HomeMy WebLinkAbout2543 Lynnhaven Ln - Disclosures/Blower Door Test - 08/20/2013BUILDING LEAKAGE TEST Thermal Concepts 6617 S. College ave Fort Collins, CO 80525 Date of Test: 8-20-13 Test File: Journey Homes 2543 Lynnhaven-BD Customer: Journey Homes Technician: Paul Higman Project Number: Greeley, CO 80634 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Building Leakage Curve: Building Address: 2543 Lynnhaven Ln Fort Collins, CO 80524 1261 CFM50 (+/- 0.3 %) 3.33 ACH50 0.4365 CFM50/ft2 floor area 125.7 in2 ( +/- 1.5 %) Canadian EgLA @ 10 Pa 65.6 in2 (+/- 2.3 %) LBL ELA @ 4 Pa Flow Coefficient (C) = 91.1 ( +/- 3.6 %) Exponent (n) = 0.672 ( +/- 0.010 ) Correlation Coefficient = 0.99939 4. Test Settings: Test Standard: CGSB Test Mode: Depressurization Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 52.8 CFM 0.14 ACH 2. Estimated Design Infiltration Rate: Winter: 83.0 CFM 0.22 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Summer: 49.0 CFM 0.13 ACH BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 8-20-13 Test File: Journey Homes 2543 Lynnhaven-BD Building Information Location Climate Information Volume 22745 Ventilation Weather Factor 0.87 SurfaceArea Energy Climate Factor 17.00 FloorArea 2888 Heating Degree Days 6020 Height 8 Cooling Degree Days 287 #of Bedrooms 3 Design Winter Wind Speed 9.0 mph #of Occupants Design Summer Wind Speed 7.0 mph Year of Construction 2013 Design Winter Temp Diff 69 deg F Wind Shield M Design SummerTemp Diff 16 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency% Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 8-20-13 Test File: Journey Homes 2543 Lynnhaven-BD Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) 67.0 66.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -0.7 n/a n/a -60.0 -59.3 60.9 1410 1409 -0.4 Ring A -55.0 -54.3 53.8 1327 1326 -0.5 Ring A -50.0 -49.3 48.3 1259 1258 0.7 Ring A -45.0 -44.3 41.7 1172 1171 0.7 Ring A -40.1 -39.4 34.9 1075 1074 -0.0 Ring A -35.3 -34.6 29.5 990 989 0.5 Ring A -30.0 -29.3 215.8 . 870 869 -1.3 Ring B -25.1 -24.4 173.1 780 779 0.1 Ring B -0.7 n/a n/a Deviations from Standard CGSB -Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 8-20-13 Test File: Journey Homes 2543 Lynnhaven-BD Comments House wrt Garage = -46.9pa � Cit'yof Planning, Development & Transportation Services Fort Coltins /"�_`�•�, Community Development & Neighborhood Services Simulated Performance Alternative (SPA) Cover Sheet `���� 1 � Submittal and Rating Type ❑Stock Plan Permit—Projected Worst-Case Rating Builder Model: 1444 ❑ Lot-specific Permit- Projected Rating Address: �Completed Home—Confirmed Rating Address: z543 Lynnhaven Ln Data Required for All SPA Ratings Builder: �ourney Homes Rating Firm: Thermal Concepts Paul Higman 8-21-13 Energy rater: Date: Duct Location In uts Location Su I Return % Area R-Vaiue % Area R-Value Inside conditioned space 100 100 Utili Rates Ener Source Service char e Rate Electricity 5 $/month �O9 $/kWh Natural gas 10 $/month 0.65 $/therm Spaces considered outside the thermal boundary: Additional Information for Stock Plan Permit— Projected Worst-Case Rating "Worst-case" configuration: Foundation type(s) Options included Orientation of front elevation ❑Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report ❑Attach REM/Rate Energy Code Inspection Checklist Additional Information for Lot-Specific Permit— Projected Rating ❑Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report ❑Attach REM/Rate Energy Code Inspection Checklist Additional Information for Completed Home —Confirmed Rating ❑Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report (Utility rates reflected in this report must be City-approved rates on lot-specific permit application date.) ❑Attach Home Energy Rating Certificate Updated 11/09/2012