Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3650 Voyager Ln - Disclosures/Final Energy - 09/25/2013
0 energyLogic www msrpytopu.00�r 59049 Ra&� Village Homes •l/{ V' 3650 VoyagerLn Fort Collins, CO 80528' r 5 Stars Plus Confirmed RegistrylD: 532697978 Rating Number: 29291 Certified Energy Rater: Justin Heldenbrand Rating Date: 9/25113 Rating Ordered For: Village Homeowner Estimated Annual Energy Cost Confirmed Use MMBtu Cost Percent Heating 65.5 $455 31% Coolin 15 $38 3% Uniform Energy Rating System Energy Efficient 9 1 Star 1' Star Plus 2 Stars 2 Stars Plus I 3 Stars 3 Stars Plus a Stars 4 Stars Plus 5. Stars 5 Stars Plus Hot Water 19.4 $126 8% - -�-- Lights/Appliances 27S $666 45% 500-401 400-301 300-251 250-201 200-151 150-101 100-91 90-86 85-71 70 or Less I Photovoltaics -0.0 $-0 -0% HERS Index: 61 Service Charges $204 14% ��? General Information `" Total 113.9 $1490 100% Conditioned Area: 3136 sq. ft. House Type: Single-family detached Conditioned Volume: 30159 cubic ft. Foundation: More than one type Bedrooms: 3 This home meets or exceeds the minimum Mechanical Systems Features criteria for all of the following: 2001 International Energy Conservation Code Heating: Fuel -fired air distribution, Natural gas, 93.5 AFUE. 2003 International Energy Conservation Code Cooling: Air conditioner,. Electric, 13.0 SEER. 2004 International Energy Conservation Code Water Heating: Conventional, Natural gas, 0.62 EF, 50.0 Gal. 2006 International Energy Conservation Code Duct Leakage to Outside: 1.00 CFM25. 2009 International Energy Conservation Code Ventilation System: Exhaust Only: 80 cfm, 15.0 watts. Programmable Thermostat: Heating: Yes Cooling: Yes Building Shell Features Ceiling Flat: R-38 Slab: R-0.0 Edge, R-0.0 Under Sealed Attic: NA Exposed Floor: R-43 Vaulted Ceiling: NA Window Type: Low E .34 /.30 Above Grade Walls: R-13, R-20 Infiltration Rate: Htg: 1011 Clg: 1011 CFM50 Foundation Walls: R-11.0 Method: Blowerdoortest Lights and Appliance Features , Home Energy Rating Provider Percent Interior Lighting: 95.00 Range/Oven Fuel: Natural gas EnergyLogic, Inc. Percent Garage Lighting: 0.00 Clothes Dryer Fuel: Electric P.O. Box N;�- Refrigerator (kWh/yr): 691.00 Clothes Dryer EF: 3.01 Berthoud, CO 80513 Dishwasher Energy Factor: 0.60 Ceiling Fan (cfmMatt): 0.00 Phone # 1-800-315-0459 to No. 1199&06,i ,F The Home Energy Rating Standard Disclosure for this home is available from the rating provider. wwwmrglogie.com REM/Rate - Residential Energy Analysis and Rating Software v14.3 _ Justin Helderi7x�aAldonlr�" This information does not constttule any warranty of energy cost or savings. � *k&j ..d 2013.09.26 09:38:d7 `Yi6'00' © 1985-2013 Architectural Energy Corporafion, Boulder, Colorado. Certified Energy Rater A GnergyLogic P „Na 190B-069� 3 tam analysis. Insight. answers. 2012 IECC ANNUAL ENERGY COST COMPLIANCE Date: September 26, 2013 Rating No.: 29291 Building Name: Village Homes Rating Org.: EnergyLogic Inc. Owner's Name: Village Homeowner Phone No.: 970.566.6463 1.800.315.0459 Property: 3650 Voyager Ln Rater's Name: Justin Heldenbrand Address: Fort Collins, CO80528 Raters No,: 1088900 Builder's Name: Village Homes Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 3650 Voyager Ln-Village-REM14.3.blg Rating Date: 9/25/13 Annual Energy Cost ($) 2012 IECC As Designed Heating: 450 528 Cooling: 111 61 Water Heating: 125 125 SubTotal - Used to Determine Compliance: 686 714 Lights &Appliances: 679 666 Photovoltaics: -0 -0 Service Charge: 204 204 Total: 1569 1584 Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.480 0.340 Home Infiltration (Section 402.4.1.2): PASSES Duct Leakage (Section 403.2.2): PASSES Mechanical Ventilation (Section 403.5): PASSES This home DOES NOT meet the annual energy cost requirements of Section 405 of the 2012 International Energy Conservation Code based on a climate zone of 5B. The 2012 IECC Mandatory Requirements have not been verified. Name: Justin Heldenbrand Organization: EnergyLogic Inc. * Design energy cost is based on the following systems: Heating: Fuel -fired airdistribution, 84.0 kBtuh, 93.5AFUE. Cooling:Air conditioner, 36.0 kBtuh, 13.0 SEER. Water Heating: Conventional, Gas, 0.62 EF. Signature: Date: September 26, 2013 REM/Rate - Residential Energy Analysis and Rating Software 04.3 This information does not constitute any warranty of energy oost or savings. ©1985-2013Architectural Energy Corporation, Boulder, Colorado. 2012 IECC ANNUAL ENERGY COST COMPLIANCE Village Homes Page 2 Window -to -Floor Area Ratio: 0.12 Blower door test: Htg:1011 CIg:1011 CFM50 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2012 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate - Residential Energy Analysis and Rating Software v14.3 This information does not constitute any warranty of energy cost or savings. ©1985-2013Architectural Energy Corporation, Boulder, Colorado. No Text nergyLogic v¢; ' P ; �Ni 1Y960691' 3 ' analysis. Insight. answers. �RCIT iM~N` FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT Date: September 26, 2013 Rating No.: 29291 Building Name: Village Homes Rating Org.: EnergyLogic Inc. Owner's Name: Village Homeowner Phone No.: 970.566.6463 1.800.315.0459 Property: 3650 Voyager Ln Rater's Name: Justin Heldenbrand Address: Fort Collins, CO80528 Rater'sNo.: 1088900 Builder's Name: Village Homes Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 3650 Voyager Ln-Village-REM14.3.big Rating Date: 9/25/13 Annual Energy Cost ($) FC 2012 As Designed Heating: 511 528 Cooling: 95 54 Water Heating: 125 125 SubTotal - Used to Determine Compliance: 732 708 Lights &Appliances: 679 666 Photovoltaics: -0 -0 Service Charge: 204 204 Total: 1614 1578 ' Window LI-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.400 0.340 Home Infiltration (Section 402.4.2): PASSES Duct Leakage (Section 403.2.2): PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses ft requirements by 3.3%. Justin Heldenbrand Name: Justin Heldenbrand Signature: 2013.09.26 09:37:40 -06'00' Organization: EnergyLogic Inc. Date: September 26, 2013 ' Design energy cost is based on the following systems: Heating: Fuel -fired air distribution, 84.0 kBtuh, 93.5AFLIE. Cooling: Air conditioner, 36.0 kBtuh, 13.0 SEER. Water Heating: Conventional, Gas, 0.62 EF. Window -to -Floor Area Ratio: 0.12 REM/Rate - Residential Energy Analysis and Rating Software v14.3 This information does not constitute any warranty of energy cost or savings. ©1985-2013Architectural Energy Corporation, Boulder, Colorado. FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT Village Homes Page 2 Blower door test: Htg:1011 CIg:1011 CFM50 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate - Residential Energy Analysis and Rating Software v14.3 This information does not constitute any warranty of energy cost or savings. ©1985-2013Architectural Energy Corporation, Boulder, Colorado. HOME ENERGY PERFORMANCE 'No. �99&069J �� 0�0 �D1TAT10�D' Estimated Annual Energy Cost S/yr 1500 - 1489.6 k 1000 I 666.2 500 455,0 _ I 38.4 1260 I 204.0 is $ m = = m ti t U Q U c 3 � a y Name: Village Homes Address: 3650 Voyager Ln Fort Collins, CO 80528 House Type Single-family detached Cond.Area: 3136 sq.ft. Rating No.: 29291 Issue Date: September 26, 2013 Certification Verified ENERGY RATING CERTIFICATE HERS® Index Q More Energy 150 140 Existing Homes 130 120 Standard New Home 110 100 90 8o 70 This Home] so 61 50 40 30 20 Zero Energy Home 10 0 Less Energy Annual Estimates': Electric(kWh): 8057 Natural gas(Therms): 864 CO2 emissions(Tons): 12 Annual Savings $1156 `Based on standard operating condition "Based on a HERS 130 Index Home QnergyLogic analysis. In I ght. ansrers. Estimated Annual Energy Consumption MMBtutyr 140 120 100 80 65.5 60 40 20 1.5 0 = U Home Energy Rating Provider Energy Logic, Inc. PO. Box N Certified Rater: Justin Heldenbrand Rater ID: 1088900 Registry ID: 532697978 Rating Date: 9125/13 Signature:1,- tb ss,�4698-el Justin Heldenbrahr; 2013.09.26 09:38:29 -06'00' REWRate - Residential Energy Analysis and. Rating Software v14.3 This information does not constitute any warranty of energy cost or savings. 01985-2013 Architectural Energy Corporation, Boulder, Colorado. The Home Energy Rating Standard Disclosure for this home is available from the rating provider. RESNET HOME ENERGY RATING Standard Disclosure For home located at: 3650 Voyager Ln City: FortCollins State: CO 1. I-X� The Rater or the Rater's employer is receiving a fee for providing the rating on this home. 2. K] In addition to the rating, the Rater or Rater's employer has also provided the following consulting services for this home: A. Mechanical system design B. Moisture control or indoor air quality consulting C. Performance testing and/or commissioning other than required for the rating itself I "� D. Training for sales or construction personnel ❑ E. Other (specify below) 3. L"J The Rater or Rater's employer is: ❑ A. The seller of this home or their agent B. The mortgagor for some portion of the financed payments on this home C. An employee, contractor or consultant of the electric and/or natural gas utility serving this home 4. F The Rater or Rater's employer is a supplier or installer of products, which may include: HVAC systems Thermal insulation systems Air sealing of envelope or duct systems Windows or window shading systems Energy efficient appliances Construction (builder, developer, construction contractor, etc.) Other (specify below): Installed in this home by: El Rater 171 Employer Rater Employer Rater Employer Rater ❑ Employer CIRater ❑ Employer Rater 1-1 Employer Rater u Employer OR is in the business of: Rater Employer Rater Employer Rater Employer Rater Employer Rater Employer Rater Employer ❑ Rater a Employer I attest that the above information is true and correct to the best of my knowledge. As a Rater or Rating Provider I abide by the rating quality control provisions of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy Services Network (RESNET). The national rating quality control provisions of the rating standard are contained in Chapter One 4.C.8 of the standard and are posted at http://www.natresnet.org/accred/standards.pdf. This home may have been verified under the provisions of Chapter Six, Section 603, 'Technical Requirements for Sampling" of the Standard. Justin Heldenbrand Rater's Printed Name Justin Heldenbrand 2013.09.26 09:38:52-0600' Rater's Signature 1088900 Certification # September 26, 2013 Date RESNET Form 0300-2 2. �H energyLogic P . 1Y9B-089 analysis. InsIghf. answers. C��OITI.f�Y J AIR LEAKAGE REPORT Date: September 26, 2013 Rating No.: 29291 Building Name: Village Homes Rating Org.: EnergyLogic Inc. Owner's Name: Village Homeowner Phone No.: 970.566.6463 1.800.315.0459 Property: 3650 Voyager Ln Rater's Name: Justin Heldenbrand Address: Fort Collins, CO80528 Rater'sNo.: 1088900 Builder's Name: Village Homes Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 3650 Voyager Ln-Village-REM14.3.blg Rating Date: 9/25/13 Whole House Infiltration Duct Leakage Ventilation Blower door test Heating Cooling NaturalACH: 0.12 0.09 ACH @ 50 Pascals: 2.01 2.01 CFM @ 25 Pascals: 644 644 CFM @ 50 Pascals: 1011 1011 Eff. Leakage Area: [sq.in] 55.5 55.5 Specific Leakage Area: 0.00012 0.00012 ELA/100sfshell: [sq.in] 0.84 0.841 Leakage to Outside Units _ CFM @ 25 Pascals: _main 1 CFM25 / CFMfan: 0.0005 CFM25 / CFA: 0.0003 CFM per Std 152: N/A CFM per Std 152 / CFA: N/A CFM @ 50 Pascals: 2 Eff. Leakage Area: [sq.in] 0.09 Thermal Efficiency: N/A Total Duct Leakage Units CFM25/CFA Total Duct Leakage: 0.0003 Mechanical: Exhaust Only Sensible Recovery Eff. (%): 0.0 Total Recovery Eff. (%): 0.0 Rate (cfm): 80 Hours/Day: 18.4 Fan Watts: 15.0 Cooling Ventilation: No Ventilation ASHRAE 62.2 - 2010 Ventilation Requirements For this home to comply with ASHRAE Standard 62.2 - 2010 Ventilation and Acceptable IndoorAir Quality in Low -Rise Residential Buildings, a minimum of 61 cfm of mechanical ventilation must be provided continuously, 24 hours per day. Alternatively, an intermittently operating mechanical ventilation system may be used if the ventilation rate is adjusted accordingly. For example, a 123 cfrn mechanical ventilation system would need to operate 12 hours per day, as long as the system operates to provide required average ventilation once each hour. REM/Rate - Residential Energy Analysis and Rating Software v14.3 This information does not constitute any warranty of energy cost or savings. ©1985-2013 Architectural Energy Corporation, Boulder, Colorado. r� (qnergyLogic ,ram � w MO 1%6080 analysts. Insight. answers. Gfy1T�TOM COMPONENT LOAD SUMMARY Date: September 26, 2013 Rating No.: 29291 Building Name: Village Homes Rating Org.: EnergyLogic Inc. Owner's Name: Village Homeowner Phone No.: 970.566.6463 1.800.315.0459 Property: 3650 Voyager Ln Rater's Name: Justin Heldenbrand Address: Fort Collins, CO80528 Rater'sNo.: 1088900 Builder's Name: Village Homes Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 3650 Voyager Ln-Village-REM14.3.blg Rating Date: 9/25/13 Village Homes HEATING SEASON (MMBtu/yr) Ceilings/Roofs 4.7 Rim/Band Joists 2.0 Above Grade Walls 27.1 Foundation Walls 9.8 Doors 1.0 Windows/Skylights 14.7 Frame Floors 0.7 Crawl Space/Unht Bsmt 0.0 Slab Floors 3.6 Infiltration 4.0 Mechanical Ventilation 9.3 Ducts 0.0 Active Solar 0.0 Sunspace 0.0 Internal Gains -17.2 Total 59.8 REM/Rate - Residential Energy Analysis and Rating Software 04.3 This information does not constitute any warranty of energy mst or savings. ©1985-2013 Arch tectural Energy Corporation, Boulder, Colorado. COMPONENT LOAD SUMMARY Village Homes Page 2 Village Homes COOLING SEASON (MMBtu/yr) Ceilings/Roofs 0.3 Rim/Band Joists -0.3 Above Grade Walls -1.7 Foundation Walls -1.5 Doors -0.1 Windows/Skylights 1.9 Frame Floors -0.1 Crawl Space/Unht Bsmt 0.0 Slab Floors -1.7 Infiltration -0.3 Mechanical Ventilation -1.1 Ducts 0.0 Active Solar 0.0 Sunspace 0.0 Internal Gains 11.4 Whole House Ventilation 0.0 Total 6.7 REM/Rate - Residential Energy Analysis and Rating Software v14.3 This information does not constitute any warranty of energy cost or savings. ©1985-2013Architectural Energy Corporation, Boulder, Colorado. tApYT4p f N energyLogic � Na 1pp6Y9 ��' analysis. Insight. answers. �fO,TI.Tt� 2005 EPACT ENERGY EFFICIENT HOME TAX CREDIT ( 13-001 ) Date: September 26, 2013 Rating No.: 29291 Building Name: Village Homes Rating Org.: EnergyLogic Inc. Owner's Name: Village Homeowner Phone No.: 970.566.6463 1.800.315.0459 Property: 3650 Voyager Ln Rater's Name: Justin Heldenbrand Address: Fort Collins, CO80528 Raters No.: 1088900 Builder's Name: Village Homes Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 3650 Voyager Ln-Village-REM14.3.blg Rating Date: 9/25113 Normalized, Modified End -Use Loads (MMBtu/year) 2006 IECC 50% Target As Designed Heating: 31.9 37.4 Cooling: 5.0 4.2 Total 36.9 41.6 Envelope Loads (MMBtu/year) 20061ECC 90% Target As Designed Heating: 57.5 60.7 Cooling: 9.0 5.1 Total: 66.4 65.8 This home DOES NOT meet the requirements for the residential energy efficiency tax credits under Section 1332, Credit for Construction of New Energy Efficient Homes, of the Energy Policy Act of 2005 extended to December 31, 2013. Ceiling Flat: R-38 Sealed Attic: NA Vaulted Ceiling: NA Above Grade Walls: R-13, R-20 Foundation Walls: R-11.0 Exposed Floor: R-43 Building Features Slab: R-0.0 Edge, R-0.0 Under Duct: Uninsulated Window: U-Value: 0.340, SHGC: 0.300 Heating Fuel -fired air distribution, Natural gas, 93.5AFUE. Cooling Air conditioner, Electric, 13.0 SEER. Under penalties of perjury, I declare that I have examined this certification, including accompanying documents, and to the best of my knowledge and belief, the facts presented in support of this certification are true, correct, and complete. Name: Justin Heldenbrand Company: EnergyLogic Inc. Address: PO Box N, Berthoud, CO 80513 Signature: Date: September 26, 2013 REM/Rate - Residential Energy Analysis and Rating Software v14.3 This information does not constitute any warranty of energy cost or savings. ©1985-2013Architectural Energy Corporation, Boulder, Colorado. p. GnergyLogic = ,Ma 18B8-089� a� d analysts. Insight. answers. 2009 IECC ANNUAL ENERGY COST COMPLIANCE Date: September 26, 2013 Rating No.: 29291 Building Name: Village Homes Rating Org.: EnergyLogic Inc. Owner's Name: Village Homeowner Phone No.: 970.566.6463 1.800.315.0459 Property: 3650 Voyager Ln Rater's Name: Justin Heldenbrand Address: Fort Collins, CO80528 Rater'sNo.: 1088900 Builder's Name: Village Homes Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 3650 Voyager Ln-Village-REM14.3.blg Rating Date: 9125/13 Annual Energy Cost ($) 2009 IECC As Designed Heating: 604 528 Cooling: 73 54 Water Heating: 125 125 SubTotal - Used to Determine Compliance: 802 708 Lights &Appliances: 679 666 Photovoltaics: -0 -0 Service Charge: 204 204 Total: 1685 1578 ' Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.480 0.340 Home Infiltration (Section 402.4.2): Duct Leakage (Section 403.22): This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code based on a climate zone of 5B. In fact, this home surpasses the requirements by 11.8%. Name: Justin Heldenbrand Signature: Organization: EnergyLogic Inc. Design energy cost is based on the following systems: Heating: Fuel -fired air distribution, 84.0 kBtuh, 93.5 AFUE. Cooling:Airconditioner, 36.0 kBtuh, 13.0 SEER. Water Heating: Conventional, Gas, 0.62 EF. Window -to -Floor Area Ratio: 0.12 Date: September 26, 2013 REM/Rate - Residential Energy Analysis and Rating Software v14.3 This information does not constitute any warranty of energy cost or savings. 01985-2013 Architectural Energy Corporation, Boulder, Colorado. PASSES PASSES 2009 IECC ANNUAL ENERGY COST COMPLIANCE Village Homes Page 2 Blower door test: Htg:1011 Clg:1011 CFM50 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate - Residential Energy Analysis and Rating Software v14.3 This information does not constitute any warranty of energy cost or savings. ©1985-2013 Architectural Energy Corporation, Boulder, Colorado. HOME CERTIFIED TO MEET THE PROVISIONS OF THE 2009 INTERNATIONAL ENERGY CONSERVATION CODE This home built at 3650 Voyager Ln, Fort Collins, CO by Village Homes exceeds the minimum requirements for the 2009 International Energy Conservation Code Ceiling Flat: R-38 Sealed Attic: NA Vaulted Ceiling: NA Above Grade Walls: R-13, R-20 Foundation Walls: R-11.0 Exposed Floor: R-43 Slab: R-0.0 Edge, R-0.0 Under Duct: NA 9/25113 Building Features Dud Leakage to Outside: 1.00 CFM @ 25 Pascals Total Duct Leakage: 1.00 CFM @ 25 Pascals Infiltration: Htg: 1011 Clg: 1011 CFM50 Window: U-Value: 0.340, SHGC: 0.300 Heating Fuel -fired airdistribution, Natural gas, 93.5AFUE. Cooling Air conditioner, Electric, 13.0 SEER. Water Heating Conventional, Natural gas, 0.62 EF, 50.0 Gal. The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in compliance with Chapter 4 based on Climate Zone 513 and with all mandatory requirements. Name: Justin Heldenbrand Organization: EnergyLogic Inc. Signature: Date: September 26, 2013 The 2009 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( '1CC'). No version of this software has been reviewed or approved byICC or its affiliates. REM/Rate - Residential Enemv Analysis and Rating Software v14.3 2009 IECC Certificate 3650 Voyager Ln, Fort Collins, CO 80528 Building Envelope Insulation Ceiling Flat: R-38 Vaulted Ceiling: NA Above Grade Walls: R-13, R-20 Foundation Walls: R-11.0 Exposed Floor: R-43 Slab: R-0.0 Edge, R-0.0 Under Infiltration: Htg: 1011 Clg: 1011 CFM50 Duct. NA Duct Leakage to Outside: 1.00 CFM @ 25 Pascals Window Data U-Factor SHGC Window. 0.340 0.300 Mechanical Equipment HEAT Fuel -fired air distribution, Natural gas, 93.5 AFUE. COOL. Air conditioner, Electric, 13.0 SEER. DHW. Conventional, Natural gas, 0.62 EF, 50.0 Gal. Builder or Design Professional Signature REM1NRate-ReSklk WE.,gygrulysaantl Rafbg Software 04.3