HomeMy WebLinkAbout3827 Precision Dr - Disclosures/Blower Door Test - 07/24/2013 (2)0 BUILDING LEAKAGE TEST Date of Test: 7/24/2013 Customer: Landmark Homes Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Building Leakage Curve: 4. Test Settings: Test File: Landmark 3827 Precision r BD Technician: Paul Higman Project Number: Building Address: 3827 Precision Unit C Fort Collins, CO 80528 1308 CFM50 (+/- 0.6 %) 3.95 ACH50 0.5920 CFM50/ft2 floor area 109.4 in2 ( +/- 3.2 %) Canadian.EgLA @ 10 Pa 51.7 in2 (+/- 5.1 %) LBL ELA @ 4 Pa Flow Coefficient (C) = 61.7 ( +/- 8.0 %) Exponent (n) = 0.781 ( +/- 0.021 ) Correlation Coefficient = 0.99783 Test Standard: CGSB Test Mode: Depressurization Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 54.8 CFM 0.17 ACH 2. Estimated Design Infiltration Rate: Winter: 103.0 CFM Summer: 64.6 CFM 0.31 ACH 0.19 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating 2. Estimated Cost of Air Leakage for Cooling You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 7/24/2013 Test File: Landmark 3827 Precision Dr a BD Building Information Location Climate Information Volume 19890 Surface Area Floor Area 2210 Height 20 # of Bedrooms 2 # of Occupants Year of Construction 2013 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) 9876 Default Micromanometer Energy Conservatory DG700 You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 7/24/2013 Test File: Landmark 3827 Precision Dr P.-BD Depressurization Test: Environmental Data Indoor Temperature ("F) Outdoor Temperature (°F) 78.0 98.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Building Pressure Building Pressure Pressure (Pa) (Pa) (Pa) -3.2 n/a n/a -60.2 -57.8 64.9 -55.4 -52.9 55.3 -51.7 -49.3 48.0 -44.8 -42.3 39.1 -41.0 -38.5 31.9 -35.2 -32.8 239.5 -30.6 -28.2 186.4 -24.8 -22.4 144.0 -1.7 n/a n/a None Nominal Adjusted Flow Flow Fan (cfm) (cfm) % Error Configuration 1454 1481 1.1 Ring A 1345 1370 0.1 Ring A 1255 1278 -1.2 Ring A 1136 1157 0.7 Ring A 1029 1048 -1.9 Ring A 916 933 -0.8 Ring B 809 824 -1.4 Ring B 712 725 3.9 Ring B Deviations from Standard CGSB - Test Parameters M 1 You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 7/24/2013 Test File: Landmark 3827 Precision Dr Er` BD Comments House WRT Garage = detached garage You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com)