Loading...
HomeMy WebLinkAbout2531 Banbury Ln - Disclosures/Blower Door Test - 08/22/2013BUILDING LEAKAGE TEST Thermal Concepts 6617 S. College ave Fort Collins, CO 80525 Date of Test: 8-22-13 Test File: Journey Homes 2531 Banbury Ln-BD Customer: Journey Homes Technician: Project Number: Greeley, CO 80634 Building Address: 2531 Banbury Ln Fort Collins, CO 80524 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Building Leakage Curve: 4. Test Settings: 1083 CFM50 (+/- 0.7 %) 3.96 ACH50 0.6118 CFM50/ft2 floor area 98.5 in2 (+/- 3.5 %) Canadian EgLA @ 10 Pa 48.8in2(+/-5.6%)LBLELA@4Pa Flow Coefficient (C) = 62.7 ( +/- 8.8 %) Exponent (n) = 0.728 ( +/- 0.023 ) Correlation Coefficient = 0.99700 Test Standard: CGSB Test Mode: Depressurization Infiltration Estimates "I. Estimated Average Annual Infiltration Rate: 48.4 CFM 0.18 ACH 2. Estimated Design Infiltration Rate: Winter: 82.4 CFM Summer: 46.3 CFM 0.30 ACH 0.17 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: No Text No Text No Text