Loading...
HomeMy WebLinkAbout2314 Trestle Rd - Disclosures/Final Energy - 07/25/2013I FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT Date: July 25, 2013 Rating No.: Building Name: 2314 Trestle Rating Org.: Thermal Concepts Owners Name: Bartran Consrtuction Phone No.: 970-223-7090 Property: 2314 Trestle Rater's Name: Paul Higman Address: Ft Collins, CO 80525 Raters No.: 6784592 Builder's Name: Bartran Construction Weather Site: Ft Collins, CO Rating Type: Confirmed Rating File Name: Bartran 2314 Trestle -Res 4-final.blg Rating Date: 7-25-13 Annual Energy Cost ($) FC 2012 As Designed Heating: 557 536 Cooling: 109 78 Water Heating: 130 130 SubTotal - Used to Determine Compliance: 797 744 Lights & Appliances: 881 877 Photovoltaics: -0 -0 Service Charge: 204 204 Total: 1882 1825 ' Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.400 0.350 Home Infiltration (Section 402.4.2): PASSES Duct Leakage (Section 403.2.2): PASSES This home MEETS the annual energy cost requirements and verifications of Section 405 of the 2009 International Energy Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the requirements by 6.6%. Name: Paul Higman Signature: Organization: Thermal Concepts Date: July 25, 2013 P a u 1--Digitally-signed-by—.-Paul- ' Design energy cost is based on the following systems: Higman I Heating: Fuel -fired air distribution, 88.0 kBtuh, 95.OAFUE. m a n '%' ;.DN: CN Paul Higman C = US Cooling: Air conditioner, 36.0 kBtuh, 13.0 SEER. g Datth: 2013.07.25 08:43:33 - Water Heating: Conventional, Gas, 0.61 EF. �J 06'00' Window-to-FloorArea Ratio: 0.11 / Blower door test Htg: 1581 Cig: 1581 CFM50 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost Furthermore, the standard reference design HVAC system efficiencies are set REM/Rate - Residential Energy Analysis and Rating Software v12.97 This information does not constitute any warranty of energy cost or savings. 01985-2012 Architectural Energy Corporation, Boulder, Colorado. FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT 2314 Trestle Page 2 equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate - Residential Energy Analysis and Rating Software v12.97 This information does not constitute any warranty of energy cost or savings. 01985-2012 Architectural Energy Corporation, Boulder, Colorado. �`�`�M�� �C� Registry ID: _ � �` ,� , . Rating Number: w' Cerdiled Energy Rater: Paul Higman �� Ratlng Date: 7-25-13 � • 2314 Trestle Rating Ordered For: Bartran Consrtuctlon Ft Collins,CO 80525 v„*'rx;�.,�, . ;t;,�• v�.. ������ Estimated Annual Energy Cost Confirmed Rating 5 Stars Plus use MMBtu cost Percern Confrmed Rating Heatlng 88.7 $aso 2��0 Uniform Energy Rating System Energy Efficient Cooling 2.2 $58 3°0% Hot Water 20.2 $131 8/o 1 Star 1 Star Plua 2 Stars 2 Stars Plus 3 Stars 3 Stars Plus 4 Stars 4 Stars Plus 5 Stars 5 Stars Plus LightSlApplianCes 32.6 $859 50% 500-401 400-301 300-251 250-201 200-151 150-101 100-91 90-86 85-71 70 orLess photovoltalcs -0.0 $-0 -O�o HERS Index: 64 Service Chargee $204 12% �General Ir�formation Total $1713 100°� ConditionedArea: 3321 sq.ft. HouseType: Single-family detached R;, � � £ � . Conditloned Volume: 29241 cubic ft. Founda6on: Conditioned basement �` '" Bedrooms: 3 This home meets or exceeds the minimum �MechaNcal Systems Features � crReria for all of the following: _ � - 2006 Intemadonal Energy Conservadon Code Heabng: Fuel-fired air distribution,Natural gas,95.OAFUE. 2009 International Energy Conservation Code Cooling: Air conditioner,Electric,13.0 SEER. Ciry of Fort Collins Green Code 2012" Water Heating: Conventional,Natural gas,0.61 EF,50.0 Gal. Duct Leakage to Outside: 45.00 CFM. Ventilation System: Exhaust Only:63 cfm,24.0 watts. Programmable Thermostat: Headng:Yes Cooling:Yes ,,Bulltling Shell Features Ceiling Flat: R-38 Exposed Floor: R38,R-39 � Vaulted Ceiling: NA Window Type: U:0.35,SHGC:0.31 'Compliance with criteria for this program is Above Grade Walls: R-15,R-23 Infiltratlon: detertnined by the rater. Founda6on Walls: R-13.0,R-11.0 Rate: Htg:1581 Clg:1581 CFM50 Slab: R-0.0 Edge,R-0.0 Under Method: Blower door test Y " E' .; - . `=�i9ncs a�d aPPua�ce Faacu�es Digitally signed Percent Interior Lighting: 0.00 Range/Oven Fuel: Electric Masco Home Services P a u I b .�Paul Hi man Percent Exterior Lighting: 0.00 Clothes Dryer Fuel: Electric 2339 Beville Rd DN�CN = Paul Refrigeretor(kWh/yr): 575.00 Clothes Dryer EF: 3.01 Da tona Beach,FL.32119 �. � r • � Hig�ian C = US Dishwasher Energy Factor: 0.64 Ceiling Fan(cfmNVatt): 0.00 3860-304-2200 H i g m a n`�a;e: Zo,3.0�. The Home Energy Rallng Standard Disclosure for thls home is avallable from the retlng providec �/ 25408:43:52 - REM/Rate-Residentlal Energy Analysis and Rating Software v12.97 06;00� This informaGon does not constltute any warranty of energy cost or savings. �� m 1985-2012 Architectural Energy Corporatlon,Boulder,Cotorado. �