HomeMy WebLinkAbout5139 Exploration Ln - Disclosures/Final Energy - 06/05/2013ri l�9so-o6s' F
(9nergyLogic
•p• ra �* �,s
analysis. insight. answers.
FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT
Date: June 05, 2013
Rating No.:
27886
Building Name: Village Homes
Rating Org.:
EnergyLogic Inc.
Owner's Name: Village Homeowner
Phone No.:
970.566.6463 1.800.315.0459
Property: 5139 Exploration Ln
Rater's Name: Justin Heldenbrand
Address: Fort Collins, CO80528
Rater's No.:
1088900
Builders Name: Village Homes
Weather Site: Ft. Collins, CO
Rating Type:
Confirmed
File Name: 5139 Exploration Ln-Village-REM14.2.big
Rating Date:
5/31/13
Annual Energy Cost ($)
FC 2012 As Designed
Heating:
978 892
Cooling:
163 92
Water Heating:
210 210
SubTotal - Used to Determine Compliance:
1351 1194
Lights &Appliances:
998 977
Photovoltaics:
-0 -0
Service Charge:
0 0
Total:
2349 2171
Mandatory Requirements:
Duct Insulation R-Value Check (per Section 405.2)
Minimum Duct Insulation (Design must be equal or higher)
6.0 8.0
Window U-Factor Check (Section 402.5)
Window U-Factor (Design must be equal or lower):
0.400 0.340
Home Infiltration (Section 402.4.2):
Duct Leakage (Section 403.2.2):
PASSES
PASSES
This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy
Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the requirements by 11.6%.
Justin Heldenbrand
Name: Justin Heldenbrand Signature: WAJ .,d 2013.06.05 07:49:19 -06'00'
Organization: EnergyLogic Inc. Date: June 05, 2013
REM/Rate - Residential Energy Analysis and Rating Software v14.2
This information does not constitute any warranty of energy cost or savings.
0 1985-2013 Architectural Energy Corporation, Boulder, Colorado.
FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT
Village Homes
Page 2
* Design energy cost is based on the following systems:
Heating: Fuel -fired air distribution, 84.0 kBtuh, 93.5AFUE.
Cooling: Air conditioner, 36.0 kBtuh, 13.0 SEER.
Water Heating: Conventional, Gas, 0.62 EF
Window -to -Floor Area Ratio: 0.10
Blower door test: Htg: 1269 Clg: 1269 CFM50
In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed
prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set
equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software
updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards.
REM/Rate - Residential Energy Analysis and Rating Software v14.2
This information does not constitute any warranty of energy cost or savings.
0 1985-2013 Arch tectural Energy Corporation, Boulder, Colorado.
0
energyLogic
n-
www.anerOYlcglc..coiaii
Rd&V &t - "
olow
4������Village Homes
5139 Exploration Ln
Uniform Energy Rating System
Fort Collins, •:0528
�Q1t� 7tjV +5 Stars Plus
Energy Efficient
1 Star
1 Star Plus
2 Stars
2 Stars Plus
3 Stars
3 Stars Plus
4 Stars
4 Stars Plus
5 Stars
5 Stars Plus
500-401
400-301
300-251
250-201
200-151
150-101
11 100-91
90-86
85-71
70 or Less
HERS Index:
Conditioned Area:
3933 sq. ft. HouseType: Single-family detached
Conditioned Volume:
39672 cubic ft. Foundation: Conditioned basement
Bedrooms:
5
Mechanical Systems Features
Heating:
Fuel -fired air distribution, Natural gas, 93.5AFUE.
Cooling:
Air conditioner, Electric, 13.0 SEER.
Water Heating:
Conventional, Natural gas, 0.62 EF, 50.0 Gal.
Duct Leakage to Outside:
17.00 CFM.
Ventilation System:
Exhaust Only: 84 cfm, 15.0 watts.
Programmable Thermostat:
Heating: Yes Cooling: Yes
Ceiling Flat:
R-38
Slab:
R-0.0 Edge, R-0.0 Under
Sealed Attic:
NA
Exposed Floor:
R-43
Vaulted Ceiling:
NA
Window Type:
Low E .34 /.30
Above Grade Walls:
R-13
Infiltration Rate:
Htg: 1269 Clg: 1269 CFM50
Foundation Walls:
R-11.0
Method:
Blower door test
Percent Interior Lighting: 100.00 Range/Oven Fuel: Electric
Percent Garage Lighting: 0.00 Clothes Dryer Fuel: Electric
Refrigerator (kWh/yr): 727.00 Clothes Dryer EF: 3.01
Dishwasher Energy Factor: 0.00 Ceiling Fan (cfm/Watt): 0.00
The Home Energy Rating Standard Disclosure for this home is available from the rating provider.
REM/Rate - Residential Energy Analysis and Rating Software v14.2
This information does not constitute any warranty of energy cost or savings.
O 1985-2013Architectural Energy Corporation, Boulder, Colorado.
Registry to:
348335694
Rating Number:
27886
Certified Energy Rater:
Justin Heldenbrand
Rating Date:
5/31/13
Rating Ordered For:
Village Homeowner
Estimated Annual Energy Cost
Confirmed
Use
MMBtu
Cost
Percent
Heating
81.1
$762
38%
Cooling
2.2
$67
3%
Hot Water
23.5
$211
10%
Lights/Appliances
31.3
$977
48%
Photovoltaics
-0.0
$-0
-0%
Service Charges
$0
0%
Total
138.1
$2017
100%
This home meets or exceeds the minimum
criteria for all of the following:
2001 International Energy Conservation Code
2003 International Energy Conservation Code
2004 International Energy Conservation Code
2006 International Energy Conservation Code
2009 International Energy Conservation Code
Home Energy Rating Provider
EnergyLogic,Inc.
y,• ...
P.O. Box N
Berthoud, CO 80513
Phone # 1-800-315-0459 T� ,%`Noe'k69&069)"�F
wwwnrglogiccom 4 y K iii a°
Justin Heldenbra-nd,
2013.06.05 07:49:41 -0
Certified Energy Rater