HomeMy WebLinkAbout838 Ridge Runner Dr - Disclosures/Blower Door Test - 07/29/2013612o?1,3y BUILDING LEAKAGE TEST Date of Test: 7/29/2013 Technician: Doug Groff Test File: DR Horton Blower door Customer: DR Horton Building Address: 838 Ridge Runner Drive 7600 E Orchard Rd #350-S Fort Collins, Colorado 80524 Greenwood Village, Colorado 80111 Phone Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Minneapolis Leakage Ratio: 4. Building Leakage Curve: 5. Test Settings: 1024 CFM (+/- 0.1 %) 2.67 ACH 0.39 CFM per ft2 floor area 0.17 CFM50 per ft2 surface area Flow Coefficient (C) = 771.4 ( +/- 4.0 % Exponent (n) = 0.073 ( +/- 0.010 ) Correlation Coefficient = 0.97241 Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 262.6 CFM 0.68 ACH 2. Estimated Design Infiltration Rate: Winter: 408.7 CFM 1.07 ACH Summer: 232.2 CFM 0.61 ACH 3. Recommended Whole Building Mechanical 0.0 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: �l2U�l BUILDING LEAKAGE TEST Page 2 Date of Test: 7/29/2013 Test File: DR Horton Blower door Building Conditions Inside Temperature: 77 deg F Heating Fuel: Gas Outside Temperature: 68 deg F Heating Fuel Cost: # of Stories 2.0 Heating Efficiency: Heating Degree Days: 6020 Wind Shield: M Cooling Fuel Cost: # of Occupants Cooling SEER: Cooling Degree Days: 287 # of Bedrooms: 3.0 Volume: 23012 ft3 Ventilation Weather Factor: 0.87 Surface Area: 5990 ft2 Energy Climate Factor: 17.0 Floor Area: 2627 ft2 Design Winter Wind Speed: 9.0 mph Design Winter Temp Diff: 69 deg F Design Summer Wind Speed: 7.0 mph Design Summer Temp Diff: 16 deg F Comments GARAGE WRT HOUSE: 4613a @ 5013a E 12D 713 Y 1. BUILDING LEAKAGE TEST Page 3 Date of Test: 7/29/2013 Test File: DR Horton Blower door Data Points: Data Entered Manually Nominal Temperature Building Fan Pressure Nominal Adjusted Fan Baseline Pressure (Pa) (Pa) Flow Flow % Error Configuration Std Dev (Pa) -1.2 n/a +/- 0.00 -65.0 33.3 1050 1041 -0.1 Ring A -60.0 33.0 1045 1036 -0.0 Ring A -55.0 32.6 1040 1031 0.1 Ring A -50.0 32.3 1035 1026 0.4 Ring A -45.0 31.4 1020 1011 -0.3 Ring A