HomeMy WebLinkAbout508 W Trilby Rd - Special Inspections/Engineering - 07/09/2013r 4>CENTER L I N E 16360 Table Mountain Parkway, Golden, CO 80403 July 9, 2013 Ms. Bennie Williams MasTec RE: DN13XC322 "Good Samaritan Retirement" Antenna Mount Analysis Dear Ms. Williams: Centerline Solutions performed a structural review of the existing antenna mounts at the above referenced site. The existing antenna mounts can safely support the existing CDMA and new Network Vision antennas and equipment. Additional ballast is required for the new NV antennas and equipment. The total ballast load shall be (14) 35 lb CMU hollow blocks evenly distributed on the antenna frame. The centerline of the antennas shall not exceed 6' AR-L. The safety factor for the temporary full equipment load is 1.15 and for the NV only it is 1.57. All antennas and equipment shall be placed on the building as shown in the drawings issued by this office. Please contact us with any questions. Sincerely,Pjp REG/s� ;Io�•�aER JAhf<�s F�Fo 346�0 �r Khristopher Scott, PE r, . fAMO <cc ATT: Calculations j' `��;0�ONAL`����` JUL 0 9 2013 'CENTERLINE Design of Equipment - IBC 2009 Loads Antennas Want:= 12in Aant Want'hant DN13XC322 7/8/13 psf := lb ft2 sf := ft2 hant = 6ft dant-= 6in lb psi := Aant = 6 ft2 in Pipe Mount dp;pe := 2.875in Lp;pe := 12ft spacs pp := 5ft Sp;pe := 1.061 in Antenna Support Design Wind Design h := 50ft LV := 100 mph �Ezp B _ I := 1.0 KZ := .81 . Kd :_ .90 Table 6-5 Kzt 1 Ib 2 lb qZ := .00256 — • KZ KZt • Kd • V I qZ = 18.662 - G := .85 ft2 ft` Cf := 1.4 Panel p := qZ G Cf p = 22.208 Ib Design Wind Pressure tie