Information Volume 36491 Surface Area 8406 Floor Area 3556 Height 20 # of Bedrooms 4 # of Occupants 5 Year of Construction 2013 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 275-6 03/20/08 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 11/04/13 Test File: 5115 Cinquefoil Ln-Tectite 4 Depressurization Test: Environmental Data Indoor Temperature (OF) Outdoor Temperature (OF) Altitude (ft) 70.0 39.0 1 5003.0 Data Points Nominal Baseline Adjusted Fan Building Pressure Building Pressure Pressure (Pa) (Pa) (Pa) Nominal Adjusted Flow Flow Fan (cfm) (cfm) � % Error Configuration -3.8 n/a n/a -70.7 -68.2 66.0 1466 1432 0.3 Ring A -67.6 -65.1 61.3 1414 1382 -0.1 Ring A -65.0 -62.5 57.7 1374 1342 -0.1 Ring A -60.1 -57.6 52.0 1305 1276 0.4 Ring A -58.2 -55.7 48.1 1256 1228 -1.0 Ring A -53.4 -50.9 43.0 1189 1162 -0.2 Ring A -51.5 -49.1 41.6 1171 1144 0.7 Ring A -47.9 -45.4 36.7 1101 1076 -0.0 Ring A -1.2 n/a n/a Time Averaging Period: 0 Deviations from Standard RESNET Multi -Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 11/04/13 Test File: 5115 Cinquefoil Ln-Tectite 4 Comments Connection to: Mechanicals -50pa Garage-47.8pa