Loading...
HomeMy WebLinkAbout5127 Exploration Ln - Disclosures/Air Sealing - 05/14/2013QnergyLogic 't Ma�y9Yboaf F a analysis. insight. answers. AIR LEAKAGE REPORT Date: May 14, 2013 Building Name: Village Homes Owner's Name: Village Homeowner Property: 5127 Exploration Ln Address: Fort Collins, CO 80528 Builder's Name: Village Homes Weather Site: Ft. Collins, CO File Name: 5127 Exploration Ln-Village-REM14.2.big Whole House Infiltration Duct Leakage Ventilation Rating No.: 27787 Rating Org.: EnergyLogic Inc. Phone No.: 970.566.6463 1.800.315.0459 Rater's Name: Justin Heldenbrand Rater's No.: 1088900 Rating Type: Confirmed Rating Date: 5/10/13 Blower door test Heating Cooling NaturalACH: 0.13 0.10 ACH @ 50 Pascals: 2.05 2.05 CFM @ 25 Pascals: 864 864 CFM @ 50 Pascals: 1355 1355 Eff. Leakage Area: [sq.in] 74.4 74.4 Specific Leakage Area: 0.00013 0.00013 ELA/100sfshell: [sq.in] 0.861 0.86 Leakage to Outside Units main CFM @ 25 Pascals: 17 CFM25 / CFMfan: 0.0093 CFM25 / CFA: 0.0043 CFM per Std 152: N/A CFM per Std 152 / CFA: N/A CFM @ 50 Pascals: 27 Eff. Leakage Area: [sq.in] 1.46 Thermal Efficiency: N/A Total Duct Leakage Units CFM25/CFA Total Duct Leakage: 0.0310 Mechanical: Exhaust Only Sensible Recovery Eff. (%): 0.0 Total Recovery Eff. (%): 0.0 Rate (cfm): 77 Hours/Day: 24.0 Fan Watts: 15.0 Cooling Ventilation: Natural Ventilation ASHRAE 62.2 - 2010 Ventilation Requirements For this home to comply with ASHRAE Standard 62.2 - 2010 Ventilation and Acceptable IndoorAir Quality in Low -Rise Residential Buildings, a minimum of 77 cfm of mechanical ventilation must be provided continuously, 24 hours per day. Alternatively, an intermittently operating mechanical ventilation system may be used if the ventilation rate is adjusted accordingly. For example, a 154 cfm mechanical ventilation system would need to operate 12 hours per day, as long as the system operates to provide required average ventilation once each hour. REM/Rate - Residential Energy Analysis and Rating Software v14.2 This information does not constitute any warranty of energy cost or savings. 01985-2013Archftectural Energy Corporation, Boulder, Colorado. 9nergyLogic Na-1988088 analysis. Insight. answers. COMPONENT LOAD SUMMARY Date: May 14, 2013 Rating No.: 27787 Building Name: Village Homes Rating Org.: EnergyLogic Inc. Owner's Name: Village Homeowner Phone No.: 970.566.6463 1.800.315.0459 Property: 5127 Exploration Ln Rater's Name: Justin Heldenbrand Address: Fort Collins, CO80528 Rater'sNo.: 1088900 Builder's Name: Village Homes Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 5127 Exploration Ln-Village-REM14.2.big Rating Date: 5/10/13 Village Homes HEATING SEASON (MMBtu/yr) Ceilings/Roofs 7.6 Rim/Band Joists 1.8 Above Grade Walls 30.8 Foundation Walls 12.8 Doors 1.0 Windows/Skylights 15.5 Frame Floors 2.1 Crawl Space/Unht Bsmt 0.0 Slab Floors 3.2 Infiltration 5.6 Mechanical Ventilation 11.7 Ducts 1.2 Active Solar 0.0 Sunspace 0.0 Internal Gains -20.7 Total 72.7 Village Homes REM/Rate - Residential Energy Analysis and Rating Software v14.2 This information does not constitute any warranty of energy cost or savings. 01985-2013 Architectural Energy Corporation, Boulder, Colorado. Home Located @ 5127 Exploration Ln *House Pressure WRT garage = -48.3 Pa *House Pressure WRT mechanical room = -50 Pa Justin Heldenbrand Energy Rater/ Energy Auditor QnergyLogic asalldU M.Igh'.' anwau. Mobile: 970.566.6463 Scheduling: 970.556.0839 Toll Free: 800.315.0459 PO Box N 525 County Rd. 8/Hwy 56 Berthoud, CO 80513 970.532.3220 Fax: 970.532.5074 www.nrglooic.com