Loading...
HomeMy WebLinkAbout421 Toronto St - Disclosures/Air Sealing - 07/12/2013U ( v-n t aaU BUILDING LEAKAGE TEST Thermal Concepts P.O. Box 270066 Fort Collins, CO 80527 Phone: 970-223-7090 Date of Test: 7-12-13 Technician: Paul Higman Test File: Encore Homes 421 Toronto -Whitcomb -final Customer: Encore Homes Building Address: 421 Toronto St Fort Collins, CO 80524 Windsor, CO 80550 Phone Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas 3. Minneapolis Leakage Ratio: 4. Building Leakage Curve: 5. Test Settings: 1017CFM (+/-0.2%) 3.90 ACH 0.55 CFM per ft2 floor area 92.3 in2 (+/- 1.2 %) Canadian EgLA @ 10 Pa 45.6 in2 (+/- 2.0 %) LBL ELA @ 4 Pa 0.00 CFM50 per ft2 surface area Flow Coefficient (C) = 58.5 ( +/- 3.1 %) Exponent (n) = 0.730 ( +/- 0.008 ) Correlation Coefficient = 0.99963 Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door, S/N 9876 Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 48.1 CFM 0.18 ACH 2. Estimated Design Infiltration Rate: Winter: 77.1 CFM 0.30 ACH Summer: 43.8 CFM 0.17 ACH 3. Recommended Whole Building Mechanical 35.3 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 Date of Test: 7-12-13 Test File: Encore Homes 421 Toronto -Whitcomb -final Building Conditions Inside Temperature: 75 deg F Outside Temperature: 78 deg F # of Stories 2.0 Wind Shield: M # of Occupants # of Bedrooms: 2.0 Volume: 15665 ft3 Surface Area: Floor Area: 1843 ft2 Design Winter Wind Speed: 9.0 mph Design Summer Wind Speed: 7.0 mph Comments House wrt Garage =-47.5pa House wrt Mech = mechanical room is outside Heating Fuel: Gas Heating Fuel Cost: Heating Efficiency: Heating Degree Days: 6020 Cooling Fuel Cost: Cooling SEER: Cooling Degree Days: 287 Ventilation Weather Factor: 0.87 Energy Climate Factor: 17.0 Design Winter Temp Diff: 69 deg F Design Summer Temp Diff: 16 deg F BUILDING LEAKAGE TEST Page 3 Date of Test: 7-12-13 Test File: Encore Homes 421 Toronto -Whitcomb -final Data Points: Data Entered Manually Nominal Temperature Building Fan Pressure Nominal Adjusted Fan Baseline Pressure (Pa) (Pa) Flow Flow % Error Configuration Std Dev (Pa) -0.1 n/a +/- 0.00 -60.3 40.8 1159 1162 -0.2 Ring A -54.8 35.3 1080 1083 -0.3 Ring A -50.3 31.2 1018 1021 0.1 Ring A -44.3 246.4 929 932 0.2 Ring B -39.9 214.3 867 869 1.0 Ring B -35.2 175.8 786 788 0.3 Ring B -30.3 140.0 702 704 -0.0 Ring B -25.2 103.7 605 607 -1.4 Ring B -0.1 n/a +/- 0.00