Loading...
HomeMy WebLinkAbout5139 Exploration Ln - Disclosures/Final Energy - 06/05/2013ri l�9so-o6s' F (9nergyLogic •p• ra �* �,s analysis. insight. answers. FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT Date: June 05, 2013 Rating No.: 27886 Building Name: Village Homes Rating Org.: EnergyLogic Inc. Owner's Name: Village Homeowner Phone No.: 970.566.6463 1.800.315.0459 Property: 5139 Exploration Ln Rater's Name: Justin Heldenbrand Address: Fort Collins, CO80528 Rater's No.: 1088900 Builders Name: Village Homes Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 5139 Exploration Ln-Village-REM14.2.big Rating Date: 5/31/13 Annual Energy Cost ($) FC 2012 As Designed Heating: 978 892 Cooling: 163 92 Water Heating: 210 210 SubTotal - Used to Determine Compliance: 1351 1194 Lights &Appliances: 998 977 Photovoltaics: -0 -0 Service Charge: 0 0 Total: 2349 2171 Mandatory Requirements: Duct Insulation R-Value Check (per Section 405.2) Minimum Duct Insulation (Design must be equal or higher) 6.0 8.0 Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.400 0.340 Home Infiltration (Section 402.4.2): Duct Leakage (Section 403.2.2): PASSES PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the requirements by 11.6%. Justin Heldenbrand Name: Justin Heldenbrand Signature: WAJ .,d 2013.06.05 07:49:19 -06'00' Organization: EnergyLogic Inc. Date: June 05, 2013 REM/Rate - Residential Energy Analysis and Rating Software v14.2 This information does not constitute any warranty of energy cost or savings. 0 1985-2013 Architectural Energy Corporation, Boulder, Colorado. FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT Village Homes Page 2 * Design energy cost is based on the following systems: Heating: Fuel -fired air distribution, 84.0 kBtuh, 93.5AFUE. Cooling: Air conditioner, 36.0 kBtuh, 13.0 SEER. Water Heating: Conventional, Gas, 0.62 EF Window -to -Floor Area Ratio: 0.10 Blower door test: Htg: 1269 Clg: 1269 CFM50 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate - Residential Energy Analysis and Rating Software v14.2 This information does not constitute any warranty of energy cost or savings. 0 1985-2013 Arch tectural Energy Corporation, Boulder, Colorado. 0 energyLogic n- www.anerOYlcglc..coiaii Rd&V &t - " olow 4������Village Homes 5139 Exploration Ln Uniform Energy Rating System Fort Collins, •:0528 �Q1t� 7tjV +5 Stars Plus Energy Efficient 1 Star 1 Star Plus 2 Stars 2 Stars Plus 3 Stars 3 Stars Plus 4 Stars 4 Stars Plus 5 Stars 5 Stars Plus 500-401 400-301 300-251 250-201 200-151 150-101 11 100-91 90-86 85-71 70 or Less HERS Index: Conditioned Area: 3933 sq. ft. HouseType: Single-family detached Conditioned Volume: 39672 cubic ft. Foundation: Conditioned basement Bedrooms: 5 Mechanical Systems Features Heating: Fuel -fired air distribution, Natural gas, 93.5AFUE. Cooling: Air conditioner, Electric, 13.0 SEER. Water Heating: Conventional, Natural gas, 0.62 EF, 50.0 Gal. Duct Leakage to Outside: 17.00 CFM. Ventilation System: Exhaust Only: 84 cfm, 15.0 watts. Programmable Thermostat: Heating: Yes Cooling: Yes Ceiling Flat: R-38 Slab: R-0.0 Edge, R-0.0 Under Sealed Attic: NA Exposed Floor: R-43 Vaulted Ceiling: NA Window Type: Low E .34 /.30 Above Grade Walls: R-13 Infiltration Rate: Htg: 1269 Clg: 1269 CFM50 Foundation Walls: R-11.0 Method: Blower door test Percent Interior Lighting: 100.00 Range/Oven Fuel: Electric Percent Garage Lighting: 0.00 Clothes Dryer Fuel: Electric Refrigerator (kWh/yr): 727.00 Clothes Dryer EF: 3.01 Dishwasher Energy Factor: 0.00 Ceiling Fan (cfm/Watt): 0.00 The Home Energy Rating Standard Disclosure for this home is available from the rating provider. REM/Rate - Residential Energy Analysis and Rating Software v14.2 This information does not constitute any warranty of energy cost or savings. O 1985-2013Architectural Energy Corporation, Boulder, Colorado. Registry to: 348335694 Rating Number: 27886 Certified Energy Rater: Justin Heldenbrand Rating Date: 5/31/13 Rating Ordered For: Village Homeowner Estimated Annual Energy Cost Confirmed Use MMBtu Cost Percent Heating 81.1 $762 38% Cooling 2.2 $67 3% Hot Water 23.5 $211 10% Lights/Appliances 31.3 $977 48% Photovoltaics -0.0 $-0 -0% Service Charges $0 0% Total 138.1 $2017 100% This home meets or exceeds the minimum criteria for all of the following: 2001 International Energy Conservation Code 2003 International Energy Conservation Code 2004 International Energy Conservation Code 2006 International Energy Conservation Code 2009 International Energy Conservation Code Home Energy Rating Provider EnergyLogic,Inc. y,• ... P.O. Box N Berthoud, CO 80513 Phone # 1-800-315-0459 T� ,%`Noe'k69&069)"�F wwwnrglogiccom 4 y K iii a° Justin Heldenbra-nd, 2013.06.05 07:49:41 -0 Certified Energy Rater