Loading...
HomeMy WebLinkAbout2600 Forecastle Dr - Disclosures/Final Energy - 02/22/2013' NASCID Contractor Services FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT Date: February 22, 2013 Rating No.: Building Name: 2600 Forecastle Dr Rating Org.: Thermal Concepts Owner's Name: Journey Homes Phone No.: 970-223-7090 Property: 2600 Forecaslte Dr Rater's Name: Paul Higman Address: Fort Collins, CO 80524 Rater's No.: 6784592 Builder's Name: Journey Homes Weather Site: Ft. Collins, CO Rating Type: Confirmed Rating File Name: Journey Homes 2600 Forecastle Dr-1540-final.blg Rating Date: 1-31-13 Annual Energy Cost ($) FC 2012 As Designed Heating: 471 472 Cooling: 124 65 Water Heating: 342 338 SubTotal - Used to Determine Compliance: 937 875 Lights & Appliances: 804 793 Photovoltaics: -0 -0 Service Charge: 198 198 Total: 1938 1866 Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.400 0.342 Home Infiltration (Section 402.4.2): PASSES Duct Leakage (Section 403.2.2): PASSES This home MEETS the annual energy cost requirements and verifications of Section 405 of the 2009 International Energy Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the requirements by 6.6%. Name: Paul Higman Signature: Organization: Thermal Concepts Date: February 22, 2013 -- . -. Digitally si 3ned by: Paul ,i" Higman "Design energy cost is based on the following systems: ,> ' ', DN: CN = Paul Higman Heating: Fuel -fired air distribution, 58.0 kBtuh, 92.1 AFUE. C =ADO =Thermal Concepts Water Heating: Conventional, Elec, 0.95 EF. i g � a n Date: 2013.02.22 08:05: Cooling: Air conditioner, 14.4 kBtuh, 13.0 SEER. Signature y, ss-0�'00' Window -to -Floor Area Ratio: 0.10 I am not verified! `� t o �Ss document author a REM/Rate - Residential Energy Analysis and Rating Software v12.97 This information does not constitute any warranty of energy cost or savings. ©1985-2012 Architectural Energy Corporation, Boulder, Colorado. FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON-ELECTRIC-HEAT 2600 Forecastle Dr Page 2 Blower door test: Htg: 1112 Clg: 1112 CFM50 In accordance with IECC; building inputs,such as setpoints,infiltration rates,and window shading may have been changed prior to calculating annual energy cost. Furthermore,the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change,and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REMIRate-Residential Energy Analysis and Rating Software v12.97 This infortnafion does not constitute any warranty of energy cost or savings. OO 1985-2012 Architectural Energy Corporation,Boulder,Colorado. �`������� �C�� Registry ID: , Rating Number: � Certified Energy Rater: Paul Higman 2600 Forecastle Dr � Rating Date: 1-31-13 �'1�CQ 2600 Forecaslte Dr Rating Ordered For: Joumey Homes ' C011tl'8Ct01' Fort Collins,CO 80524 S£IV[CCS ��� � , � �� Estimated Annual EnergyCost _ '� ����� � � Confirmed Rating 5 Stars Plus use mmst� cosc Percent Confirmed Rating Heating so.s $ao2 2s�io Uniform Energy Radng System Energy Efficient Cooling 0 $0 0% Hot Water 13.3 $337 20% 1 Star 1 Star Plus 2 Stars 2 Stars Plus 3 Stars �3 Stars Pius 4 Stars I 4 Stars Plus 5 Stars 5 Stars Plus Lights/Appliances 31.3 $790 46% 500-401 400-301 300-251 250-201 200-151 150-101 100-91 90-86 85-71 70 or Less photovoltaics -0.0 $-0 ` -0% HERS Index: 69 Service Charges $198 11% General Informafion �� �,�,� = 4e' Total $1727 100% Conditioned Area: 3080 sq.ft. HouseType: Single-family detached ��_ �� Conditioned Volume: 30964 cubic ft. Foundation: Conditioned basement -- - Bedrooms: 3 This home meets or exceeds the minimum MecBanical SystemsjFeatures criteria for all of the following: 2006 Intemational Energy Conservation Code Heating: Fuel-fired air distribution, Natural gas,92.1 AFUE. 2009 Intemational Energy Conservation Code Water Heating: Conventional, Electric,0.95 EF,50.0 Gal. City of Fort Collins 2012 Green Code" Duct Leakage to Outside: 28.00 CFM. Ventilation System: Exhaust Only:54 cfm,24.0 watts. Programmable Thermostat: Heating:Yes Cooling: No Building Shell�Features °�"�� �`�� Ceiling Flat: R-38 Exposed Floor: R-38 Vaulted Ceiling: NA Window Type: U:0.34,SHGC:0.31 "Compliance with criteria for this program is Above Grade Walls: R-15 Infiltration: determined by the rater. Foundation Walls: R-0.0, R-11.0, R-8.0 Rate: Htg: 1112 Clg: 1112 CFM50 Slab: R-0.0 Edge, R-0.0 Under Method: Blower doortest Li hts and A liance Features ' o�yicairy si9ned 9 RP —� � - -� f�: by:Pau� Percent Interior Li htin 10.00 Ran e/Oven Fuel: Electric � H�9man 9 9 9 Masco Home Services i DN:CN=Paul Percent Exterior Li htin 0.00 Clothes Dr er Fuel: Electric � ' P a u.l � Higman C= 9 9 Y 2339 Beville Rd � % � { ' A�o= Refrigerator(kWh/yr): 597.00 Clothes Dryer EF: 3.01 Daytona Beach, FL. 32119 /� ' ' rnermai � f Concepts Dishwasher Energy Factor: 0.64 Ceiling Fan(cfmlWatt): 0.00 386-304-2200 Signatu � I g ��Date:2013.02. �., \y`� , � zz os:os:zo- The Home Energy Rating Standard Disclosure for this home is available from the rating provider. fe nOt o7'00' + Reason:I am REM/Rate-ResidentialEnergyAnalysisandRatlngSoftwarev72.97 verified! �� r mea�moror This infortnation does not constitute any warranty of energy cost or savings. t, / mis document O 1985-2012 Architectural Energy Corporation,Boulder,Colorado. V