HomeMy WebLinkAbout5138 Exploration Ln - Disclosures/Blower Door Test - 06/11/2013e ner Lo is
''L a analysis. insight. answers.
AIR LEAKAGE REPORT
Date: June 11, 2013 Rating No.: 28001
Building Name:
Village Homes
Rating Org.:
EnergyLogic Inc.
Owner's Name:
Village Homeowner
Phone No.:
970.566.6463 1.800.315.0459
Property:
5138 Exploration Ln
Rater's Name:
Justin Heldenbrand
Address:
Fort Collins, CO 80528
Rater's No.:
1088900
Builder's Name:
Village Homes
Weather Site:
Ft Collins, CO
Rating Type:
Confirmed
File Name:
5138 Exploration Ln-Village-REM14.2.blg
Rating Date:
6/10/13
Whole House Infiltration
Duct Leakage
Ventilation
Blower door test
Heating
Cooling
NaturalACH:
0.09
0.07
ACH @ 50 Pascals:
1.84
1.84
CFM @ 25 Pascals:
700
700
CFM @ 50 Pascals:
1098
1098
Eff. Leakage Area: [sq.in]
60.3
60.3
Specific Leakage Area:
0.00011
0.00011
ELA/100 sf shell: [sq.in]
0.75
0.75
Leakage to Outside Units
main
CFM @ 25 Pascals:
1
CFM25 / CFMfan:
0.0005
CFM25 /CFA:
0.0003
CFM per Std 152:
N/A
CFM per Std 152 / CFA:
N/A
CFM @ 50 Pascals:
2
Eff. Leakage Area: [sq.in]
0.09
Thermal Efficiency:
N/A
Total Duct Leakage Units
CFM25/CFA
Total Duct Leakage:
0.0003
Mechanical:
Exhaust Only
Sensible Recovery Eff. (%):
0.0
Total Recovery Eff. (%):
0.0
Rate (cim):
59
Hours/Day:
24.0
Fan Watts:
15.0
Cooling Ventilation:
No Ventilation
ASHRAE 62.2 - 2010 Ventilation Requirements
For this home to comply with ASHRAE Standard 62.2 - 2010 Ventilation and Acceptable IndoorAir Quality in
Low -Rise Residential Buildings, a minimum of 59 cfin of mechanical ventilation must be provided continuously,
24 hours per day. Alternatively, an intermittently operating mechanical ventilafion system may be used if the
ventilation rate is adjusted accordingly. For example, a 118 cfm mechanical ventilation system would need to
operate 12 hours per day, as long as the system operates to provide required average ventilation once each
hour.
REM/Rate - Residential Energy Analysis and Rating Software v14.2
This information does not constitute any warranty of energy cost or savings.
01985-2013Ardtdectural Energy Corporation, Boulder, Colorado.
e nergyLogic
d, NaYOYe-069
analysis. Insight. answers.
COMPONENT LOAD SUMMARY
Date: June 11, 2013
Building Name:
Village Homes
Owners Name:
Village Homeowner
Property:
5138 Exploration Ln
Address:
Fort Collins, CO80528
Builder's Name:
Village Homes
Weather Site:
Ft Collins, CO
File Name:
5138 Exploration Ln-Village-REM14.2.big
Village Homes
HEATING SEASON (MMBtu/yr)
Ceilings/Roofs
12.4
Rim/Band Joists
1.7
Above Grade Walls
23.1
Foundation Walls
11.3
Doors
1.0
Windows/Skylights
11.1
Frame Floors
0.1
Crawl Space/Unht Bsmt
0.0
Slab Floors
6.0
Infiltration
2.9
Mechanical Ventilation
9.0
Ducts
0.0
Active Solar
0.0
Sunspace
0.0
Internal Gains
-15.8
Total
62.8
Rating No.: 28001
Rating Org.:
EnergyLogic Inc.
Phone No.:
970.566.6463 1.800.315.0459
Rater's Name:
Justin Heldenbrand
Rater's No.:
1088900
Rating Type:
Confirmed
Rating Date:
6/10/13
REM/Rate - Residential Energy Analysis and Rating Software v14.2
This information does not constitute any warranty of energy cost or savings.
0 1985-2013Architectural Energy Corporation, Boulder, Colorado.
COMPONENT LOAD SUMMARY
Village Homes Page 2
Village Homes
COOLING SEASON (MMBtulyr)
Ceilings/Roofs
0.7
Rim/Band Joists
-0.2
Above Grade Walls
-1.5
Foundation Walls
-1.7
Doors
-0.1
Windows/Skylights
2.4
Frame Floors
-0.0
Crawl Space/Unht Bsmt
0.0
Slab Floors
-2.7
Infiltration
-0.2
Mechanical Ventilation
-1.1
Ducts
0.0
Active Solar
0.0
Sunspace
0.0
Internal Gains
10.4
Whole House Ventilation
0.0
Total
5.8
REMIRate - Residential Energy Analysis and Rating Software v14.2
This information does not constitute any warranty of energy cost or savings.
01985-2013Archftectural Energy Corporation, Boulder, Colorado.
Home Located @ 5138 Exploration Ln
*House Pressure WRT garage = -48.7 Pa
*House Pressure WRT mechanical room = -50 Pa
Justin Heldenbrand
Energy Rater/ Energy Auditor
QnergyLogic
04611'1... In Jpef. •m-n.
Mobile: 970.566.6463
Scheduling: 970.556.0839
Toll Free: 800.315.0459
PO Box N
525 County Rd. 8/Hwy 56
Berthoud, CO 80513
970.532.3220
Fax: 970.532.5074
www.nraloaic.com
Home Located @ 5139 Exploration Ln
*House Pressure WRT garage = -48.2 Pa
*House Pressure WRT mechanical room = -50 Pa
Justin Heldenbrand
Energy Rater/ Energy Auditor
QnergyLogic
anaiY.�. UUaM, am een.
Mobile: 970.566.6463
Scheduling: 970.556.0839
Toll Free: 800.315.0459
PO Box N
525 County Rd. 8/Hwy 56
Berthoud, CO 80513
970.532,3220
Fax: 970.532.5074
www.nrglogic.com