HomeMy WebLinkAbout1100 E Elizabeth St - Applications/Mechanical - 07/09/2013Planning, Development & Transportation
281 N. College Ave P.O. Box 580
Fort Collins, CO 80524
Phone 970-416-2740 Fax 224-6134
OVER-THE-COUNTER PERMITS ONLY
This application is to be used to apply for the following permits only (check all that apply). Air Conditioning
❑ Demolition (interior non-structural) ❑ Electrical Alteration (not service change) ❑ Gas Lighter ❑ Gas Log
❑ Heating Unit ❑ Lawn Sprinkler ❑ Mobile Home replacement ❑ Roofing ❑ Sewer Line ❑ Photo -voltaic
❑ Ventilation ❑ Water Heater ❑ Water Line ❑ Wood/Pellet Stove (must be EPA certified, provide make, model and
manufacturer).
Complete all applicable Information on the application. Incomplete applications will not be accepted.
Application # 812b 35702 Date 7/9 as t3
For office use only
lob Site Address (required)
Value of Construction (labor, materials, profit)
IF44 Agjlt
r-1 l
I-'e rJ a&1, s %a4orti ao ! 7X q # 811 W. G0
Property Owner Name
Address
City/State Zip Phone
t/s
a r�rtr�ts as
Applicant Name 1�rcK ^9^
Address
City/State Zip Phone
��Ilis AI09 C !
R
2y DO- XJ-5445
Contractor
City/State Zip Phone
1�1rriQ$ aL
}Address
i`ir W�1 dt
�olete�B 5.51 V AJO -;04 - 56V
Contractor City of Ft. Collins Sales Tax
# 3860
Are you paying taxes here or by report? ❑ Here Report
Sales tax number is required by all
Are you paying with your trust account? ❑ Yes ❑ No
Is this a residential or commercial project? ❑ Residential ❑ Commercial
If residential, is it: ❑ Single Family Detached ❑ Condo/townhome (single family attached) ❑ Duplex
❑ Multifamily (apartment) ❑ Garage
If commercial, is it: ❑ Bank ❑ Bar ❑ Church ❑ Hotel/Motel L1ei Medical office ❑ Office ❑ Retail
❑ Restaurant ❑ Other (explain)
Is this building 50 years of age or more? ❑ Yes e6 If yes, you may need to contact Historic Preservation
If this is for a demolition permit, what year was the building constructed?
If prior to 1975, you wi// need an asbestos assessment to submit with this appliradon.
Description
*If lawn sprinkler/backnow preventer, must list licensed plumber. If first-time A/c, must list licensed electrician.
Subcontractors: L/st the company name or City of Ft Collins license # Electrician Plumber Mechanical d.-OA1 Roofer Other
I hereby acknowledge that I have read this application and state that the above Information is complete and correct. I agree to
comply with all requirements contained herein and city ordinances and state laws regulating building construction. I know that a
permit is not valid until it has been paid and issued.
Applicant: �������
Print Name < rJcx l 4A Signatures Date 7/9/ao%3
SUBMITTAL DATA SHEET
GUARDIANTM SERIES SPLIT SYSTEM AIR CONDITIONERS ' UARDIAN
13 SEER - R-410A -1 PHASE - 1.5 THRU 5 NOMINAL TONS TM
MODELS: GCGD18 THRU 60 C
JOB NAME: kq!6 f N1ed;rAL LOCATION: //ZO O j5L./2q�n6
PURCHASER: ORDER NO:
ENGINEER:
SUBMITTED TO: FOR: REF: APPROVAL: CONSTRUCTION:
SUBMITTED BY: DATE:
UNIT DESIGNATION: SCHEDULE NO. MODEL NO.
Cooling Performance
Total Capacity MBH
Outdoor Design Temp °F
Electrical Data
Power Supply_I_/
Compressor Ampacity, AMPS
Total Unit Ampacity AMPS
Power Input Req KW
Minimum Wire Size AWG
Overcurrent Device
O Fuses E3 Circuit Breaker
Unit Weiaht
Unit Weight LBS
f
C US I50 9001
Certified Quality
Management System
Unit
Model
Dimensions
(Inches)
Refrigerant Connection
Service Valve Size
A
B
C
Liquid
Vapor
18
28-1/4
24
24
3/8
3/4
24
28-1/4
24
24
30
28-1/4
24
24
36
28-1/4
29-1/2
29-1/2
42
30-1 /4
29-1/2
29-1/2
7/8
48
30-1/4
29-1/2
29-1/2
60
32-1/4
34
34
All dimensions are in inches and are subject to change without notice.
Overall height is from bottom of base pan to top of fan guard.
Overall length and width include screw heads.
Johnson Controls Unitary Products 504089-USD-B-0612
TABULAR DATA SHEET
GCGD SERIES SPLIT SYSTEM AIR CONDITIONERS
13 SEER - R-410A -1 PHASE -1.5 THRU 5 NOMINAL TONS
MODELS: GCGD18 THRU 60
Physical and Electrical Data
I v/
MODEL
GCGD18
S41S3(E)
GCGD24
S41S3(E)
GCGD30
S41S3(E)
GCGD36
S41S3(E)
GCGD42
I S41S4(E)
GCGD48
S41S3(E)
GCGD60
S41S4(E)
Unit Supply Voltage
208-230V, 10, 60Hz
Normal Voltage Range 1
187 to 252
Minimum Circuit Ampacity
10.0
12.4
14.7
17.9
21.5
21.1
34.5
Max. Overcurrent Device Amps
15
20
25
30
35
35
60
Min. Overcurrent Device Amps 315
15
15
20
25
25
35
Compressor Type
Rotary
Recip
Recip
Recip
Recip
Recip
Scroll
CompressorAmps
Rated Load
Locked Rotor
7.6
40
9.3
43
10.6
54
13.1
74
16
88
15.7
84
26.4
134
Crankcase Heater
No
No
No
No
No
No
No
Factory External Discharge Muffler
No
No
No
No
No
Yes
No
Factory External Check Valve
No
No
No
No
No
No
No
HS Kit Required with TXV
Yes
Yes
Yes
Yes
Yes
Yes
No
Fan Motor Amps Rated Load
0.5
0.8
1.4
1.5
1.5
1.5
1.5
Fan Diameter Inches
17.5
17.5
17.5
22.0
22.0
22.0
24.0
Rated HP
1/12
1/8
1/4
1/4
1/4
1/4
1/4
Fan Motor
Nominal RPM
1100
1075
1100
850
850
850
850
Nominal CFM
1400
1950
2050
3200
3050
2950
3400
Face Area Sq. Ft.
9.60
9.60
9.60
13.07
14.16
14.16
18.68
Coil
Rows Deep
1
1
1
1
1
1
1
Fins/Inch
23
23
23
23
23
23
23
Liquid Line Set OD (Field Installed)
3/8
3/8
3/8
3/8
3/8
3/8
3/8
Vapor Line Set OD (Field Installed)
5/8
3/4
3/4
3/4
7/8
7/8
7/8
Unit Charge (Lbs.-Oz.)
3-3
3-13
1 3-14
4-9
4-10
4-9
5-8
Charge Per Foot, Oz.
0.58
0.62
0.62
0.62
0.67
0.67
1 0.67
Operating Weight Lbs.
97
129
131
145
164
173
1 220
Models with "E" on the end of the model number have an ElectroFin® or factory approved equivalent (contact the factory for details)
coating on the outdoor coil.
1. Rated in accordance with AHRI Standard 110-2012, utilization range "A-.
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. See Hard Start Kit Accessory Installation Manual for Hard Start Kit part number for each model.
5. The Unit Charge is correct for the outdoor unit, smallest matched indoor unit, and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or
subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
Unit
Model
Dimensions
(Inches)
Refrigerant Connection
Service Valve Size
A
B
C
Liquid
Vapor
18
28-1/4
24
24
3/8
3/4
24
28-1/4
24
24
30
28-1/4
24
24
36
281/4
29-1/2
29-1/2
42
30-1/4
29-1/2
29-1/2
7/8
48
30-1/4
29-1/2
29-1/2
60
32-1/4
34
34
All dimensions are in inches and are subject to change without notice.
Overall height is from bottom of basepan to top of fan guard.
Overall length and width include screw heads.
Johnson Controls Unitary Products 879685-UTD-C-0513
FEATURES
• Small Footprint - Extremely lightweight with a compact foot-
print, it is a perfect fit for any application.
• Quality Condenser Coils - The coil is constructed of alumi-
num microchannel tubing and enhanced aluminum fins for
reduced size and increased efficiency.
• Coil Protection - Coils are protected from damage by
a sturdy polymer mesh and a coated steel wire coil guard.
• Optional Factory E-Coat - Available ElectroFin® coated coil
on select models.
• Protected Compressor - Compressors are protected inter-
nally by a high pressure relief valve and a temperature sen-
sor, and externally by the system high pressure switch. A
factory installed liquid line filter -drier further protects the
compressor against moisture and debris.
• Environmentally Friendly Refrigerant - The next genera-
tion refrigerant R-410A delivers environmentally friendly per-
formance with zero ozone depletion.
• Durable Finish - The cabinet is made of G90-equivalent pre -
painted steel, with special primer formulas and matte cham-
pagne texture to insure less fading when exposed to sun-
light. The coated steel wire fan and coil guards and pre-
treated, galvanized steel chassis components resist corro-
sion and rust creep.
• Lower Installed Cost - Installation time and costs are
reduced by easy power and control wiring connections. The
unit is factory charged for a 15-foot lineset. The small base
dimension means less space is required on the ground or
roof.
• Top Discharge -Warm air from the top mounted fan is blown
up, away from the structure and any landscaping. This allows
compact location on multi -unit applications.
• Competitive Sound Levels - The upward air flow carries the
normal operating noise away from the living area. The rigid
top panel effectively isolates any motor sound. Isolator
mounted compressor and the condenser coil muffle the nor-
mal fan motor and compressor operating sounds.
• Low Maintenance - Long life, permanently lubricated motor -
bearings need no annual servicing.
• Easy Service Access - Fully exposed refrigerant connec-
tions and a single panel covering the electrical controls make
for easy servicing of the unit.
• Secured Service Valves - Secured, re -usable service
valves are provided on both the liquid and vapor sweat con-
nections for ease of evacuating and charging.
• Agency Listed - Safety certified by CSA to UL 1995 / CSA
22.2. Performance certified to ANSI/AHRI Standard 210/240
in accordance with the Unitary Small Equipment certification
program.
WARRANTY SUMMARY*
Standard 5-Years limited parts warranty.
Standard 5-Years limited compressor warranty.
'Does not apply to 3-Phase models or internet sales.
See Limited Warranty certicate in Users Information Manual for details.
CLEARANCES
The minimum clearances shown below must be maintained
should any patio or yard improvements be done around the out-
door unit.
• 10" Clearance Coil Area
• 60" Overhead Clearance
• 18" Minimum Service Panel Access
• 24" Minimum Unit to Unit Distance
MATCHING AIR SIDE EQUIPMENT
Model No. ❑
Submittal Form No. ❑
FIELD INSTALLED ACCESSORIES
Off Cycle Timer (S1-2TD08700124)
Thermostats ❑
Blower Off Delay (S1-2FD06700224) 9(
Hard Start Kit
Low Ambient Pressure Switch
Model
Source 1 Kit numbers
18
S1-2SA06708606
24
S1-2SA06721706
30
S1-2SA06705906
36
S1-2SA06708906
42
S1-2SA06708806
48
S1-2SA06708806
60
S1-2SA06707906
Refer to Technical Guide for detailed specifications on the unit
and its accessories.
Verify the actual ratings for each specific matchup in the online
AHRI directory at www.ahridirectorv.ora at the time of sale. It is
also recommended to print the rating certificate, if needed, at
the time of sale.
Subject to change without notice. Published in U.S.A. 504089-USD-B-0612
Copyright ® 2012 by Johnson Controls, Inc. All rights reserved. Supersedes: 504089-USD-A-0309
York International Corp.
5005 York Drive
Norman, OK 73069