Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1027 Campfire Dr - Disclosures/Final Energy - 04/26/2013
BURGESS .9 CONS'.RUCTON COOSUI'I'ANTS IhL. FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT Date: April 26, 2013 Rating No.: Building Name: 5000 Series 2125 Rating Org.: BCCI-Burgess Inc. Owner's Name: DR Horton Phone No.: 303-300-4527 Property: 1027 Campfire Drive Rater's Name: Robert Hutchinson Address: Fort Collins, CO80524 Rater'sNo.: 7479033 Builder's Name: DR Horton Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 1027 Campfire Drive.blg Rating Date: 4/24/2013 Annual Energy Cost ($) FC 2012 As Designed Heating: 461 480 Cooling: 95 76 Water Heating: 124 124 SubTotal - Used to Determine Compliance: 681 680 Lights & Appliances: 758 745 Photovoltaics: -0 -0 Service Charge: 204 204 Total: 1643 1629 ` Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.400 0.340 Home Infiltration (Section 402.4.2): PASSES Duct Leakage (Section 403.2.2): PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses thts by 0.1%. Name: Robert Hutchinson Signature: A/ �,� 7479033 Organization: BCCI-Burgess Inc. Date: Apr 26, 2013 Design energy cost is based on the following systems: Heating: Fuel -fired air distribution, 80.0 kBtuh, 92.0 AFUE. Cooling:Airconditioner, 48.0 kBtuh, 13.0 SEER. Water Heating: Conventional, Gas, 0.62 EF. Window -to -Floor Area Ratio:0.10 REM/Rate -Residential Energy Analysis and Rating Software v14.2 This information does not constitute any warranty of energy cost or savings. ©1985-2013Architectural Energy Corporation, Boulder, Colorado. FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT 5000 Series 2125 Page 2 Blowerdoortest: Htg: 1170 Clg: 1170 CFM50 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed priorto calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate -Residential Energy Analysis and Rating Software v14.2 This information does not constitute any warranty of energy cost or savings. ©1985-2013Architectural Energy Corporation, Boulder, Colorado. BURGESS Savo Ra °� 5000 Series 2125 C Campfire Drive Fortort Collins,CCO 80524 CONSTRUCTION CONSULTANTS 'i C INC. SINCE 19S6 5 Stars Plus Confirmed Uniform Energy Rating System Energy Efficient 1 Star 1 Star Plus 2 Stars 1 2 Stars Plus 1 3 Stars 1 3 Stars Plus 1 4 Stars 1 4 Stars Plus 5 Stars 5 Stars Plus 500-401 400-301 300-251 250-201 200-151 150-101 100-91 90-86 85-71 70 or Less HERS Index: Conditioned Area: 3088 sq. ft. Conditioned Volume: 26024 cubic ft. Efficient Home Comparison: 36% Better HouseType: Single-family detached Foundation: Conditioned basement Bedrooms: 3 fechanical Systems Features Heating: Fuel -fired air distribution, Natural gas, 92.OAFUE. Cooling: Air conditioner, Electric, 13.0 SEER. Water Heating: Conventional, Natural gas, 0.62 EF, 50.0 Gal. Duct Leakage to Outside: 0.00 CFM. Ventilation System: Exhaust Only: 61 cfm, 11.3 watts. Programmable Thermostat: Heating: Yes Cooling: Yes Ceiling Flat: R-38 Slab: R-0.0 Edge, R-0.0 Under Sealed Attic: NA Exposed Floor: R-30 Vaulted Ceiling: NA Window Type: Double -Vinyl 3530""""""' Above Grade Walls: R-15 Infiltration Rate: Htg: 1170 Clg: 1170 CFM50 Foundation Walls: R-11.0 Method: Blower door test Lights and Appliance Features Percent Interior Lighting: 15.00 Range/Oven Fuel: Natural gas Percent Garage Lighting: 0.00 Clothes Dryer Fuel: Natural gas Refrigerator (kWhtyr): 775.00 Clothes Dryer EF: 2.67 Dishwasher Energy Factor: 0.68 Ceiling Fan (cfm/Watt): 0.00 The Home Energy Rating Standard Disclosure for this home is available from the rating provider. REM/Rate - Residential Energy Analysis and Rating Software v14.2 This information does not constitute any warranty of energy cost or savings. ©1985-2013 Architectural Energy Corporation, Boulder, Colorado. Registry ID: 150165672 Rating Number: Certified Energy Rater: Robert Hutchinson Rating Date: 4/24/2013 Rating Ordered For: DR Horton Estimated Annual Energy Cost Confirmed Use MMBtu Cost Percent Heating 59.2 $410 27% Cooling 2.2 $59 4% Hot Water 19.2 $125 8% Lights/Appliances 33.2 $745 48% Photovoltaics -0.0 $-0 -0% Service Charges $204 13% Total 113.8 $1542 100% This home meets or exceeds the minimum criteria for all of the following: EPA ENERGY STAR Version 2 Home 2006 International Energy Conservation Code 2009 International Energy Conservation Code s yMORTWGf/ Burgess ConstructionConsu@ants r` D+" a 101 W. Renner Road, Suite 400 2� per. Richardson, TX 75082r1' 214-888-7300 No 98-144 A¢' 214-888-7266 7479033 CCAEDITAT DN{ .441 Certified Energy Rater