5609 Big Canyon Dr - Disclosures/Blower Door Test - 09/23/2013
31301SI) nergyLogic analysts. insight. answers. AIR LEAKAGE REPORT Date: September 23, 2013 Building Name: Ryland Homes Owner's Name: Ryland Homeowner Property: 5609 Big Canyon Dr Address: Ft Collins, CO80522 Builder's Name: Ryland Homes Weather Site: Ft. Collins, CO File Name: 5609 Big Canyon Dr-Ryland-REM14.3.blg Whole House Infiltration Duct Leakage Ventilation Rating No.: 28931 Rating Org.: EnergyLogic, Inc Phone No.: 970.566.6463 1.800.315.0459 Rater's Name: Justin Heldenbrand Rater's No.: 1088900 Rating Type: Confirmed Rating Date: 9/19/13 Blower door test Heating Cooling NaturalACH: 0.14 0.11 ACH @ 50 Pascals: 2.28 2.28 CFM @ 25 Pascals: 827 827 CFM @ 50 Pascals: 1298 1298 Eff. Leakage Area: [sq.in] 71.3 71.3 Specific Leakage Area: 0.00013 0.00013 ELAM00sfshell: [sq.in] 0.85 0.85 Leakage to Outside Units Main CFM @ 25 Pascals: 1 CFM25 / CFMfan: 0.0006 CFM25 / C FA: 0.0003 CFM per Std 152: N/A CFM per Std 152 / CFA: N/A CFM @ 50 Pascals: 2 Eff. Leakage Area: [sq.in] 0.09 Thermal Efficiency: N/A Total Duct Leakage Units CFM25/CFA Total Duct Leakage: 0.0276 Mechanical: Exhaust Only Sensible Recovery Eff. (%): 0.0 Total Recovery Eff. (%): 0.0 Rate (cfm): 84 Hours/Day: 21.5 Fan Watts: 15.0 Cooling Ventilation: Natural Ventilation ASHRAE 62.2 - 2010 Ventilation Requirements For this home to comply with ASHRAE Standard 62.2 - 2010 Ventilation and Acceptable IndoorAir Quality in Low -Rise Residential Buildings, a minimum of 75 cfm of mechanical ventilation must be provided continuously, 24 hours per day. Alternatively, an intermittently operating mechanical ventilation system may be used if the ventilation rate is adjusted accordingly. For example, a 150 cfm mechanical ventilation system would need to operate 12 hours per day, as long as the system operates to provide required average ventilation once each hour. REM/Rate - Residential Energy Analysis and Rating Software 04.3 This information does not constitute any warranty of energy cost or savings. 01985-2013 Arch tectural Energy Corporation, Boulder, Colorado. OnergyLogic analysis. Insight. answers. COMPONENT LOAD SUMMARY Date: September 23, 2013 Rating No.: 28931 Building Name: Ryland Homes Rating Org.: EnergyLogic, Inc Owner's Name: Ryland Homeowner Phone No.: 970.566.6463 1.800.315.0459 Property: 5609 Big Canyon Dr Rater's Name: Justin Heldenbrand Address: Ft Collins, CO80522 Raters No.: 1088900 Builder's Name: Ryland Homes Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 5609 Big Canyon Dr-Ryland-REM14.3.big Rating Date: 9/19/13 Ryland Homes HEATING SEASON (MMBtu/yr) Ceilings/Roofs 6.3 Rim/Band Joists 1.8 Above Grade Walls 20.4 Foundation Walls 12.7 Doors 0.8 Windows/Skylights 15.0 Frame Floors 1.6 Crawl Space/Unht Bsmt 0.0 Slab Floors 3.3 Infiltration 5.3 Mechanical Ventilation 11.5 Ducts 0.0 Active Solar 0.0 Sunspace 0.0 Internal Gains -20.4 Total 58.3 Ryland Homes REM/Rate - Residential Energy Analysis and Rating Software v14.3 This information does not constitute any warranty of energy cost or savings. © 1985-2013 Architectural Energy Corporation, Boulder, Colorado.