HomeMy WebLinkAbout834 Crooked Creek Way - Disclosures/Air Sealing - 03/28/2013p.5 Air Leakage Property Shadow Creek 834 Crooked Creek Way Fort Collins, CO 80525 Weather.Denver, CO Plan it 1625 834 Crooked Creek Way.blg Whole House Infiltration Organization Burgess Inc. 303-300-4527 Robert Hutchinson Builder Shadow Creek Homes Natural ACH ACH @ 50 Pascals CFM @ 25 Pascals CFM @ 50 Pascals Eff. leakage Area (sq.in) Specific Leakage Area ELA/ 100 sf shell (sq.in) Duct Leakage Leakage to outside Units CFM ® 25 Pascals CFM25 / CFMfan CFM25 I CFA CFM per Std 152 CFM per Std 152 / CFA CFM @ 50 Pascals Eff. Leakage Area (sq.in) Thermal Efficiency Total Duct Leakage Units Total Duct Leakage Ventilation Mechanical Sensible Recovery Eff. Total Recovery Eff. (%) Rate (cfm) Hours/Day Fan Watts Cooling ventilation BURGESS HERS Projected Rating 3/28/2013 Rating No: Worst case CONSTRUCTION scenario CONSULTANTS Rater ID:7479033 TINC SINCE IM Blower Door Test Heating I Cooling 0.11 'I 2.50 0.09 i .2.50I 762! 762I 1195 1195 65.6I 65.6, 0.00014I 0.000141 0.92, .0.92I Hvac ` O.000D� I N/A � N/A 0 I 0.00 i N/A i CFM25/CFAI 0.05381 Exhaust Only (�) O.D 0.0 55 24.0 11.3 Natural Ventilation ASHRAE 62.2 - 2010 Ventilation Requirements For this home to comply with ASHRAE Standard 62.2 _2010 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings, a minimum of 55 cfm of mechanical ventilation must be provided continuously, 24 hours per day. Alternatively, an intermittently operating mechanical ventilation system may be used if the ventilation rate is adjusted ctesgto proFor example, a log cfm mechanical ventflation system would need to operate 12 hours per day, as Long as the system oPera average ventilation once each hour. REM/Rate - Residential Energy Analysis and Rating Software v14.2 This information does not constitute any warrantyonto r savings. ®1985.2013 Architectural Energy Corporation, Boulder, p.1 BUILDING LEAKAGE TEST Date of Test: 5/1012013 Test File: Shadow Creek Blower Door Customer: Shadow Creek Homes 7600 E. Orchard Road Greenwood Village, Colorado 80111 Phone Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: S. Minneapolis Leakage Ratio: 4. Building Leakage Curve: 5. Test Settings: Technician: Doug Groff Building Address: 834 Crooked Creek Fort Collins, Colorado 80525 1194CFM(+/-0.20/6) 2.50 ACH 0.37 CFM per ft2 floor area 270.5 In2 ( +1- 1.9 %) Canadian EgLA @ 10 Pa 225.0 in2 ( +1- 2.9 °/,) LBL ELA @ 4 Pa 0.17 CFM50 per t12 surface area Flow Coefficient (C) = 634.2 (+f- 4.5 %) Exponent (n) = 0.162 ( +/- 0.011 ) Correlation Coefficient = 0.99298 Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: 9 3. Recommended Whole Building Mechanical Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 54.6 CFM 0 p.2 BUILDING LEAKAGE TEST Page 2 Date of Test: 5I10)2013 Test File: Shadow Creek Blower Door Building Conditions Inside Temperature: 64 61 deg F g Heating Fuel Cost: Outside Temperature: # of Stories 1.0 Healing Efficiency: Heating Degree Days: Wind Shield: M Cooling Fuel Cost: Cooling SEER: # of occupants Cooling Degree Days: # of Bedrooms: 2.0 28665 ft3 Ventilation Weather Factor: Volume: Surface Area: 7106 ft2 Energy Climate Factor: Floor Area: 3215 ft2 Design Winter` Wind Speed: Design Winter Temp Diff: Design Summer Temp Diff: Design Summer Wind Speed: Comments Garage WRT House: 47.5 PA @ 50 PA Gas a p.3 BUILDING LEAKAGE TEST Page 3 Date of Test: 5/10/2013 Test file: Shadow Creek Blower Door Data Points: Data Entered Manually Nominal Nominal Temperature Adjusted Fan Baseline Building Fan Pressure Flow Flow % Error Configuration Std Dev (Pa) Pressure (Pa) (Pa) +/- 0.00 -0.2 -65.0 nla 47.2 1245 1241 -0.3 Ring A Ring A 60.0 46.4 1235 1231 1216 0.2 0.4 RingA -55.0 45.3 43.4 1220 1195 1192 -0.1 Ring A 50.0 =45.0 41.9 1175 1172 0.1 Ring A `1(3 G G -L7 W