HomeMy WebLinkAbout5127 Exploration Ln - Disclosures/Air Sealing - 05/14/2013QnergyLogic
't Ma�y9Yboaf F
a analysis. insight. answers.
AIR LEAKAGE REPORT
Date: May 14, 2013
Building Name:
Village Homes
Owner's Name:
Village Homeowner
Property:
5127 Exploration Ln
Address:
Fort Collins, CO 80528
Builder's Name:
Village Homes
Weather Site:
Ft. Collins, CO
File Name: 5127 Exploration Ln-Village-REM14.2.big
Whole House Infiltration
Duct Leakage
Ventilation
Rating No.: 27787
Rating Org.:
EnergyLogic Inc.
Phone No.:
970.566.6463 1.800.315.0459
Rater's Name:
Justin Heldenbrand
Rater's No.: 1088900
Rating Type: Confirmed
Rating Date: 5/10/13
Blower door test
Heating
Cooling
NaturalACH:
0.13
0.10
ACH @ 50 Pascals:
2.05
2.05
CFM @ 25 Pascals:
864
864
CFM @ 50 Pascals:
1355
1355
Eff. Leakage Area: [sq.in]
74.4
74.4
Specific Leakage Area:
0.00013
0.00013
ELA/100sfshell: [sq.in]
0.861
0.86
Leakage to Outside Units
main
CFM @ 25 Pascals:
17
CFM25 / CFMfan:
0.0093
CFM25 / CFA:
0.0043
CFM per Std 152:
N/A
CFM per Std 152 / CFA:
N/A
CFM @ 50 Pascals:
27
Eff. Leakage Area: [sq.in]
1.46
Thermal Efficiency:
N/A
Total Duct Leakage Units
CFM25/CFA
Total Duct Leakage:
0.0310
Mechanical:
Exhaust Only
Sensible Recovery Eff. (%):
0.0
Total Recovery Eff. (%):
0.0
Rate (cfm):
77
Hours/Day:
24.0
Fan Watts:
15.0
Cooling Ventilation:
Natural Ventilation
ASHRAE 62.2 - 2010 Ventilation Requirements
For this home to comply with ASHRAE Standard 62.2 - 2010 Ventilation and Acceptable IndoorAir Quality in
Low -Rise Residential Buildings, a minimum of 77 cfm of mechanical ventilation must be provided continuously,
24 hours per day. Alternatively, an intermittently operating mechanical ventilation system may be used if the
ventilation rate is adjusted accordingly. For example, a 154 cfm mechanical ventilation system would need to
operate 12 hours per day, as long as the system operates to provide required average ventilation once each
hour.
REM/Rate - Residential Energy Analysis and Rating Software v14.2
This information does not constitute any warranty of energy cost or savings.
01985-2013Archftectural Energy Corporation, Boulder, Colorado.
9nergyLogic
Na-1988088
analysis. Insight. answers.
COMPONENT LOAD SUMMARY
Date: May 14, 2013 Rating No.: 27787
Building Name:
Village Homes
Rating Org.:
EnergyLogic Inc.
Owner's Name:
Village Homeowner
Phone No.:
970.566.6463 1.800.315.0459
Property:
5127 Exploration Ln
Rater's Name:
Justin Heldenbrand
Address:
Fort Collins, CO80528
Rater'sNo.:
1088900
Builder's Name:
Village Homes
Weather Site:
Ft. Collins, CO
Rating Type:
Confirmed
File Name:
5127 Exploration Ln-Village-REM14.2.big
Rating Date:
5/10/13
Village Homes
HEATING SEASON (MMBtu/yr)
Ceilings/Roofs
7.6
Rim/Band Joists
1.8
Above Grade Walls
30.8
Foundation Walls
12.8
Doors
1.0
Windows/Skylights
15.5
Frame Floors
2.1
Crawl Space/Unht Bsmt
0.0
Slab Floors
3.2
Infiltration
5.6
Mechanical Ventilation
11.7
Ducts
1.2
Active Solar
0.0
Sunspace
0.0
Internal Gains
-20.7
Total
72.7
Village Homes
REM/Rate - Residential Energy Analysis and Rating Software v14.2
This information does not constitute any warranty of energy cost or savings.
01985-2013 Architectural Energy Corporation, Boulder, Colorado.
Home Located @ 5127 Exploration Ln
*House Pressure WRT garage = -48.3 Pa
*House Pressure WRT mechanical room = -50 Pa
Justin Heldenbrand
Energy Rater/ Energy Auditor
QnergyLogic
asalldU M.Igh'.' anwau.
Mobile: 970.566.6463
Scheduling: 970.556.0839
Toll Free: 800.315.0459
PO Box N
525 County Rd. 8/Hwy 56
Berthoud, CO 80513
970.532.3220
Fax: 970.532.5074
www.nrglooic.com