Loading...
HomeMy WebLinkAbout1733 Beam Reach Pl - Disclosures/Blower Door Test - 07/02/2013BUILDING LEAKAGE TEST ,W6- 1�)Ob 5t-� Date of Test: 7-2-13 Test File: Ridgeway Const 1733 Beamreach-BD Customer: Ridgeway Construction Fort Collins, CO 80524 Phone Test Results Technician: Paul Higman Building Addre 1733 Beamreach PI Fort Collins, CO 80524 1. Airflow at 50 Pascals: 874 CFM (+/- 0.4 %) (50 Pa = 0.2 w.c.) 3.16 ACH 0.25 CFM per ft2 floor area 2. Leakage Areas 3. Minneapolis Leakage Ratio: 4. Building Leakage Curve: 78.1 in2 (+/- 2.4 %) Canadian EgLA @ 10 Pa 38.2 in2(+/-3.9%) LBLELA@4Pa 0.00 CFM50 per ft2 surface area Flow Coefficient (C) = 48.4 ( +/- 6.1 %) Exponent (n) = 0.740 ( +/- 0.016 ) Correlation Coefficient = 0.99862 5. Test Settings: Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door, S/N 3316 Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 18.2 CFM 0.07 ACH 2. Estimated Design Infiltration Rate: Winter: 48.4 CFM 0.18 ACH Summer: 28.8 CFM 0.10 ACH 3. Recommended Whole Building Mechanical 65.1 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 Date of Test: 7-2-13 Test File: Ridgeway Const 1733 Beamreach-BD Building Conditions Inside Temperature: 78 deg F Heating Fuel: Gas Outside Temperature: 97 deg F Heating Fuel Cost: # of Stories 1.0 Heating Efficiency: Heating Degree Days: 6020 Wind Shield: M Cooling Fuel Cost: # of Occupants Cooling SEER: Cooling Degree Days: 287 # of Bedrooms: 3.0 Volume: 16567 ft3 Ventilation Weather Factor: 0.87 Surface Area: Energy Climate Factor: 17.0 Floor Area: 3513 ft2 Design Winter Wind Speed: 9.0 mph Design Winter Temp Diff: 69 deg F Design Summer Wind Speed: 7.0 mph Design Summer Temp Diff: 16 deg F Comments House WRT Garage =-47.8pa BUILDING LEAKAGE TEST Page 3 Date of Test: 7-2-13 Test File: Ridgeway Const 1733 Beamreach-BD Data Points: Data Entered Manually Nominal Temperature Building Fan Pressure Nominal Adjusted Fan Baseline Pressure (Pa) (Pa) Flow Flow % Error Configuration Std Dev (Pa) -1.0 n/a +/- 0.00 -59.5 28.0 965 982 -0.1 Ring A -55.9 241.1 919 935 -0.3 Ring B -50.4 205.9 850 865 -0.3 Ring B -45.1 176.3 787 801 0.3 Ring B -40.8 150.6 728 741 0.1 Ring B -35.1 124.3 662 674 2.0 Ring B -30.7 98.6 590 600 0.6 Ring B -25.8 70.0 498 507 -3.0 Ring B -0.7 n/a +/- 0.00