HomeMy WebLinkAbout1009 Linden Gate Ct - Correspondence/Plans Approval - 05/20/2013Sarah Carter
From: Michael Missimer <Mike@fortcollinsheating.com>
Sent: Monday, May 20, 2013 2:08 PM
To: Sarah Carter
Subject: RE: Mechanical Systems Performance Report
Attachments: LP 80.pdf
Sarah
Here are the specs for the LP80. I used this fan because it can fit in a 2x4 wall. We needed to do a good wall mount fan
because the fire rating would not allow us to place a fan in the fire rated assembly without some serious restriction. The
fan is 1.1 Sones. Can we get an exception?
Thanks
Michael Missimer,
Installation/New Construction Manager
Fort Collins Heating and Air Conditioning, Inc
208 Commerce Drive #4
Fort Collins, Colorado 80524
970-484-4552<tel:970-484-4552>
"Big enough to Serve, Small enough to Care"
www.fortcollinsheating.com<http://www.fortcollinsheating.com>
From: Sarah Carter [scarter@fcgov.com]
Sent: Monday, May 20, 2013 2:25 PM
To: Michael Missimer; 'Ling Freed'
Subject: RE: Mechanical Systems Performance Report
Thanks!
saraLr cgrter t-EED` �A
Plans Analyst
City of Fort Collins
Community Development & Neighborhood Services
970-416-2748
scarter(a)fcgov.com
Tell us about our services, we want to know!
From: mike(alfortcollinsheating.com[ma iIto: mikeCalfortcolIinsheating.wm]
Sent: Monday, May 20, 2013 12:18 PM
To: Sarah Carter; 'Lina Freed'
Subject: Re: Mechanical Systems Performance Report
Sarah.
I will send the units information over to you for verification.
Mike Missimer
Fort Collins Heating and Air Conditioning
970-484-4552
----- Reply message -----
From: "Sarah Carter" <searter(a.fcgov.com>
i
To: "'Lina Freed"' <lina(aeandsco.com>, "Michael Missimer" <Mike(cDfortcollinsheating.com>
Subject: Mechanical Systems Performance Report
Date: Mon, May 20, 2013 12:11 PM
Hi Mike,
Just to clarify: On the performance report, I see all the bath fans and flow rates listed. But for the whole -dwelling unit
information, there is only one fan listed. Because this is a duplex, we need 2 whole dwelling unit fans —one in each unit.
What I told Lena is that if the fan in the second unit meets the <1 sone requirement, we can use that as the required fan
in the second unit because there is enough CFM there to satisfy the flow rate. Otherwise, I'll need information on how
the whole -dwelling ventilation requirement is being satisfied for the basement unit.
Thanks,
sarRh CRrt&r,
Plans Analyst
City of Fort Collins
Community Development & Neighborhood Services
970-416-2748
scarter()fcoov.com
Tell us about our services, we want to know!
From: Lina Freed [mailto:linaCa)eandsco.com]
Sent: Monday, May 20, 2013 12:04 PM
To: Michael Missimer
Cc: Sarah Carter
Subject: Mechanical Systems Performance Report
Good Afternoon Mike,
The City of Fort Collins has a question regarding the Mechanical Systems Performance report. It mentions one
exhaust fan in the lower unit bath, however it is my understanding we need two unless the current fan is
designed for a whole dwelling. Could you please confirm it is or isn't a whole dwelling fan?
Thank You,
Una Freed
Everitt & Schilling Company
151 West Mountain Avenue I Fort Collins, CO 80524 '
(970) 282.1352 1(877) 515.9727 Fax
** Please note I am only in the office Monday thru Thursday. **
BRMA N
MODEL LP80
LO PROFILE
VENTILATION FAN
DESCRIPTION
BLOWER:
• Plug-in, permanently lubricated motor - engineered for
continuous operation
• Dynamically balanced centrifugal blower wheel for
quiet, efficient performance
• Low RPM for quiet operation
HOUSING:
• Rugged, galvanized steel construction
• Metal, 4" oval duct connector with no metallic clatter .
• Includes 4" oval to 3" round duct reducer
• 4" height allows for 2" x 4" wall or ceiling installation
• Sturdy, easy, mounting directly to stud or joist
• Can be mounted in flat ceilings, sloped ceilings up to
12/12 pitch, and walls
GRILLE:
• Polymeric construction
• Innovative design - the result of extensive research with
designers and consumers
CONTROLS (Purchase separately):
• Refer to Broan's catalog for a complete line of
accessories to effectively adapt this fan to your
construction requirements.
U.L. Listed for use over bathtubs and showers when
connected to a GFCI protected branch circuit (ceiling
mount only).
1-Year Warranty
SPECIFICATION SHEET
TYPICAL SPECIFICATION
• Fan shall be Broan Model LP80.
• Fan shall have corrosion resistant galvanized steel housing.
It shall be ducted to a roof or wall cap using 4" or 3" round
ductwork.
• Blower assembly shall be removable, have a centrifugal -
type blower wheel and a permanently lubricated motor
designed for continuous operation.
• Metal damper/duct connector shall be included.
• Air delivery shall be no less than 80 CFM and sound level
no greater than 1.1 Sones. All air and sound ratings shall
be certified by HVI..
• Fan shall be ENERGY STAR® qualified and have an energy
efficient permanent split capacitor motor.
• Fan shall be U.L. Listed for use over bathtubs and showers
when connected to a GFCI protected branch circuit (ceiling
mount only).
® ' '
c �L US HVI
CERTIFIED
Broan-NuTone LLC Hartford, Wisconsin www.broan.com 800-558-1711
REFERENCE QTY. REMARKS Project
Location
Architect
Contractor
Submitted by Date
31A 99044965B
PERFORMANCE RATINGS
MODEL LP80 FAN
HVI PERFORMANCE
4" Duct
3" Duct
0.1 Ps - Static Pressure (inH2O)
0.25 Ps
0.1 Ps - Static Pressure (inH2O)
10.25 Ps
Airflow
(CFM)
Sound
(Sones)
Power
(Watts)
Airflow
(CFM)
Airflow
(CFM)
Sound
(Sones)
Power
(Watts)
Airflow
(CFM)
80
1.1
25.7
61
70
1.3
25.7
55.3
® . HVI-2100 CERTIFIED RATINGS comply with new testing technologies and
procedures prescribed by the Home Ventilating Institute, for off -the -shelf products,
HV' as they are available to consumers. Product performance is rated at 0.1 in. static
pressure, based on tests conducted in a state-of-the-art test laboratory. Sones are
CERTIFIED a measure of humanly -perceived loudness, based on laboratory measurements.
AMPS
Model Amps
LP80 0.3
WEIGHT
Model
Shipping
Weight
LP80
9.0lbs.
3� OVAL DUCT
�^I CONNECTOR
FOR 4" ROUND DUCT
lu
AIR FLOW PERFORMANCE
MODEL LP80 - 4" DUCT
0.7
0
= 0.5
c
2 0.4
y
0.3
a
0.2
in
0.1
0.0I ' I ' I ' I ' 1 ' 1 ' I ' I ' I ' PP' I
0 10 20 30 40 50 60 70 80 90 100
Airflow (CFM)
MODEL LP80 - 3" DUCT
0.8
0.7
N 0.6
S
0.5
in 0.2
0.0 1 I I I I I I! N
0 10 20 30 40 50 60 70 80 90
Airflow (CFM)
BRA.AWANO