HomeMy WebLinkAbout2536 Lynnhaven Ln - Disclosures/Blower Door Test - 07/25/2013BUILDING LEAKAGE TEST Thermal Concepts 6617 S. College ave Fort Collins, CO 80525 Phone: 970-223-7090 Date of Test: 7-25-13 Test File: Journey Homes 2536 Lynnhaven-BD Technician: Paul Higman ��3v �fA3y n Customer: Journey Homes Greeley, CO 80634 Phone Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Minneapolis Leakage Ratio: 4. Building Leakage Curve: 5. Test Settings: Building Address: 2536 Lynnhaven Fort Collins, CO 80524 1336 CFM (+/- 0.4 %) 2.79 ACH 0.43 CFM per ft2 floor area 133.7 in2 ( +/- 2.2 %) Canadian EgLA @ 10 Pa 69.8in2(+/-3.6%)LBLELA@4Pa 0.00 CFM50 per ft2 surface area Flow Coefficient (C) = 97.4 ( +/- 5.6 %) Exponent (n) = 0.670 ( +/- 0.015 ) Correlation Coefficient = 0.99857 Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door, S/N 9876 Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 65.7 CFM 0.14 ACH 2. Estimated Design Infiltration Rate: Winter: 88.4 CFM 0.18 ACH Summer: 52.6 CFM 0.11 ACH 3. Recommended Whole Building Mechanical 51.3 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 Date of Test: 7-25-13 Test File: Journey Homes 2536 Lynnhaven-BD . Building Conditions Inside Temperature: 74 deg F Heating Fuel: Gas Outside Temperature: 74 deg F Heating Fuel Cost: #of Stories 1.0 Heating Efficiency: Heating Degree Days: 6020 Wind Shield: M Cooling Fuel Cost: #of Occupants Cooling SEER: Cooling Degree Days: 287 ' #of Bedrooms: 2.0 Volume: 28769 ft3 Ventilation Weather Factor: 0.87 Surface Area: Energy Climate Factor: 17.0 Floor Area: 3080 ft2 Design Winter Wind Speed: 9.0 mph Design Winter Temp Diff: 69 deg F Design Summer Wind Speed: 7.0 mph Design Summer Temp Diff: 16 deg F Comments House wrt Garage=�7.5 pa House wrt Mech room = Electric water heater BUILDING LEAKAGE TEST Page 3 Date of Test: 7-25-13 Test File: Journey Homes 2536 Lynnhaven-BD � Data Points: Data Entered Manually Nominal Temperature Building Fan Pressure Nominal Adjusted Fan Baseline Pressure(Pa) (Pa) Flow Flow % Error Configuration Std Dev(Pa) -0.5 n/a +/-0.00 -60.1 70.3 1512 1512 0.5 Ring A -55.0 61.4 1416 1416 -0.1 Ring A -50.0 52.8 1315 1315 -1.1 Ring A -45.1 48.1 • 1257 1257 1.4 Ring A -40.8 39.5 1142 1142 -1.4 Ring A -35.1 33.0 1046 1046 -0.0 Ring A -30.0 27.3 953 953 1.3 Ring A -25.0 194.8 827 827 -0.5 Ring B -0.3 n/a +/-0.00