HomeMy WebLinkAbout944 Ridge Runner Dr - Applications/Single Family New - 04/29/2013City of
Fort Collins
COMMUNITY DEVELOPMENT & NEIGHBORHOOD SERVICES
281 N. College Ave. - Fort Collins, CO 80524 - Phone: 970-416-2740
www.fegov.com/building
BUILDING PERMIT APPLICATION
APPLICATION NUMBER n i''�/ o%y/ APPLICATION DATE
Job Site Address
Unit # N/A
PROPERTY OWNER INFO: (All owner information is required - It Is not optional) Phone # 303-488-0061
Last name D. R. HORTON, INC. First Name Middle
Street Address 9555 S. KINGSTON CT., SUITE 200 city ENGLEWOOD State CO Zip 80112
CONTRACTOR INFO: Company Name D. R. HORTON, INC. Contractor Phone # 303-488-0061
Lic Holder Name JOSHUA VICARS City of Fort Collins License # D-590 Supervisor Cent # 3035-D1
Mailing Address 9555 S. KINGSTON CT., SUITE 200 City ENGLEWOOD State CO Zip 80112
LEGAL INFO:
Subdivision/PUDTRAIL HEAD Filing # N/A Lot Block # 3 Lot Sq Ft 15--LIA;),
CONSTRUCTION INFO: Total Building Sq Ft (not including basement)J_a�� 17j)(3 Total Garage Sq Ft
Residential Sq Ft Comm'I Sq Ft N/A # of Stories / /r 0�,
17�3 �_ Bldg Height��#Dwelling Units 1
1-' Floor Sq Ft --&C) Lp 2nd Floor Sq Ft (W 'd 31d Floor Sq Ft N/A Unfiished Bsmt Sq Ft 4
Finished Bsmt Sq Ft N/A # of Bedrooms _3 # of Full Baths (;� % Baths '/2 Baths -L- # of Fireplaces I —
Air Conditioning: YeGo9 Energy info:( Circle appropriate choice) 1. ComCheck [l 2. ResCheck w/Air Sealing 11
3. ResCheck w/Blower Door ❑ 4. Simulated Performance Alternative 6. Prescriptive w/Air Sealing 6. Prescriptive w/ Blower Door
City of Fort Collins Stock Plan # I 0 p List appropriate option #s 34 t %
UTILITIES INFO:
Water Tap Size 3/4" Sewer Tap Size 4" Metered: Yes W]No� Temp. Pedestal Yes No
Type of Heat: Fv] Gas ❑Electric Electric Main Breaker Size (Residential only) W1150 Amp or Less ❑ 200 Amp DOther
Value of Construction (including labor, material & profit) $ �1- I /) 1 _ �1��y
Description of Work: per, I 1 R� . OA-Ab,L� an A 3 oaa ea., GIObC ✓att&<Q 00n'k'q
Contact Name & Phone # of JOBSITE SUPERVISOR: SHANE SENA 303-720-4616
Subcontractor Info:
Electrical ECI, INC.
Framer K & L
Solar
Mechanical FOUR SEASONS - COBB
Plumbing JOHNSON & SONS
Roofing CAMPBELL BEARD Concrete FALCON CONCRETE Fireplace AMI
Other
Other
Other
Applicant: I hereby acknowledge that I have read this application and state that the above information is correct and agree to comply with all requirements
contained herein and City of Fort Collins ordinances nd state laws regulating building construction.
/�Z 11
IRU
Applicant Signaturdl� Print Namey�LTlrvf A•F l'Z U-1'1A. lC)- Phone 303-754-, 314CK
e/�j (Dis I bution: ite-Office Yellow -Applicant Pink -VNMN/Stormwater
THIS APPLICATION EXPIRES 180 DAYS FROM APPLICATION DATE
%,ice csi'
updated 1-31-2012
Fort Collins Planning, Development & Transportation Services
Community Development & Neighborhood Services
2012 FORT COLLINS RESIDENTIAL ENERGY CODE COMPLIANCE FORM
FORM 1 - NON -ELECTRIC NEAT (If using elec heat form 3 must be used), use this form
foj
single family houses, duplex. townhouses, or multi -family up to 3 stories.
Permit Number:
Address:
DIRECTIONS: Place a check next to Prescriptive, UA, or SPA indicating the path chosen. An air
tightness Blower Door Test is required and must pass a 4 ACH leakage max.
(A)PRESCRIPTIVE compliance for house, 2009 IRC, section N1102.1, climate zone 5.
BUILDING ENVELOPE
INSULATION R-VALUE
-
Wood frame wall insul r-value
R-20 or 13+5ci
Metal frame wall insul r-value
R-13+9ci or R-19+8
Crawl space wall
R-13 or R-10ci
Roof insulation in attic
R-38
Roof rafter insulation
R-30
Walls below grade
R-13 / R-loci
Wood floor over un-cond
R-30
Slab on grade floor, unheat
R-10, 24" DEEP
Windows
U-35
I I(B)TOTAL UA ALTERNATIVE (ResCheck), 2009 IRC, SECTION N1102.1.3
Submit a passing UA calculation (i.e. ResCheck) using 2009 IRC/IECC. The rating must be submitted at time of
application and must include address of residence; name of Individual completing the rating form; name & version
of software tool (i.e. ResCheck).
(C)SIMULATED PERFORMANCE ALTERNATIVE,. 2009 IECC, SECTION 405
energy rating system must be utilized using approved. computer software tool such as the new modified Fort
lins version of RemRate. A preliminary rating passing the 2009 IECC must be submitted at time of application.
:ing must include Address, Name of individual completing the rating,& Name & version of software tool. Final
no reauires a blower door test. Final passing rating must be submitted for certificate of occupancy.
SIGN:
DATE:
CONTRACTOR: DID f' e v^
PHONE: 303: 4�8-GU6
DO